HomeMy WebLinkAbout200708816_440_KT_Y07-E2_0.pdf ELECTRICAL LEGEND F KEY NOTES C SERVICE ENTRANCE EQUIPMENT ELEVATION E SINGLE LINE DIAGRAM B PNL. "D" TO LOCAL PHONE SERVICE T.T.B. OFFICE (2) 2"C-4 #3/0 & 800A BUS, 120/208V, 3Ø, 4W CU 22KAIC400AT 3P 200AT 125AT 3P 3P PNL. PNL. 1 #6 ISOL. GND 2"C-4 #3/0 & 1 #6 CU BOND & 1 #6 CU BOND 3P 150AT 2"C-4 #1/0 & "A" "B" "H" 1 #3 CU BOND IN EACH 1-1/4"C-4 #3 & 3P 100ATPNL.1 #8 CU BOND "MSB" INSTALL 120/208V/3Ø/4W/800A, CURRENT TRANSFORMER (CT) CAN AND METER SOCKET PER SERVING UTILITY COMPANY SPECIFICATIONS. ELECTRICAL SERVICE SHALL BE 800 AMP, 120/208V, 3Ø, 4W. SINGLE POINT GROUND 3/4"C-1 #3/0 CU BOND TO COLD WATER PIPE PER N.E.C. ARTICLE 250.52 (A) (1) AND 250.53 (D) 3/4"C-1 #3/0 CU GND PER N.E.C. ARTICLE 250.66 1 #3/0 CU EQUIP. BOND PER N.E.C. ARTICLE 250.92 #6 CU TO "MSB" GND BUS GENERAL NOTES D 562431 WIRE ISOLATED GROUND TO ISOLATION GROUND BUS IN PANEL AND LAND ISOLATED GROUND TO SINGLE POINT GROUND. "DO NOT COMBINE COMMON GND TO ISOLATED GROUND". 6 BUILDING MAIN DISCONNECT FOR THIS SERVICE: (MAXIMUM 6 MAINS PER N.E.C) LABEL EACH MAIN BREAKER AS INDICATED: "MAIN 1 OF 6" (ENGRAVED LETTERS x 3/4" HIGH) "MAIN 2 OF 6" "MAIN 3 OF 6" "MAIN 4 OF 6" "MAIN 5 OF 6" "MAIN 6 OF 6" CIRCUIT BREAKER #5 IN THE SWITCHBOARD SHALL BE 100A PANEL "H" SHUNT TRIP BREAKER CONTROLLED BY HOOD'S FIRE EXTINGUISHER SYSTEM. IF QMB BOARD IS USED, PROVIDE MAIN SHUNT TRIP BREAKER (SAME SIZE) IN PANEL "H". PROVIDE 2" CONDUIT STUBBED INTO BUILDING FROM LATERAL POLE FOR TELEPHONE. VERIFY AVAILABLE FAULT CURRENT AT SERVICE ENTRANCE WITH THE UTILITY CO. AND PROVIDE "AIC" RATING AS REQUIRED. (3) 5/8" DIA. x 10'-0" COPPER CLAD GROUND RODS. INSTALL 10'-0" APART AND CONNECT GROUND SYSTEM PER N.E.C ARTICLE 250. INSTALL UNDERGROUND SERVICE LATERAL TO UTILITY TRANSFORMER PER SERVING UTILITY COMPANY SPECIFICATIONS. (3) 3"C -4#300 KCMIL IN EACH TO PAD MOUNT TRANSFORMER. GC /ELECT. CONTRACTOR SHALL COORDINATE SERVICE POLES PER LOCAL UTILITY CODE. IF ALUMINUM CONDUCTORS ARE USED PROVIDE (3) 3"C -4#400 KCMIL IN EACH. EQUIPMENT CABINET IS FURNISHED WITH MAPS LINE. 7 7 THERE SHALL BE U.L. LISTED SERIES RATING BETWEEN CKT. BREAKERS LOCATED AT THE DISTRIBUTION PANEL AND THE DOWNSTREAM 10k A.I.C. RATED CIRCUIT BREAKERS AT PANELS "A", "B", "C", "D"& "H" BASED ON THE MAXIMUM FAULT CURRENT AS DETERMINED AT THE SERVICE ENTRANCE. THE NFPA-70 'SIX SWITCH' MAXIMUM RULE SHALL APPLY AT THE POINT AT WHICH THE SERVICE ENTERS THE BUILDING AS DEFINED BY NFPA-70 (CURRENT EDITION IN FORCE AT THIS SITE). NOTIFY ENGINEER WHERE LOCAL CONDITIONS REQUIRE ALTERNATE LOCATIONS OR SINGLE POINT DISCONNECT. SEE SCOPE OF WORK FOR DETAILS REGARDING OWNER SUPPLIED AND/OR INSTALLED PRODUCTS. