Loading...
HomeMy WebLinkAbout200708816_500_KT_Y07-E5_0.pdf FS J E5.0 COMMUNICATIONS PLAN S 04 S 08 COMMUNICATIONS PLAN 1/4"=1'-0" A COMMUNICATIONS ROUGH-IN SCHEDULE B S 03 J-BOX SECURITY SYSTEM +24" A.F.F. 2X4 J-BOX W/(1) 1/2" CONDUIT TO ABV. CLG. FOR HOLD-UP BUTTON SIGNAL WIRE S 06 J-BOX SECURITY SYSTEM +48" A.F.F. 2X4 J-BOX W/(1) 1/2" CONDUIT TO ABOVE CEILING FOR SECURITY SYSTEM KEYPAD. S 04 J-BOX SECURITY SYSTEM +84" A.F.F. 2X4 J-BOX W/COVER & (1) 1/2" CONDUIT TO ABOVE CEILING. S 05 J-BOX SECURITY SYSTEM +24" A.F.F. 2X4 J-BOX W/3/4" CONDUIT TO ABOVE CEILING. S 07 J-BOX SECURITY SYSTEM TOP OF JAMB 2X4 J-BOX W/(1) 1/2" CONDUIT TO ABOVE CEILING FOR DOOR CONTACT. TV 02 SECURITY CAMERA +96" A.F.F. MINI-DOME CAMERA MTD. TO BTM. OF MENU BOARD BULKHEAD. 2X4 J-BOX W/(1) 1/2" CONDUIT TO ABOVE CEILING MTD. ON BACK SIDE OF BULKHEAD. T 01 +48" A.F.F. PROVIDE (1) 25 PAIR TELEPHONE CABLE. ONLY (2) LINES TO BE USED. LINE ONE FOR VOICE/FAX. LINE (2) FOR COMPUTER MODEM. T 04 COMPUTER LINE PHONE JACK +42" A.F.F. 2X4 J-BOX W/RJ-11 PHONE JACK AND 1" CONDUIT TO ABOVE CEILING. T 03 VOICE LINE PHONE JACK +42" A.F.F. 2X4 J-BOX W/DOUBLE RJ-11 PHONE JACK & 1" CONDUIT TO ABOVE CEILING. T 02 SECURITY SYSTEM PHONE JACK +106" A.F.F. 2X4 J-BOX ADJACENT TO S-02 W/RJ-31X PHONE JACK. V 01 ALTERNATE PAYMENT ROUTER BOX +90" A.F.F. 4X4 J-BOX W/1/2" CONDUIT TO ABOVE CEILING FOR ETHERNET CABLES (DOUBLE JACK) V 02 CREDIT CARD READER (VSAT) +24" A.F.F. 2X4 J-BOX W/1/2" CONDUIT TO ABOVE CEILING FOR ETHERNET CABLES. TV 01 CCTV MONITOR +102" A.F.F. 2X4 J-BOX W/(1) 1/2" CONDUIT TO ABV. CLG. (BOTTOM OF MONITOR TO BE MOUNTED AT 96" A.F.F.). T 05 POS PHONE JACK +24" A.F.F. 2X4 J-BOX W/1" CONDUIT TO ABOVE CEILING. S 08 "SOUND ALERT" DEVICE CEILING CONNECT TO SECURITY SYSTEM. S 09 SECURITY STROBE LIGHT CEILING CONNECT TO SECURITY SYSTEM. S 10 ALARM SIREN ABV. CEILING CONNECT TO SECURITY SYSTEM S 12 J-BOX SECURITY DVR +42" A.F.F. 2X4 J-BOX FOR SECURITY DVR. M 01 SPEAKER, CEILING MOUNTED CEILING SPEAKER WIRING FROM SPEAKERS IN DINING ROOM TO AMPLIFIER IN OFFICE. FOR EXACT LOCATION OF SPEAKERS, SEE LIGHTING PLAN SHEET SHEET