E001 Electrical Symbols & Legend
LIGHTING IDENTITY SYMBOLS ABBREVIATIONS AND TERMS SURFACE MOUNTED 2'x4' FIXTURE 0 PHASE EWC ELECTRIC WATER COOLER OF /CI OWNER FURNISHED /CONTRACTOR INSTALLED T DEGREES FAHRENHEIT EX EXISTING OL OVERLOAD A/C AIR CONDITIONING FCU FAN COIL UNIT OZ OUNCE A AMPERES FLR FLOOR P POLE ACCU AIR COOLED CONDENSING UNIT FPVAV FAN POWERED VAV UNIT PE PNEUMATIC ELECTRIC AF AMPERE FUSE FT FOOT, FEET PH PHASE AFC ABOVE FINISHED COUNTER FURN FURNACE PSI POUNDS PER SQUARE INCH AFF ABOVE FINISHED FLOOR G GROUND PSIA POUNDS PER SQUARE INCH ABSOLUTE AHU AIR HANDLING UNIT GC GENERAL CONTRACTOR PSIG POUNDS PER SQUARE INCH GAUGE AIC AMPERES INTERRUPTING CAPACITY GFI GROUND FAULT INTERRUPTING PTAC PACKAGED TERMINAL AIR CONDITIONER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE HHWP HEATING HOT WATER PUMP RCPT RECEPTACLE ARCH ARCHITECT HO HUB OUTLET REV REVOLUTIONS AVG AVERAGE HOA HAND -OFF- AUTOMATIC RM ROOM B/I BYPASS ISOLATION HORIZ HORIZONTAL RPM REVOLUTIONS PER MINUTE BE BOTTOM ELEVATION HP HORSEPOWER RPS REVOLUTIONS PER SECOND BHP BRAKE HORSEPOWER HR HOUR(S) RTU ROOF TOP UNIT BLDG BUILDING HRTU HEATING ONLY ROOFTOP UNIT SF SQUARE FOOT BSMT BASEMENT Hz HERTZ SPEC SPECIFICATION BtuH BRITISH THERMAL UNIT PER HOUR ID INSIDE DIAMETER SQ SQUARE C CONDUIT IN INCH, INCHES ST SHUNT TRIP CB CIRCUIT BREAKER INT INTERIOR STD STANDARD CCW COUNTERCLOCKWISE INV INVERT SW SWITCH CH CHILLER K KELVIN TBI TO BE INSTALLED CHWP CHILLED WATER PUMP kW KILOWATT TBR TO BE REMOVED CLG CEILING LBS POUNDS TR TO REMAIN COMPR COMPRESSOR LTG LIGHTING TE TOP ELEVATION COND CONDENSER MAX MAXIMUM TEMP TEMPERATURE CONV CONVECTOR MBH THOUSAND Btu PER HOUR TF TRANSFER FAN CT COOLING TOWER MC MECHANICAL CONTRACTOR TRANS TRANSITION CU CONDENSING UNIT MCA MINIMUM CIRCUIT AMPS TYP TYPICAL CUH CABINET UNIT HEATER MCC MOTOR CONTROL CENTER UH UNIT HEATER CUV CLASSROOM UNIT VENTILATOR MFR MANUFACTURER UON UNLESS OTHERWISE NOTED CW CLOCKWISE MIN MINIMUM UV UNIT VENTILATOR CWP CONDENSER WATER PUMP MISC MISCELLANEOUS V VOLTS DC DIRECT CURRENT MTD MOUNTED VAV VARIABLE AIR VOLUME DED DEDICATED CIRCUIT MV MEDIUM VOLTAGE VB VACUUM BREAKER DS DISCONNECT SWITCH NA NOT APPLICABLE VERT VERTICAL DWG DRAWING NEC NATIONAL ELECTRIC CODE VF VENTILATION FAN EA EACH NIC NOT IN CONTRACT VFD VARIABLE FREQUENCY DRIVE EC ELECTRICAL CONTRACTOR NL NON- LINEAR W WIRE, WATT EF EXHAUST FAN NOM NOMINAL WP WEATHERPROOF EFF EFFICIENCY NTS NOT TO SCALE W/ WITH EL ELEVATION OD OUTSIDE DIAMETER, OVERFLOW DRAIN W/0 WITHOUT ETR EXISTING TO REMAIN LIGHTING IDENTITY SYMBOLS HE- SURFACE MOUNTED 2'x4' FIXTURE W CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE [4 xsv O SURFACE MOUNTED 2'x4' EMERGENCY FIXTURE r A PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE off Wr RECESSED MOUNTED 2'x4' FIXTURE IIMIl LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE RATING H