Loading...
HomeMy WebLinkAboutE201 Electrical Power & Systems PlansSCALE: 1/8" 1' -0" 0 4' 8' 16' C7� t7 ELECTRICAL EXISTING /DEMOLITION PLAN POWER /SYSTEMS; SPECIAL REC. WITH STARTER TO REMAIN. COORDINATE WITH ARCH. KITCHEN EQUIPMENT INFORMATION WAS NOT PROVIDED AT THE TIME OF THIS DESIGN. VERIFY LOAD SIZE AND ROUGH -IN HEIGHT WITH F.S.E.C. AND ARCHITECT PRIOR TO CONSTRUCTION. KLLPP -2, 5 0 PIV -1 :F21 C LP -1, 1 KLP, -2, KLP-Z 22 2 (Dc L GFf LP 1 LP -1, 36 LP -1, 38 SCALE: 1/8" 1' -0" 46 KLP -2 KLP -2 34,36 38,40 AHU -3 AHU -4 GF -3 GF -4 LP -1, 1 L LP -1, 1 P -1, 11 KLP -2 AHU -3 26,28 GF -2 AHU KLP -2 GF -1 30,32 LP -1 KLP -2 tb GFI LP -1, 11 WP CU -2 4 CU -3 4 CU -1 Q CU -4 KLP -2 LP -1 KLP -2 LP -1 29,31 12,14 25,27 16,18 0 4' 8' 16' FA Q LP -1 9 LP -1, 9 9 G Fl GFI 22 GFI GFI KLP -2, 3 EF -3 ,5 GFI LP 1, 9 4) LP 1,8 GFI ,3 GFI LP-1, 8 14 LP -1, 8 CFI LP -1 8 cp LP -1, 7 LP -1, 7 e O ELECTRICAL FIRST FLOOR POWER /SYSTEMS PLAN (TNY) KLP -2, 16 LP -1, 8 GA LP -1,:10 KLP -2, 21,23 GENERAL NOTES A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL /MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. D. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. F. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. G. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. H. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK SEALS. J. WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND TERMINALS. K. PROVIDE COMPLETE SECURITY SYSTEM FOR BURGLAR PROTECTION. PROVIDE DOOR CONTACTS AT ALL EXTERIOR DOORS, MOTION DETECTORS AS INDICATED, CONNECT COMPLETE TO DIALER FRO REMOTE NOTIFICATION. SHEET KEYNOTES 1. ALL DASHED LINES INDICATE DEVICES TO BE REMOVED. 2. ALL LIGHT SOLID LINES INDICATE DEVICES TO REMAIN. 3. RELOCATE UTILITY METER. 4. EXISTING CONDENSING UNIT TO BE REMOVED AND TURNED OVER TO OWNER. 5. EXISTING ELECTRICAL PANEL TO BE RELOCATED AS SHOWN. RECONNECT ALL EXISTING CIRCUITS. 6. PROVIDE NEW UL OUTDOOR RATED WIRE -WAY AND MOUNT ON OPPOSITE SIDE OF WALL FROM NEW PANELS AS SHOWN. 7. PROVIDE CIRCUIT FOR FUTURE POOL TABLE LIGHTING. COORDINATE EXACT LOCATION WITH ARCH. AND OWNER. 8. PROVIDE HUNTER FAN 23860 LOW PROFILE ANTIQUE CEILING FAN. COORDINATE REQUIRED COLOR WITH ARCH. PRIOR TO PLACING ORDER. 9. PROVIDE QUIET FAN CONTROL WITH LED LOCATOR AND SPEED DISPLAY LEVITON ACF01 -1 L OR APPROVED EQUIVALENT. 10. PROVIDE JUNCTION BOX FOR RECONNECTING ALL EXISTING CIRCUITS TO RELOCATED PANELBOARD. 11. PROVIDE DISCONNECT AND CIRCUITS AS SHOWN FOR WALK -IN COOLER COMPRESSOR. COORDINATE EXACT LOCATION WITH MECH. CONSULTANT. 12. PROVIDE CIRCUIT FOR WALK -IN COOLER LIGHTING. COORDINATE EXACT LOCATION AND WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER. 13. PROVIDE CIRCUIT FOR PIPE MOUNTED AIR COMPRESSOR IN WALK -IN COOLER. COORDINATE EXACT LOCATION AND WIRING REQUIREMENTS WITH MECH. CONSULTANT. 14. LOCATE PIV OUTSIDE WALK -IN COOLER. COORDINATE EXACT LOCATION AND WIRING REQUIREMENTS WITH MECH. CONSULTANT. 15. PROVIDE 50 POINT ANALOG /ADDRESSABLE FIRE ALARM CONTROL SYSTEM FARENHYT IFP -50 OR APPROVED EQUIVALENT. 16. INSTALL SECURITY TOUCHPAD STATION ADJACENT DOOR SECURITY PANEL SHALL BE INSTALLED IN MECHANICAL ROOM. cn rgu) w z C z z oi.1 O Carmel Redevelopment Commission 111 West Main Street Carmel, Indiana 46032 317.571 -2787 (ARTS) C s c C G) E R3 U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Revisions: Issue Date 01/20/09 Drawn By KIA Checked By BKS Drawing Title: ELECTRICAL POWER AND SYSTEMS PLANS Certified Br 11 1111 PE 1970'01 STATE OF L'Acquis Project Number: 08109