E4.0. HM 08 D/T J-BOX +96" A.F.F. 2X4 J-BOX BELOW CEILING W/(1) 1" CONDUIT TO HM-03 & (1) 1" CONDUIT TO HM-07. SEE DET. 16/E3.1. HM 07 D/T J-BOX +108" A.F.F. 2X4 J-BOX ABV. CEILING W/(1) 2-1/2" CONDUIT TO HM-01 & (1) 1" CONDUIT TO HM-08. SEE DET. 16/E3.1. HM 03 D/T BASE STATION J-BOX +72" A.F.F. 4X4 J-BOX @D/T BASE STATION W/(1) 1" CONDUIT TO HM-08 & HM-04. SEE DET. 16/E3.1. HM 04 D/T COMM SYSTEM J-BOX +18" A.F.F. 4X8 J-BOX W/(1) 1" CONDUIT TO HM-02, (1) 1" CONDUIT TO HM-03, (1) 1" CONDUIT TO PICK-UP WINDOW D/T LOOP, AND (3) 1" CONDUITS TO D/T MENU BOARD. SEE DET. 16/E3.1. P 05 KITCHEN MONITOR J-BOX +80" A.F.F. 2X4 J-BOX W/(1) 3/4" CONDUIT TO P-04 AND (1) 3/4" CONDUIT TO ABOVE CEILING. P 02 KITCHEN MONITOR J-BOX @CLG. 2X4 J-BOX FLUSH @CEILING. FOR M.A.P.S. LINE MONITOR J-BOX S 01 J-BOX SECURITY SYSTEM +48" A,F,F, 4X4 J-BOX AT SECURITY SYSTEM CONTROL PANEL W/(1) 2" CONDUIT TO S-02. HM 01 D/T J-BOX +96" U.O.N. 4X4X4" DEEP (MIN.) J-BOX BLW. CEILING W/(1) 2-1/2" CONDUIT TO HM-02 & HM-07. SEE DET. 16/E3.1 COMMUNICATIONS LEGEND D SUPPLY AND INSTALL OUTLETS AND CONDUIT FOR OWNER SUPPLIED AND INSTALLED CABLE AND LOW VOLTAGE WIRING (U.O.N.) TELEPHONE AND MUSIC SYSTEM WIRING SHALL BE SUPPLIED AND INSTALLED. SEE SCOPE OF WORK SHEETS. SEE SHTS. E3.0 AND E3.1 FOR ELECT. INFO ON POS, SECURITY SYSTEM, CCTV SYSTEM, (OFFICE) COMPUTER, DRIVE-THRU TIMER AND DRIVE-THRU COMMUNICATION SYSTEM. THIS PLAN INCLUDES CONDUITS AND J-BOXES FOR POS, SECURITY SYSTEM, CCTV SYSTEM, (OFFICE) COMPUTER, TELEPHONE SYSTEM, MUSIC SYSTEM, DRIVE-THRU TIMER AND DRIVE-THRU COMMUNICATION SYSTEM. ALL OUTLETS AND BOXES MOUNTED IN THE SERVING COUNTER CABINETRY ARE TO BE 24" AFF. INSTALL JUNCTION BOXES WITH CONDUIT UNDER CABINET TO NEAREST WALL AND TO ABOVE CEILING. COMMUNICATIONS NOTES E DOOR CONTACT (LINKED TO AUDIO /VISUAL ALARM) "SOUND ALERT" DEVICE KEYPAD (MTD AT 48" A.F.F.) ALARM SIREN ABOVE CLG BUMP PAD HOOD FIRE SUPPRESSION SYSTEM PULL STATION A. B. C. D. HOLD-UP BUTTON (MOUNT 2-1/2" BEHIND COUNTER EDGE) MUSIC SYSTEM SPEAKERS SECURITY STROBE J-BOX 2" x 4" J-BOX W/DATA PORTS MOTION DETECTOR DOOR CONTACT SJ FS B KP AS IR 01 