F- RECESSED MOUNTED 2'x4' EMERGENCY FIXTURE rill CONTACT NORMALLY CLOSED (NC) "TO" -WITH TIMED OPENING) SURFACE MOUNTED 1'x4' FIXTURE 1 FUSED CUTOUTS, "zzA" INDICATES FUSE RATING I SURFACE MOUNTED 1'x4' EMERGENCY FIXTURE al DISCONNECT SWITCH AIR BREAK WITH FUSE, "zzA" INDICATES FUSED RATING zzA RECESSED MOUNTED 1'x4' FIXTURE i OVERLOAD RELAY REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. RECESSED MOUNTED 1'x4' EMERGENCY FIXTURE usi• 1 O 0 SURFACE MOUNTED FIXTURE 0 SURFACE MOUNTED EMERGENCY FIXTURE 0 RECESSED MOUNTED FIXTURE 0 RECESSED MOUNTED EMERGENCY FIXTURE 0 POLE MOUNTED FIXTURE 0 POLE MOUNTED EMERGENCY FIXTURE MOTOR STARTER SWITCH SUSPENDED FIXTURE _0._ POTHEAD -0— SUSPENDED EMERGENCY FIXTURE a• RESISTOR 1-0 WALL MOUNTED FIXTURE I-0 WALL MOUNTED EMERGENCY FIXTURE 0 WALL MOUNTED FIXTURE I f GENERATOR TiI}ll WALL MOUNTED EMERGENCY FIXTURE 0 POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY (3) i ,wx-MA LUMINAIRE STRIP TYPE FIXTURE (2 FOOT) I—I 3- PHASE, 3 -WIRE DELTA CONNECTION LUMINAIRE STRIP TYPE FIXTURE (3 FOOT) I-1 i r LUMINAIRE STRIP TYPE FIXTURE (4 FOOT) I--I ND I xx -x-x EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS INDICATED ON DWGS (MOUNTING HEIGHTS TO BE DETERMINED BY JOB SPECIFICATION Z &I 12 i A C t FIXTURE DOUBLE OR SINGLE HEAD SPOT LIGHT 04 EMERGENCY BATTERY UNIT WITH LIGHTING HEADS V EMERGENCY BATTERY REMOTE LIGHTING HEADS LIGHT TRACK, LENGTH AS INDICATED ON DWGS WITH NUMBER OF LIGHTS INDICATED ON DWGS AND SCHEDULE IN- GROUND OR FLOOR MOUNTED FIXTURE o-Q SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE 0-0 SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE o-0 SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE TWIN LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE o4::::) ROADWAY LUMINAIRE -COBRA HEAD BOLLARD TYPE SITE LIGHTING FIXTURE ONE -LINE IDENTITY SYMBOLS HE- CAPACITOR W CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE [4 xsv O CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE 1:1 30ff MT PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE off Wr LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE 1 tr 1 LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE RATING H F- CONTACT NORMALLY OPEN (NO) ("TC" -WITH TIMED CLOSING) a CONTACT NORMALLY CLOSED (NC) "TO" -WITH TIMED OPENING) CURRENT TRANSFORMER CABINET I zA FUSED CUTOUTS, "zzA" INDICATES FUSE RATING I DISCONNECT SWITCH UNFUSED I r M DISCONNECT SWITCH AIR BREAK WITH FUSE, "zzA" INDICATES FUSED RATING zzA FUSE, "zzA" INDICATES FUSED RATING --"X.,- OVERLOAD RELAY REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. GROUNDING CONNECTION- SYSTEM AND OR EQUIPMENT JUNCTION BOX O KIRK KEY INTERLOCK SYSTEM -o LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL PHASES REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. MOTOR AND LABEL, "3" DENOTES HORSEPOWER (xx- xx -x -x) O MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH f NETWORK PROTECTOR 0 $w MOTOR STARTER SWITCH PANEL BOARD _0._ POTHEAD -0— STRESS CONE -NAM RESISTOR O SHUNT TRIP 1 T MAGNETIC STARTER WITH NEMA SIZE INDICATED 0 GROUND FAULT CIRCUIT INTERRUPTER, PERSONNEL PROTECTION root KW RATOR GENERATOR TiI}ll TRANSFORMER, DRY TYPE, UNLESS OTHERWISE INDICATED 0 POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY (3) i ,wx-MA CURRENT TRANSFORMER, "3" INDICATES QUANTITY, "400 -5A" INDICATED RATIO Q 3- PHASE, 3 -WIRE DELTA CONNECTION 13 CORNER GROUNDED DELTA i r 3- PHASE, 4 -WIRE WYE CONNECTION (GROUNDED NEUTRAL) ND I xx -x-x ADJUSTABLE FREQUENCY DRIVE 3 REFERENCES DETAIL NUMBER PHASE, PHASE, GROUND BUS DUCT OR BUS WAY 12 i A HOMERUN WIRE WAY Ixruw MYI EFEW TRANSFER SWITCH POWER IDENTITY SYMBOLS p SINGLE CONVENIENCE RECEPTACLE REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL MOUNT DEVICE SECTION LOCATION BEYOND AREA IN DRAWING MODULE EXTENSION Al PLAN DOUBLE DUPLEX CONVENIENCE RECEPTACLE. Di SINGLE CONVENIENCE RECEPTACLE ON EMERGENCY /STANDBY CIRCUIT c DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY /STANDBY CIRCUIT IlIc DOUBLE DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY /STANDBY CIRCUIT REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. SPECIAL RECEPTACLE a CLOCK HANGER OUTLET RECESSED MOUNTED 8' -0" AFF OR 8" BELOW CEILING AS INDICATED LARGE IN DRAWING Al t E -401 k LARGE AT SUBSET MULTI OUTLET ASSEMBLY r gLt MULTI OUTLET ASSEMBLY A l SCALE: NUMERIC SCALE" FLOOR DUPLEX CONVENIENCE RECEPTACLE. g!i SCALE VIEW LOCATION DETAIL LOCATION AT SHEET SUBSET SHEET MATCH LINE INDICATOR: FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH POWER AND VOICE /DATA RECEPTACLES OI; LE REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. JUNCTION BOX 0 MOTOR El PUSH- BUTTON REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. ON /OFF PUSH BUTTON STATION 8 0 A THREE FUNCTION PUSH BUTTON SWITCH (UP /DOWN /STOP) El 0 $w MOTOR STARTER SWITCH TOGGLE DISCONNECT SWITCH HYDROGEN DETECTOR THERMAL MOTOR SWITCH WITH HANDLE GUARD AND PADLOCK CAPABILITY, "P INDICATES PILOT LIGHT TP Di DISCONNECT SWITCH, UNFUSED TYPE Ep DISCONNECT SWITCH, FUSED TYPE j ENCLOSED CIRCUIT BREAKER I MAGNETIC CONTACTOR TAMPER SWITCH, BY DIVISION 15 p MAGNETIC MOTOR STARTER 0 POST INDICATOR VALVE, BY DIVISION 15 EP COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH 0 PHASE, NEUTRAL, GROUND 13 PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND PHASE, PHASE, GROUND PHASE, PHASE, PHASE, GROUND A HOMERUN 4 PHASE, NEUTRAL, GROUND, HOMERUN GROUND CONNECTION FIRE ALARM IDENTITY SYMBOLS REFERENCE REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. SYMBOLS KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. SECTION INDICATOR: SECTION LOCATION BEYOND AREA IN DRAWING MODULE EXTENSION Al PLAN POINT LEADER Di KEYNOTE INDICATORS