HomeMy WebLinkAboutE201 Electrical Power & Systems PlansSCALE: 1/8" 1' -0"
0 4' 8'
16'
C7� t7
ELECTRICAL EXISTING /DEMOLITION PLAN POWER /SYSTEMS;
SPECIAL REC.
WITH STARTER
TO REMAIN.
COORDINATE
WITH ARCH.
KITCHEN EQUIPMENT INFORMATION WAS NOT PROVIDED AT THE
TIME OF THIS DESIGN. VERIFY LOAD SIZE AND ROUGH -IN HEIGHT
WITH F.S.E.C. AND ARCHITECT PRIOR TO CONSTRUCTION.
KLLPP -2, 5
0
PIV
-1 :F21 C LP -1, 1
KLP, -2,
KLP-Z 22
2 (Dc L
GFf
LP 1
LP -1, 36
LP -1, 38
SCALE: 1/8" 1' -0"
46
KLP -2 KLP -2
34,36 38,40
AHU -3 AHU -4
GF -3 GF -4
LP -1, 1
L
LP -1, 1 P -1, 11
KLP -2
AHU -3 26,28
GF -2 AHU
KLP -2 GF -1
30,32 LP -1 KLP -2
tb GFI
LP -1, 11 WP
CU -2 4 CU -3 4 CU -1 Q CU -4
KLP -2 LP -1 KLP -2 LP -1
29,31 12,14 25,27 16,18
0 4' 8' 16'
FA Q
LP -1 9
LP -1, 9 9
G Fl GFI
22 GFI GFI KLP -2, 3 EF -3
,5 GFI LP 1, 9
4) LP 1,8
GFI ,3
GFI
LP-1, 8
14
LP -1, 8
CFI
LP -1 8 cp
LP -1, 7
LP -1, 7 e
O
ELECTRICAL FIRST FLOOR POWER /SYSTEMS PLAN (TNY)
KLP -2, 16
LP -1, 8
GA
LP -1,:10
KLP -2, 21,23
GENERAL NOTES
A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE
APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED.
B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL
ELECTRICAL CODE LATEST EDITION ADOPTED BY INDIANA, THE
INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL /MUNICIPAL CODES,
AND THE AUTHORITY HAVING JURISDICTION.
C. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR
VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT
LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH.
D. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE
CONDUIT SEALING MATERIAL.
E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS.
F. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN
ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS
SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS
SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND
MANUFACTURER'S WRITTEN RECOMMENDATIONS.
G. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN
ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME
RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT
GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS,
AND A GROUNDING CONDUCTOR.
H. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED
NEUTRAL BACK TO THE PANEL.
CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL
USE LINK SEALS.
J. WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE
INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED NOT
EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES
FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND
TERMINALS.
K. PROVIDE COMPLETE SECURITY SYSTEM FOR BURGLAR PROTECTION.
PROVIDE DOOR CONTACTS AT ALL EXTERIOR DOORS, MOTION
DETECTORS AS INDICATED, CONNECT COMPLETE TO DIALER FRO
REMOTE NOTIFICATION.
SHEET KEYNOTES
1. ALL DASHED LINES INDICATE DEVICES TO BE REMOVED.
2. ALL LIGHT SOLID LINES INDICATE DEVICES TO REMAIN.
3. RELOCATE UTILITY METER.
4. EXISTING CONDENSING UNIT TO BE REMOVED AND TURNED OVER TO
OWNER.
5. EXISTING ELECTRICAL PANEL TO BE RELOCATED AS SHOWN.
RECONNECT ALL EXISTING CIRCUITS.
6. PROVIDE NEW UL OUTDOOR RATED WIRE -WAY AND MOUNT ON
OPPOSITE SIDE OF WALL FROM NEW PANELS AS SHOWN.
7. PROVIDE CIRCUIT FOR FUTURE POOL TABLE LIGHTING. COORDINATE
EXACT LOCATION WITH ARCH. AND OWNER.
8. PROVIDE HUNTER FAN 23860 LOW PROFILE ANTIQUE CEILING FAN.
COORDINATE REQUIRED COLOR WITH ARCH. PRIOR TO PLACING ORDER.
9. PROVIDE QUIET FAN CONTROL WITH LED LOCATOR AND SPEED DISPLAY
LEVITON ACF01 -1 L OR APPROVED EQUIVALENT.
10. PROVIDE JUNCTION BOX FOR RECONNECTING ALL EXISTING CIRCUITS
TO RELOCATED PANELBOARD.
11. PROVIDE DISCONNECT AND CIRCUITS AS SHOWN FOR WALK -IN COOLER
COMPRESSOR. COORDINATE EXACT LOCATION WITH MECH. CONSULTANT.
12. PROVIDE CIRCUIT FOR WALK -IN COOLER LIGHTING. COORDINATE EXACT
LOCATION AND WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER.
13. PROVIDE CIRCUIT FOR PIPE MOUNTED AIR COMPRESSOR IN WALK -IN
COOLER. COORDINATE EXACT LOCATION AND WIRING REQUIREMENTS
WITH MECH. CONSULTANT.
14. LOCATE PIV OUTSIDE WALK -IN COOLER. COORDINATE EXACT LOCATION
AND WIRING REQUIREMENTS WITH MECH. CONSULTANT.
15. PROVIDE 50 POINT ANALOG /ADDRESSABLE FIRE ALARM CONTROL
SYSTEM FARENHYT IFP -50 OR APPROVED EQUIVALENT.
16. INSTALL SECURITY TOUCHPAD STATION ADJACENT DOOR SECURITY
PANEL SHALL BE INSTALLED IN MECHANICAL ROOM.
cn rgu)
w
z
C
z
z
oi.1 O
Carmel
Redevelopment Commission
111 West Main Street
Carmel, Indiana 46032
317.571 -2787 (ARTS)
C
s c
C
G)
E
R3
U
Scope Drawings:
These drawings indicate the general scope of the project
in terms of architectural design concept, the dimensions of
the building, the major architectural elements and the type
of structural, mechanical and electrical systems.
The drawings do not necessarily indicate or describe all
work required for full performance and completion of the
requirements of the Contract.
On the basis of the general scope indicated or described,
the trade contractors shall furnish all items required for the
proper execution and completion of the work.
Revisions:
Issue Date
01/20/09
Drawn By
KIA
Checked By
BKS
Drawing Title:
ELECTRICAL
POWER AND
SYSTEMS
PLANS
Certified Br
11 1111
PE 1970'01
STATE OF
L'Acquis Project Number:
08109