Loading...
HomeMy WebLinkAbout4 Detention System pg 4 of 7z 0 rr U 3� c W 5 <c\ Q Q a s qt �Z X CY 0 ZQ z 17D aoc F- w Z z E -w Lu cn UZ w ck (J X :ou a 6 AASHTO M288 CLASS 2 NON —WOVEN GEOTEXTILE DETENTION OUTLET STRUCTURE (SEE DETAIL) '7886.00 885.00 CATCH BASIN d ALL STORM STRUCTURES OUTLETTING DIRECTLY INTO DETENTION STRUCTURE SHALL PROVIDE 24" MIN. SUMP AND DOWNTURNED ELBOW re. 12" HDPE PIPE 00000�001 C O on0oCiaou 0000 000 OOo� 0 �0 000 00. 0 C O r 0 o f 00 0 0000 063 n O� "1 ri Cl Cl� .mil o i� n om O i SECTION 'A —A' AASHTO M288 CLASS 2 NON —WOVEN GEOTEXIILE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING SUITABILITY OF SUBGRADE SOILS* ASSINFAVZIPAVIAM 1 2 —INCH WASHED, CRUSHED, ANGULAR STONE CONNECT TO 6" CHAMBER ENIDCAP CONNECT TO UNDERDRAIN 1 2 —INCH WASHED, CRUSHED, ANGULAR STONE. 12" DEPTH UNDER CHAMBERS STORMTECH SC -740 CHAMBER DETENTION SYSTEM INLET OUTLET DETAIL NOT TO SCALE SC -740 END CAP SC -740 CHAMBER II CLASS 'A'" CONCRETE 6" OF #8 STONE OR #2 STONE 886.00'7 15"95 HDPE PIPE 885.00'7 8"0 PVC PIPE WELL GRADED GRANULAR BACKFILL WHICH CONTAIN AN EVEN DISTRIBUTION OF PARTICLE SIZES WITH NO MORE THAN 12% PASSING THE #200 SIEVE COMPACTED TO A MINIMUM OF 95% OF THE STANDARD PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS IN STORMTECH'S DESIGN MANUAL, INSTALLATION MANUAL, OR WWW.STORMTECH.COM. SLOPE SUBGRADE TO DRAIN TO UNDERDRAIN 6" L WELL GRADED GRANULAR BACKFILL WHICH CONTAIN AN EVEN DISTRIBUTION OF PARTICLE SIZES WITH NO MORE THAN 12% PASSING THE #200 SIEVE COMPACTED TO A MINIMUM OF 95% OF THE STANDARD PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS IN STORMTECH'S DESIGN MANUAL, INSTALLATION MANUAL, OR WWW.STORMTECH.COM. 6" SC-740 END CAP SC -740 CHAMBER MIN. STORMTECH SC -740 CHAMBER SYSTEM TYPICAL CROSS SECTION DETAIL NOT TO SCALE ELEVATION 6" '7 889.00 ORIFICE (TYP.) '7887.10 3.5" ORIFICE INSTALL TRASH SCREEN (SEE DETAIL) '7 885.00 2" ORIFICE ORIFICE (TYP.) 8 "0 PERFORATED PVC PIPE UNDERDRAIN. DRAIN TO DETENTION OUTLET STRUCTURE *SEE STORMTECH'S DESIGN MANUAL FOR STORMTECH PURCHASING INFORMATION CALL 1 -888- 892 -2694 A' 30" MIN. 12" 12" MIN. TYP. 18" MIN. ORIFICE (TYP.) AASHTO M288 CLASS 2 NON —WOVEN GEOTEXIILE 3'_O" SC -740 CHAMBE FLOOR BOX FRAME AND LID W/ S.S. CAP SCREW LID CLOSURE 1 24" N PP PLAN DETENTION OUTLET STRUCTURE NO SCALE f NOTE: 6" CONC. PRECAST OR POURED IN PLACE d W 85.4" INSTALLED CLEANOUT WITH SCREW —IN CAP ORIFICE (TYP.) 3" (TYP. Vd CHAMBER ELEVATIONS ILLUSTRATED ON THE UNDERGROUND DETENTION PLAN ARE MEASURED AT THESE POINTS STORMTECH SC -740 CHAMBER NOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) CHAMBER STORAGE MINIMUM INSTALLED STORAGE WEIGHT ■B I■ l■■■■■■ i\■■■ ■■i...YY■■■■ 0111 ■■\!a... .■■■■■■■■Ii..u■■ W. SWI■..■■■■. ii■■■■■i■I.■■ ..■■.■■.■■.°■■M ■7■..■■■ f--- VARIES ACCEPTS 4" SCH 40 PIPE FOR CLEANOUT OR INSPECTION PORT 51.0" x 30.0" x 85.4" 45.9 CUBIC FEET 74.9 CUBIC FEET 75 LB S. STORMTECH SC -740 CHAMBER SYSTEM INSPECTION PORT DETAIL NOT TO SCALE 3" (TYP. CLASS "C" CONCRETE (WHEN IN ASPHALT) FINISH GRADE NTS MIN. ORIFICE (TYP.) ECM .......0 THE BOTTOM OF SCREEN SHALL BE LEFT OPEN SECTION A -A TRASH SCREEN DETAIL NO. 2 THE TOP AND SIDES SHALL BE CLOSED, CONTRACTOR SHALL PERMANENTLY AFFIX SCREEN TO OUTLET STRUCTURE MESH SIZE 3 OPENINGS PER 1" WIRE DIA. 0.072" 1 FINISH G SUBGRAD tieF CHAMBER EXISTING 36" RCP INV. ELEV. 884.17 EXISTING 36" RCP INV. ELEV. 883.98 DOCKET *193 -03 DP /ADLS EXISTING 30"x42" CMP INV. ELEV. 886.13 CHAMBER DETENTION OUTLET STRUCTURE (SEE DETAIL) 890.05 885.05 FINISH GRADE SUBGRADE CHAMBER CHAMBER STR. NO. 4 8 "0 PERFORATED PVC UNDERDRAIN, CONNECT TO DETENTION OUTLET STRUCTURE (SEE DETAILS) FINISH GRADE INSTALL INSPECTION PORT (SEE DETAIL) \a? UNDERGROUND DETENTION PLAN SCALE: 1" 10' 1/5/03 12/4/03 DATE NOVEMBER 21, 2003 INSTALL STORMTECH SC -740 c L TR CHAMBER ROW PER DETAILS THIS SHEET AND STORMTECH SPECIFICATIONS. (TYP.) DESIGNED REVISIONS DRAWN RH cC? E 0 St c S Q P� TEN FINISH GRADE 885.61 SUBGRADE MISCELLANEOUS REVISIONS PER TECHNICAL ADVISORY COMMITTEE REVIEW ADDED MONUMENT SIGN ON NORTH CORNER OF PROPERTY DETENTION SYSTEM PLAN AND DETAILS 10460 MICHIGAN ROAD CHECKED APPROVED CHAMBER 2 ROWS W/ REQUIRE SPACING 9.00' CHAMBER c C� INST\LL SCTION PORT (SE D TAIL) TEN TEN FINISH GRADE SUBGRADE RH RH BY Transportation Development Consultants 3417 S. WWI 1R 9tfSH RIVE, a 16197 (317) 7d0 SHEET OF TEN TEN APPR C