NUMERICAL CHARACTER 1 RELATES TO ITEM E -301 SECTION LOCATION AT SUBSET SHEET AREA LEADER LINE LEADER DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: Yw REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. LARGE IN DRAWING Al t E -401 k LARGE AT SUBSET SCALE VIEW LOCATION DETAIL LOCATION IN MODULE DRAWING MODULE DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) DRAWING BLOCK TITLE Al N E -501 A l SCALE: NUMERIC SCALE" 1 /a" t' -o 0 4 8 16' GRAPHIC SCALE NORTH ARROW SCALE VIEW LOCATION DETAIL LOCATION AT SHEET SUBSET SHEET MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. FLOOR SEE REFER TO ADDITIONAL SHEET FOR CONTINUATION PLAN OVERLAP BEYOND AREA EXTENSION E -102 MIN SELF CONTAINED SMOKE DETECTOR- SINGLE STATION TYPE REVISION INDICATOR REVISION CLOUD PLAN LIGHTING INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. 'E BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT 0 A "A" FIXTURE TYPE, REFER TO FIXTURE SCHEDULE, "2" CIRCUIT NUMBER, "a" SWITCH IDENTIFICATION FLAME DETECTOR 0 AUTOMATIC HEAT DETECTOR, "R" INDICATES RATE OF RISE a FIRE ALARM IDENTITY SYMBOLS CONTROL RELAY S4 CONTROL RELAY SWITCH (EDIT AS NEEDED FOR 2 -WAY, 3 -WAY, OR a SWITCH LEG ETC. Di HORN AND STROBE 04 HORN UNIT ONLY EA STROBE UNIT ONLY FN SPEAKER AND STROBE Yw MANUAL PULL STATION Li TELEPHONE OUTLET FLOOR TYPE 0 SMOKE DETECTOR ®b DUCT SMOKE DETECTOR WITH TWO AUXILIARY CONTACTS SMC REMOTE STATION FOR DUCT DETECTOR USED AT DUCT WORK OPENING GM CABLE ANTENNA SYSTEM OUTLET (CAN) ©A AREA TYPE SMOKE DETECTOR USED AT DUCT WORK OPENING Ci ELEVATOR RECALL WITH AUXILIARY CONTACTS tsc SELF CONTAINED SMOKE DETECTOR- SINGLE STATION TYPE sk, SMOKE DETECTOR- VISUAL AND AUDIBLE SIGNAL ®k BEAM SMOKE DETECTOR, "R INDICATES RECEIVER 'E BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT 0 CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH BATTERY BACKUP OI FLAME DETECTOR 0 AUTOMATIC HEAT DETECTOR, "R" INDICATES RATE OF RISE <4 AUTOMATIC HEAT DETECTOR, "F" INDICATES FIXED TEMPERATURE 190'F HYDROGEN DETECTOR c MOTOR OPERATED FIRE /SMOKE DUCT DAMPER WATER FLOW SWITCH, BY DIVISION 15 E LOW PRESSURE SWITCH, BY DIVISION 15 I J•■L TAMPER SWITCH, BY DIVISION 15 p EQUIPMENT RACK -FREE STANDING in. POST INDICATOR VALVE, BY DIVISION 15 PIV TERMINAL CABINET WITH 3/4" PLYWOOD BACKING 0 END -OF -LINE RESISTOR 13 PLYWOOD BACKBOARD COMMUNICATION IDENTITY SYMBOLS V DATA OUTLET S4 DATA OUTLET FLOOR TYPE 0 SWITCH (EDIT AS NEEDED FOR 2 -WAY, 3 -WAY, OR a SWITCH LEG ETC. V TELEPHONE /DATA OUTLET SGT TELEPHONE /DATA OUTLET FLOOR TYPE a GLOW SWITCH TOGGLE, GLOWS IN OFF POSITION V TELEPHONE OUTLET Yw TELEPHONE OUTLET -WALL MOUNTED SKp TELEPHONE OUTLET FLOOR TYPE C7 LOW VOLTAGE SWITCH SLM CALL IN SWITCH SMC MOMENTARY CONTACT SWITCH SP CABLE ANTENNA SYSTEM OUTLET (CAN) 4 MASTER ANTENNA SYSTEM OUTLET (MAW) MICROPHONE OUTLET -FLOOR MOUNTED Q MICROPHONE OUTLET -WALL MOUNTED SPEAKER- CEILING MOUNTED 9 SPEAKER -WALL MOUNTED 7 SPEAKER HORN 41 SPEAKER BI- DIRECTIONAL PAGING -WALL MOUNTED OI SPEAKER BI- DIRECTIONAL PAGING CEILING MOUNTED LL INTERCOM UNIT -FLUSH MOUNTED SECURITY DOOR CONTACTS M. MASTER INTERCOM AND DIRECTORY UNIT SECURITY EXIT PUSH BUTTON VOLUME CONTROL u EQUIPMENT CABINET J•■L EQUIPMENT RACK -WALL MOUNTED EQUIPMENT RACK -FREE STANDING in. TERMINAL CABINET WITH 3/4" PLYWOOD BACKING 0 PLYWOOD BACKBOARD SWITCH IDENTITY SYMBOLS S SINGLE POLE SWITCH S4 SWITCH (EDIT AS NEEDED FOR 2 -WAY, 3 -WAY, a SWITCH Sp SWITCH (EDIT AS NEEDED FOR 2 -WAY, 3 -WAY, OR a SWITCH LEG ETC. S? CIRCUIT BREAKER SWITCH SGT SINGLE POLE /DOUBLE THROW SWITCH SG GLOW SWITCH TOGGLE, GLOWS IN OFF POSITION SH HORIZONTALLY MOUNTED -WITH ON POSITION TO THE LEFT SK KEY OPERATED SWITCH SKp KEY OPERATED SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON SLy LOW VOLTAGE SWITCH SLM LOW VOLTAGE MASTER SWITCH SMC MOMENTARY CONTACT SWITCH SP SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON ST TIMER SWITCH Sup WEATHERPROOF SINGLE POLE SWITCH M DIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE INDICATED. "LV" LOW VOLTAGE "FL" FLUORESCENT CI SECURITY DOOR ALARM MAGNETIC LOCK 4 OOVERRIDE CCUPANCY SWITCH SENSOR, WALL MOUNTED WITH OFF -AUTO TPR OCCUPANCY SENSOR, CEILING MOUNTED, "P INDICATES MULTIPLE SWITCHES WIRED IN PARALLEL htg INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) IAM SECURITY CONTROL PANEL SECURITY IDENTITY SYMBOLS MCI CCTV CAMERA "WP" INDICATES WEATHER -PROOF EXTERIOR CAMERA CCTV COAXIAL CABLE OUTLET AND POWER OUTLET CCTV MONITOR OUTLET CID DOORBELL e0/ DOOR BUZZER a DOOR CHIME LKJ ELECTRIC DOOR OPENER 1 FIRE ALARM ANNUNCIATOR PANEL, 2 LINES OF 4' CHARACTERS LCD DISPLAY DRY TYPE TRANSFORMER ELECTRIC DOOR STRIKE IIE FIRE ALARM CONTROL PANEL GENERATOR INTERCOM UNIT FLUSH MOUNT VOICE EVACUATION PANEL METER AND SOCKET MASTER INTERCOM AND DIRECTORY UNIT Ell 'BATTI MOTION DETECTOR M AIR SAMPLING CONTROL /DETECTOR PANEL WITH ASSOCIATED AIR SAMPLING PIPING NETWORK SECURITY DOOR ALARM MAGNETIC LOCK n TRANSPONDER TPR SECURITY CARD READER. "WP" INDICATES WEATHER -PROOF htg INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) IAM SECURITY CONTROL PANEL LL INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES CONTACT CLOSURE) SECURITY DOOR CONTACTS M. 0 SECURITY EXIT PUSH BUTTON SECURITY KEYPAD CI FIRE ALARM COMM IDENTITY SYMBOLS LJ FIRE ALARM MASTER BOX V FIRE FIGHTER'S PHONE CODE TRANSMITTER ij LIGHTING OR POWER PANEL ON NORMAL /GENERATOR FEEDER DRILL KEY SWITCH CZ MOTOR CONTROL CENTER (MCC) LKJ KEY REPOSITORY (KNOX BOX) olu o FIRE ALARM ANNUNCIATOR PANEL, 2 LINES OF 4' CHARACTERS LCD DISPLAY DRY TYPE TRANSFORMER TRANSFORMER -PAD MOUNT CURRENT TRANSFORMER CABINET FIRE ALARM CONTROL PANEL GENERATOR IEVACI VOICE EVACUATION PANEL METER AND SOCKET FIRE ALARM TERMINAL CABINET Ers 