IRRIGATION TIMER +80" A.F.F. 4X4 J-BOX W/1" CONDUIT TO IRRIGATION VALVES. P 03 KITCHEN MONITOR J-BOX +84" A.F.F. 2X4X4" DEEP (MIN.) J-BOX W/(1) 3/4" CONDUIT TO ABOVE CEILING. P 01 POS J-BOX +24" A.F.F. 2X4 J-BOX W/3/4" CONDUIT TO ABOVE CEILING P 04 BUMP PAD J-BOX +24" A.F.F. 2X4 J-BOX W/(1) 3/4" CONDUIT TO P-05. S 02 J-BOX SECURITY SYSTEM +106" A.F.F. 4X4 J-BOX ADJACENT TO T-02 W/(1) 2" CONDUIT TO S-01. ELEVATION H 01 UNDER COUNTER HOLD-UP BUTTON COM. # EQUIPMENT ITEM REMARKS TELEPHONE SERVICE BOX PER LOCAL TELEPHONE COMPANY. PROVIDE 24"X24"X3/4" PLYWOOD PANEL AT CLG. PROVIDE PULL STRING IN 2" CONDUIT. S 11 MOTION DETECTOR +78" STUB 1/2" CONDUIT COM. # EQUIPMENT ITEM ELEVATION REMARKS CLOSED CIRCUIT TELEVISION (CCTV) THE STANDARD CCTV SYSTEM WILL CONSIST OF (2) CCTV MONITORS, (1) W/WALL BRACKET AND (3) MINI-DOME CAMERAS MTD. TO BTM OF MENU BOARD BULKHEAD. HM 02 D/T TIMER J-BOX +66" A.F.F. 4X4X4" DEEP (MIN.) J-BOX @D/T TIMER W/(1) 1) 2-1/2" CONDUIT TO HM-01 & (1) 1" CONDUIT TO HM-04. SEE DET. 16/E3.1. M 03 MUSIC SYSTEM J-BOX +60" A.F.F. 4X4 J-BOX W/COVER AND W/1/2" CONDUIT TO ABV. CEILING FOR MUSIC SYSTEM. FOR RECIEVER, AMPLIFIER & SPEAKERS SEE SCOPE OF WORK O 01 O 01 (4) 1" DATA CONDUITS U.G. FROM MENU BOARD/SPEAKER POST TO ABOVE CEILING FOR OCB AND D/T COMM. SYST. SEE DET. 16/E6.0. H 02 WALL MOUNTED HOLD-UP BUTTON +18" A.F.F. 2x4 J-BOX FLUSH MOUNTED IN WALK-IN WALL BY COOLER MANUFACTURER WITH 1/2" CONDUIT TO OUTSIDE OF COOLER NEAR KITCHEN CEILING. SECURITY SYSTEM INSTALLER TO INSTALL HOLD-UP BUTTON FACING DOWN AND RUN WIRING H 02 J 14'-0" 22'-5" 32'-5" 32'-11" CL F.O. STUD P 02 P 02 F.O. STUD J P 05 P 04 S 05 24"A.F.F. 80"A.F.F. B TV 01 S M 01 S M 01 S M 01 S 10 AS M 01 S S 09 MOTION DETECTOR MOUNTED TO JAMB S 11 FACE OF STUD P 01 HM 03 HM 08 H 01 S M 01 J F.O. STUD 2'-1" S 06 J J J J H 01 T 05 P 01 S 05 10'-1" 9'-6" 10'-8" S 05 P 01 T 05 1'-6" 2'-1" 2'-8" 5'-412" CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 ENLARGED PLAN 3 E3.1 H 04 27'-10" TI 01 TIMER FOR TACO BELL LED LIGHTING +48" A.F.F. 2X4 J-BOX W/1" CONDUIT TO ABOVE CEILING 6'-9" P 02 10 10 6-25-09 REVISION 10