Loading...
HomeMy WebLinkAbout200708816_001_KT-Y07-T1_0.pdf LEGAL JURISDICTION: CITY OF CARMEL BUILDING CODE: IBC 2006 W/2008 INDIANA AMENDMENTS, 2006 IMC W/2008 INDIANA AMENDMENTS, 1997 UPC W/1999 INDIANA AMENDMENTS, 2005 NEC W/2005 INDIANA AMENDMENTS, IFC 2006 W/2008 INDIANA AMENDMENTS, 1992 MODEL ENERGY CODE W/1992 INDIANA AMENDMENTS BUILDING AREA: BUILDING 2,842 S.F. (PLUS 425 S.F. WALK-IN COOLER/FREEZER = 3,267 S.F. TOTAL) SEATING: 62 OCCUPANCY: A2 TYPE CONSTRUCTION: TYPE VB -UNSPRINKLED # PHONE LINES: 25 PAIR CABLE IN 2" CONDUIT ELECTRIC SERVICE: 800 AMPS /3 PHASE /120-208 VOLT GAS: 1,539,900 BTUH REFER TO CIVIL DRAWINGS. OWNER KFC OF AMERICA 1900 COLONEL SANDERS LANE LOUISVILLE, KY 40213 OPERATING BRAND: KFC CONSTRUCTION MANAGER JEFF GASPER YUM! BRANDS, INC. 439 HERRINGTON HAVEN LANCASTER, KY 40444 PHONE: 859-792-8598 GEOTECHNICAL ENGINEER PROFESSIONAL SERVICE INDUSTRIES, INC. 5362 WEST 78TH STREET INDIANAPOLIS, IN 46268 CONTACT: ERIC BROWN PHONE: 317-876-7723 LANDSCAPE ARCHITECT GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: RYAN OYSTER PHONE: 330-572-2100 SEWER CLAY TOWNSHIP REGIONAL WASTE DISTRICT 10701 NORTH COLLEGE AVE., SUITE A INDIANAPOLIS, IN 46208 CONTACT: RYAN HARTMAN PHONE: 317-844-9200 WATER CITY OF CARMEL, UTILITIES DEPARTMENT 3450 W. 131ST ST. WESTFIELD, IN 46074 CONTACT: STEVE COOK PHONE: 317-733-2855 GAS VECTREN ENERGY 600 INDUSTRIAL DRIVE FRANKLIN, IN 46143 CONTACT: DAVE CATRON Phone: 317-736-2925 ELECTRIC INDIANAPOLIS POWER AND LIGHT COMPANY 1230 WEST MORRIS STREET INDIANAPOLIS, IN 46221 CONTACT: NORM SCHOPPENHORST PHONE: 317-261-5277 TELEPHONE AT&T 5858 NORTH COLLEGE AVE. INDIANAPOLIS, IN 46220 CONTACT: JIM BLACKMAN PHONE: 317-252-4220 EQUIPMENT NUMBER REFERENCE POINT BLDG. HEIGHT REVISION NUMBER DETAIL SHEET DETAIL NUMBER DIRECTION OF DETAIL XXX 000 EQUIPMENT /FIXTURE NUMBER (M.E.P.) SHEAR WALL TYPE (STRUCTURAL) INTERIOR ELEVATION DESIGNATION BLDG. SECTION SHEET X KEY NOTE EXTERIOR WALL FINISH NUMBER WINDOW NUMBER /DECOR ITEM NUMBER DOOR NUMBER ELEV. SHEET ELEV. LETTER BLDG. SECTION LETTER 8'-4" NAME CEILING HEIGHT ELEVATION NUMBER ROOM NAME SHEET NUMBER GENERAL DRAWING SYMBOLS PROJECT GENERAL NOTES VICINITY MAP LEGAL DESCRIPTION DESIGN CRITERIA PROJECT SUMMARY UTILITY CONTACTS PROJECT DIRECTORY SHEET INDEX REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS X X AX.X X AX.X X AX.X 0'-0" ELEV XX ROOM FINISH NUMBER X AX.X 1 2 3 4 X-000 XX X T1.0 TITLE SHEET CIVIL ENGINEER GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: RYAN OYSTER PHONE: 330-572-2100 TITLE/SITE T1.0 TITLE SHEET CIVIL T-001 TITLE SHEET ALTA SURVEY C-001 GENERAL PLAN C-101 DEMOLITION NOTES C-111 SITE PLAN C-121 GRADING PLAN C-131 SWPP PLAN & DETAILS C-141 UTILITY PLAN C-501 DETAILS C-502 DETAILS C-503 DETAILS C-504 DETAILS L-001 LANDSCAPE SPECIFICATIONS L-101 LANDSCAPE PLAN L-501 LANDSCAPE DETAILS STRUCTURAL S1.0 FOUNDATION PLAN S2.0 WALL FRAMING PLAN S3.0 ROOF FRAMING PLAN S4.0 STRUCTURAL DETAILS (FOUNDATION) S4.1 STRUCTURAL DETAILS (FRAMING)) S4.2 STRUCTURAL DETAILS (ROOF) S4.3 STRUCTURAL DETAILS (TACO BELL TOWER) S4.4 STRUCTURAL DETAILS (TACO BELL TOWER) ARCHITECTURAL A1.0 FLOOR PLAN A1.1 DOOR & WINDOW ELEVATIONS & SCHEDULES A2.0 EQUIPMENT AND SEATING PLAN A2.1 EQUIPMENT SCHEDULE A3.0 ROOF PLAN A4.0 EXTERIOR ELEVATIONS A4.1 EXTERIOR ELEVATIONS A5.0 WALL SECTIONS A5.1 WALL SECTIONS A5.2 WALL SECTIONS A5.3 WALL SECTIONS A5.4 WALL SECTIONS A6.0 CONSTRUCTION DETAILS -ROOF A6.1 CONSTRUCTION DETAILS -DOOR & WINDOW A6.2 CONSTRUCTION DETAILS -WALL A6.3 CONSTRUCTION DETAILS -INTERIOR FINISH A6.4 CONSTRUCTION DETAILS -WALL A7.0 FLOOR FINISH PLAN A7.1 REFLECTED CEILING PLAN A7.2 FINISH SCHEDULE A7.3 YUM