'BATTI BATTERY PACK AND CHARGER AIR SAMPLING CONTROL /DETECTOR PANEL WITH ASSOCIATED AIR SAMPLING PIPING NETWORK TRANSPONDER TPR INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) IAM INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES CONTACT CLOSURE) DISTRIBUTION IDENTITY SYMBOLS O LIGHTING OR POWER PANEL, RECESSED LIGHTING OR POWER PANEL, SURFACE DISTRIBUTION PANEL SHEET KEYNOTES: LIGHTING OR POWER PANEL ON NORMAL /GENERATOR FEEDER DISTRIBUTION PANEL ON NORMAL /GENERATOR FEEDER MOTOR CONTROL CENTER (MCC) olu o DRY TYPE TRANSFORMER TRANSFORMER -PAD MOUNT CURRENT TRANSFORMER CABINET 4 GENERATOR METER a METER AND SOCKET TRANSFER SWITCH SWITCHBOARD METER IDENTITY SYMBOLS O CUSTOMER METER 0 D DEMAND METER (UTILITY) t: WATTHOUR METER (UTILITY) SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. NOTATION DESIGNATORS GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL ELECTRICAL NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. GENERAL ELECTRICAL NOTES A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL /MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. D. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. F. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. G. FEEDERS FROM PANEL BOARDS BACK TO MAIN SWITCHBOARD, BETWEEN AUTO TRANSFER SWITCHES AND THEIR SOURCES /LOADS, BETWEEN DRY TRANSFORMERS AND THEIR SOURCES /LOADS. ARE NOT INDICATED ON THE FLOOR PLAN DRAWINGS. FEEDERS ARE PART OF THE WORK, AND SHALL BE SIZED AS INDICATED ON THE ONE LINE DIAGRAM. H. CABLE TRAY IS SHOWN ON THE PLANS. IF PORTIONS OF CABLE TRAY CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE OR OTHER EQUIPMENT, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY TO AVOID CONFLICTS IN THESE LOCATIONS. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. J. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK SEALS. WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED PER SECTION 260523 NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND TERMINALS. K. L. G -000 A -000 F -000 P -000 M -000 E -000 T -000 SUBSET DESIGNATORS GENERAL ARCHITECTURAL FIRE PROTECTION PLUMBING MECHANICAL ELECTRICAL TELECOMMUNICATION SHEET TYPE DESIGNATORS E -000 E -100 E -200 E -300 E -400 E -500 E -600 E -700 E -800 E -900 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) PLANS (DEMOLITION, SITE, FOUNDATION) PLANS (LIGHTING) PLANS (POWER) LARGE SCALE VIEWS (PLANS, SECTIONS) DETAILS SCHEDULES SHORT SPECIFICATIONS DIAGRAMS (CONTROLS, RISERS, ONE- LINES) 3D REPRESENTATIONS (ISOMETRICS) Carmel Redevelopment Commission 111 West Main Street Carmel, Indiana 46032 317.571 -2787 (ARTS) co C a) E Rf U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Revisions: Issue Date 01/20/09 Drawn By KIA Checked By BKS Drawing Title: ELECTRICAL SYMBOLS AND LEGEND SHEET e 9'iG lIaiII1 7 "1 Certified Br 0 E1d0 /oct L'Acqubl Project Number: 08109