HomeMy WebLinkAboutA401 Wall Sections*M(A MM aISSIBINSITIMI\ =ice MATCH EXISTING FIBEROUS INSULATION (R30) 5/8" GYPSUM WALL BOARD ISOLATION JOINT W/ 1/2" INSULATION SEALANT 4" CONC. SLAB OVER VAPOR BARRIER AND DRAINAGE FILL 12 2X RAFTER FRAMING (SEE STRUCTURAL DWGS) ASPHALT SHINGLE ROOF WITH 30# FELT ICE /WATER SHIELD 3/4" OSB METAL DRIP EDGE PRE. FIN. METAL GUTTER TO MATCH EXISTING 3/4" EXT. GRADE PLYWOOD SOFFIT W/ VENT TO MATCH EXISTING COMPOSITE TRIM PRE. FIN. METAL DOWNSPOUT TO MATCH EXISTING 2X6 STUDS 16" O.C. FIBEROUS INSULATION W/ VAPOR BARRIER INSIDE 3/4" OSB BOARD AIR INFILITRATION BARRIER 1-1/2" AIR SPACE FACE BRICK BRICK TIES 16 O.C. EACH DIRECTION 2X6 TREATED SILL PLATE WI ANCHOR BOLTS CO 48" O.C. 6" CONCRETE MASONRY UNIT GROUT SOLID BELOW FLASHING CONT. FLASHING W/ WEEP HOLES 24" O.C. GRADE FACE BRICK— ROWLOCK COURSE 2" RIGID INSULATION 12" CONCRETE MASONRY UNIT POURED CONCRETE FOUNDATION Wall Section 1 1 0 ASPHALT SHINGLE ROOF WITH 30# FELT ICE /WATER SHIELD 2X RAFTER FRAMING (SEE STRUCTURAL DWGS) 3/4" OSB METAL DRIP EDGE PRE. FIN. METAL GUTTER TO MATCH EXISTING 3/4" EXT. GRADE PLYWOOD SOFFIT WI VENT TO MATCH EXISTING COMPOSITE TRIM LINTEL ANGLE COMPOSITE TRIM PRE. FIN. METAL DOWNSPOUT TO MATCH EXISTING CAST STONE SILL W/ DRIP EDGE 2X6 STUDS CP 16" O.C. FIBEROUS INSULATION W/ VAPOR BARRIER INSIDE 3/4" OSB BOARD FLASHING AIR INFILITRATION BARRIER 1 -1/2" AIR SPACE FACE BRICK BRICK TIES 1016" O.C. EACH DIRECTION 2X6 TREATED SILL PLATE W/ ANCHOR BOLTS 48" O.C. 6" CONCRETE MASONRY UNIT GROUT SOLID BELOW FLASHING CONT. FLASHING W/ WEEP HOLES 24" O.C. GRADE FACE BRICK— ROWLOCK COURSE 2" RIGID INSULATION 12" CONCRETE MASONRY UNIT POURED CONCRETE FOUNDATION 1 AL Altrig1114111 I *Mk JAI" III I I 0 i 1 ALIGN W/ EXISTING RIDGE AND SOFFIT HEIGHT FIBEROUS INSULATION (R30) 5/8" GYPSUM WALL BOARD WOOD SILL AND TRIM TO MATCH EXISTING ISOLATION JOINT W/ 1/2" INSULATION SEALANT 4" CONC. SLAB OVER VAPOR BARRIER AND DRAINAGE FILL Wall Section 1 1 0 cs z 74) Q a H z O U r J U� Carmel Redevelopment Commission 111 West Main Street Carmel, Indiana 46032 317.571 -2787 (ARTS) V W 0 a C co c co Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish at items required for the proper execution and completion of the work. Revisions: Issue Date 1/21/09 Drawn By D.M.C. Checked By B.D.B. Drawing Title: Wall Sections Certified By: Project Number: 28133