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL OTHER ASPECTS OF THE PROJECT IF UTILITY COMPANY PROPOSES A SERVICE DIFFERENT FROM THAT ILLUSTRATED, CONTACT THE CONSTRUCTION ENGINEER FOR A DECISION BEFORE PROCEEDING. COORDINATE AVAILABLE SHORT CIRCUIT CURRENT W/LOCAL UTILITY AND PROVIDE CIRCUIT BREAKERS W/SUFFICIENT INTERRUPTING CAPACITY. COORDINATE CT METERING COMPARTMENT SIZE WITH LOCAL UTILITY COMPANY, THE LOCAL ELECTRICAL INSPECTOR AND THE NATIONAL ELECTRICAL CODE TO MEET ALL REQUIREMENTS BEFORE PURCHASE AND INSTALLATION. NEW METER BY LOCAL UTILITY COMPANY. ALL WIRING SHOWN SHALL BE COPPER TYPE "THHN/THWN" EXCEPT FEEDERS FROM UTILITY TRANSFORMER TO SWITCH BOARD MAY BE ALUMINUM. 1. 2. 3. 4. 5. 5 23 2 2 2 6 1 3 4 2 E2.0 RISER DIAGRAM AND LEGEND #1 #2 #3 #4 #5 #6 SUSPENDED DOWNLIGHT FIXTURE DIRECTIONAL FIXTURE FIXTURE, TRACK MOUNTED TRACK MOUNTED TO DIRECTIONAL FIXTURE, UNDERSIDE OF INTERIOR CANOPY TRACK MOUNTED PENDANT LIGHT FIXTURE PENDANT MOUNTED LIGHT FIXTURE SECURITY STROBE COOLER FIXTURE EXIT SIGN (WALL MOUNTED) EXIT SIGN (CEILING MOUNTED) DOWNLIGHT FIXTURE 2X4 FLUORESCENT FIXTURE 2X4 FLUORESCENT FIXTURE WITH BATTERY PACK 1X4 FLUORESCENT FIXTURE WITH BATTERY PACK 1X4 FLUORESCENT FIXTURE EXTERIOR DECORATIVE WALL FIXTURE EXTERIOR DECORATIVE WALL FIXTURE EXTERIOR WALL FIXTURE FUSIBLE DISCONNECT SWITCH PHOTOCELL RAIN SENSOR NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH FLUORESCENT WALL MOUNT FIXTURE WITH STARTER STARTER EMERGENCY LIGHT TOGGLE SWITCH R SWITCH W/PILOT LIGHT SINGLE POLE, SINGLE THROW TOGGLE RELAY SINGLE POLE, SINGLE THROW CONDUIT RUN, UNDERGROUND SMOKE DETECTOR c CONNECTION TO EQUIPMENT GROUND FAULT DUPLEX OUTLET DEDICATED GROUNDED OUTLET TELEPHONE OUTLET J WALL MOUNTED JUNCTION BOX DUPLEX GROUNDED OUTLET DOUBLE DUPLEX GROUNDED OUTLET SPECIAL PURPOSE OUTLET DUPLEX ISOLATED GROUND OUTLET DEDICATED ISOLATED GROUND CEILING DUPLEX OUTLET GROUND FAULT DUPLEX W/BOTT. HALF SWITCHED HOLD UP EMERGENCY BUTTON SHEET E2.1 FOR PANEL SCHED. ELECTRICAL PANEL. SEE ELECTRICAL MOTOR GROUND FAULT DEDICATED OUTLET DOUBLE DUPLEX ISOLATED GROUND OUTLET CEILING SPECIAL PURPOSE OUTLET DUCT MOUNTED SMOKE DETECTOR J WPG WEATHERPROOF GROUND FAULT SS JUNCTION BOX CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER NIGHT LIGHT MAIN MAIN MAIN MAIN UNDERGROUND FEEDERS INCOMING SERVICE LATERAL TO UTILITY TRANSFORMER 120/208V, 3Ø, 4W CU 22KAIC, CURRENT TRANSFORMER (CT) CAN AND METER SOCKET PER MAIN MAIN SERVING UTILITY CO. SPEC. NOTE: CONFIRM DIMENSIONS WITH SUPPLIER M OUTDOOR NEMA 3R ENCLOSURE TO PANELS "A", "B", "D", "H" & (2) DUAL-LINE EQUIPMENT CABINETS 8 EASTERN REGION T LOW VOLTAGE TRANSFORMER 3P 125AT 2 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 CORPORATE DEVELOPMENT YUM SYSTEM CORPORATE NATIONAL ACCOUNT AGREEMENT IS WITH GEXPRO (formally GE Supply) FOR THE SUPPLY AND DISTRIBUTION OF ELECTRICAL SWITCHGEAR EQUIPMENT FOR COMPANY DEVELOPMENT ONLY. FRANCHISEES SHOULD NOT OBTAIN SWITCHGEAR FROM GEXPRO BECAUSE THE UFPC AGREEMENTS DESIGNED TO PROTECT FRANCHISEES HAVE NOT BEEN COMPLETED (see Franchise Development Option). UNDER THIS AGREEMENT, THE CONTRACTOR IS RESPONSIBLE FOR PURCHASE AND INSTALLATION OF THE SYSTEMS DESCRIBED IN THE PLANS. ALL COMPANY PROJECTS MUST CALL GEXPRO's NATIONAL ACCOUNT DEPARTMENT FOR A PRICE QUOTE AND A BILL OF MATERIAL CONFIRMATION FOR THEIR SPECIFIC PROJECT. SEE THE SWITCHGEAR SECTION IN THE SCOPE OF WORK FOR ADDITIONAL INFORMATION. PRIMARY CONTACT: MIKE URKOSKI PHONE: (630) 718-6529 FAX: (630) 718-6567 EMAIL: mike.urkoski@gexpro.com THE GEXPRO SWITCHGEAR PACKAGE CONSISTS OF SERVICE ENTRANCE, SWITCHGEAR, MAIN PANELS, SUB PANELS, AND LIGHTING CONTACTORS. GEXPRO IS ALSO ABLE TO SUPPLY A FULL LINE OF GEXPRO AND NON-GEXPRO PRODUCTS TO COMPLIMENT THE SWITCHGEAR PACKAGE. BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN MAY NOT MATCH PROTOTYPICAL DESIGN. NOTE: THE SITE-ADAPT CONSULTANT IS RESPONSIBLE FOR DETERMINING IF THE SITE-SPECIFIC SWITCHGEAR PACKAGE FALLS WITHIN AN EASTERN REGION OR A WESTERN REGION JURISDICTION. NATIONAL ACCOUNTS: SWITCHGEAR INSTALL STANDARD PACKAGE. SUPPLY and INSTALL NON-STANDARD COMPONENTS. FRANCHISE DEVELOPMENT YUM SYSTEM FRANCHISE SUPPLY OF ELECTRICAL SWITCHGEAR EQUIPMENT IS FROM ACCUSERV. THE ACCUSERV SWITCHGEAR IS TO BE PURCHASED THROUGH APPROVED YUM SYSTEM DISTRIBUTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF THE SYSTEMS DESCRIBED IN THE PLANS. FRANCHISEES SHOULD CONTACT THEIR APPROVED YUM SYSTEM DISTRIBUTOR FOR A PRICE QUOTE AND A BILL OF MATERIAL CONFIRMATION FOR THEIR SPECIFIC PROJECT. SEE THE SWITCHGEAR SECTION IN THE SCOPE OF WORK FOR ADDITIONAL INFORMATION. PRIMARY CONTACT: BUDDY BOCKWEG PHONE: (877) 707-7378 FAX: (502) 961-0357 EMAIL: buddy@accuserv.com THE ACCUSERV SWITCHGEAR PACKAGE CONSISTS OF SERVICE ENTRANCE, SWITCHGEAR, MAIN PANELS, SUB PANELS, LIGHTING CONTACTORS AND ALL ASSOCIATED PRODUCTS TO COMPLIMENT THE SWITCHGEAR PACKAGE. BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN MAY NOT MATCH PROTOTYPICAL DESIGN. NOTE: THE SITE-ADAPT CONSULTANT IS RESPONSIBLE FOR DETERMINING IF THE SITE-SPECIFIC SWITCHGEAR PACKAGE FALLS WITHIN AN EASTERN REGION OR A WESTERN REGION JURISDICTION. 10 6-25-09 REVISION 10