SPEAK A8.0 INTERIOR ELEVATIONS -DINING ROOM A8.1 INTERIOR ELEVATIONS, ENLARGED RESTROOMS & OFFICE PLAN A8.2 INTERIOR ELEVATIONS -KITCHEN A8.3 INTERIOR ELEVATIONS -KITCHEN ACCESSIBILITY ADA1.0 ACCESSIBILITY REQUIREMENTS ADA1.1 ACCESSIBILITY REQUIRMENTS MECHANICAL M1.0 MECHANICAL SCHEDULES AND NOTES M2.0 DUCT AND DIFFUSER PLAN M3.0 HOOD DRAWINGS -PLANS AND SECTIONS M3.1 HOOD FIRE SUPPRESSION DETAILS M4.0 MECHANICAL & HOOD DETAILS PLUMBING P1.0 PLUMBING SCHEDULES AND NOTES P2.0 WASTE AND VENT PLAN P3.0 WATER AND GAS PLAN P4.0 PLUMBING ROUGH-IN PLAN P5.0 RISER DIAGRAMS P6.0 PLUMBING DETAILS ELECTRICAL E1.0 SITE ELECTRICAL PLAN E2.0 RISER DIAGRAM AND LEGEND E2.1 PANEL SCHEDULES AND LOAD SUMMARY E3.0 POWER FLOOR PLAN E3.1 ENLARGED POWER PLAN AND DETAILS E3.2 POWER ROOF PLAN E4.0 LIGHTING PLAN & SCHEDULE E5.0 COMMUNICATIONS PLAN E6.0 ELECTRICAL DETAILS SCOPE OF WORK IN BOOK FORMAT SPECIFICATIONS IN BOOK FORMAT SEE STRUCTURAL DRAWINGS ALL WORK SHALL CONFORM TO THE 2006 EDITION OF THE INTERNATIONAL BUILDING CODE WITH 2008 INDIANA AMENDMENTS, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE STATE OF INDIANA. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. A201 LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. DRAWINGS ARE BASED ON A SURVEY, DATED MARCH 27, 2008,PREPARED BY A & H SURVEYING, INC. AND IS INCLUDED IN THESE DOCUMENTS. THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS OF A GEOTECHNICAL INVESTIGATION DATED FEBRUARY 28, 2008 BY PROFESSIONAL SERVICE INDUSTRIES, INC. THE REPORT IS PART OF THESE CONTRACT DOCUMENTS, AND THE CONTRACTOR IS RESPONSIBLE FOR CARRYING OUT ITS RECOMMENDATIONS, THOUGH SOME MAY NOT BE SPECIFICALLY DETAILED ON THE PLANS. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE YUM BRANDS CONSTRUCTION MANAGER, IN WRITING, PRIOR TO INSTALLATION. RETAIN THE PROJECT GEOTECHNICAL ENGINEER TO PROVIDE OBSERVATION AND TESTING SERVICES DURING THE GRADING (INCLUDING UTILITY TRENCHES) AND FOUNDATION PHASE OF CONSTRUCTION AS RECOMMENDED IN THE GEOTECHNICAL REPORT. ALL TESTING AND INSPECTION REPORTS, INCLUDING FINAL SUMMATION LETTER, SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND OWNER. G.C. SHALL CERTIFY PAD ELEVATION PRIOR TO START OF FOUNDATION WORK. SUBMIT PAY FEES AND OBTAIN ALL PERMITS ASSOCIATED WITH THE PROJECT EXCEPT GENERAL BUILDING PERMIT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, HOOD ANSUL, OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC. YUM BRANDS WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY PERMITS. PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME OF CONSTRUCTION. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. GC SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS OTHERWISE NOTED. SEE SCOPE OF WORK FOR EXCEPTIONS. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION. A. B. C. D. E. F. G. H. I. J. K. L. M. CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 REVISIONS HEALTH HAMILTON COUNTY HEALTH DEPARTMENT ONE HAMILTON COUNTY SQUARE, SUITE 30 NOBLESVILLE, IN 46060-2229 CONTACT: LARRY BEARD PHONE: 317-776-8500 ARCHITECT GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: RYAN OYSTER PHONE: 330-572-2100 STRUCTURAL ENGINEER GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: RYAN OYSTER PHONE: 330-572-2100 MECH. /ELEC. ENGINEER GPD GROUP 520 S. MAIN STREET, SUITE 2531 AKRON, OH 44311 CONTACT: RYAN OYSTER PHONE: 330-572-2100 REV DATE DESCRIPTION SHEETS T1.0, C-111, C-121, C-131, C-141, S1.0, S2.0, S4.3, A1.0, A1.1, A2.0, A2.1, A6.3, A6.4, A7.1, A7.2, A7.3, A8.0, A8.1, A8.2, A8.3, M1.0, M2.0, M3.1, P1.0, P3.0, P4.0, P5.0, E2.0, E2.1, E3.0, E4.0 10 06.25.09 CORPORATE REVISIONS 10 06.25.09 REVISION 10 10