HomeMy WebLinkAboutE202 Electrical Lighting PlansGENERAL NOTES A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL /MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. D. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. F. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. I. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. J. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. K. L. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK SEALS. WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND TERMINALS. 1 SHEET KEYNOTES 1. CONTROL WITH PHOTOCELL AND CONTACTOR. TYPICAL FOR ALL EXTERIOR LIGHTING. 2. PROVIDE 4" OPEN DOWNLIGHT TYPE 'A' COOPER LIGHTING C60 -18 —E- 6050 —W OR APPROVED EQUIVALENT. INCLUDE EMERGENCY BATTERY MODULE WHERE SHOWN. 3. PROVIDE 6" OPEN DOWNLIGHT TYPE 'E2' COOPER LIGHTING C60- 18 —E —EM- 6050 —W WITH EMERGENCY BATTERY MODULE AND REMOTE TEST SWITCH OR APPROVED EQUIVALENT. 4. PROVIDE WALL MOUNTED LIGHTING TYPE 'D' COOPER LIGHTING MH— WP- 70- 120 —PC OR APPROVED EQUIVALENT WITH REMOTE EMERGENCY BATTERY PACK AT ALL EXIT DOORS. 5. PROVIDE PENDENT TYPE 'F' COOPER LIGHTING 8T— EIVM -2 -32- 120 —EB81 OR APPROVED EQUIVALENT. INCLUDE EMERGENCY BATTERY PACK FOR THE SECOND FIXTURE IN MECH. ROOM TYPE 'F1'. MOUNT SUSPENDED FROM CEILING. COORDINATE MOUNTING LOCATION WITH MECHANICAL CONSULTANT. 6. PROVIDE EMERGENCY HEAD TYPE 'X2' COOPER LIGHTING LM1 SERIES OR APPROVED EQUIVALENT. 7. PROVIDE EXIT SIGN AND EMERGENCY LIGHT COMBO TYPE 'X' COOPER LIGHTING CCX1- 7- 1 —R —WH- 120 —DH OR APPROVED EQUIVALENT. 8. REMOVE AND REINSTALL FIXTURES IN THIS AREA TO ALLOW FOR CEILING WORK. 9. SAME AS TYPE 'E2' WITH 120V DIMMING BALLAST. 10. SAME AS TYPE 'A' WITH 120V DIMMING BALLAST. PROVIDE RECESSED TYPE 'F3' COOPER LIGHTING WTS- 2 -32 —W- 120 —EB8 COMPLETE WITH LENS OR APPROVED EQUIVALENT. INCLUDE EMERGENCY BATTERY PACK FOR THE SECOND FIXTURE TYPE 'F2'. 12. PROVIDE LUTRON NOVA —T SERIES DIMMERS OR APPROVED EQUIVALENT. 13. PROVIDE RECESSED TYPE 'F4' COOPER LIGHTING 8T— SN -1 -32- 120— ER -8 -1 COMPLETE WITH RED US FLAG ROSCO SLEEVE 4' T8 AND END CAP OR APPROVED EQUIVALENT. MOUNT IN THE INSIDE ARCHITECTURAL COVE. REFER TO ARCH. DRAWING FROM EXACT MOUNTING LOCATION. 14. PROVIDE RECESSED TYPE 'F4' COOPER LIGHTING 8T— SN -1 -32- 120— ER -8 -1 COMPLETE WITH WHITE US FLAG ROSCO SLEEVE 4' T8 AND END CAP OR APPROVED EQUIVALENT. MOUNT IN THE INSIDE ARCHITECTURAL COVE. REFER TO ARCH. DRAWING FROM EXACT MOUNTING LOCATION. PROVIDE RECESSED TYPE 'F4' COOPER LIGHTING 8T— SN -1 -32- 120— ER -8 -1 COMPLETE WITH BLUE US FLAG ROSCO SLEEVE 4' T8 AND END CAP OR APPROVED EQUIVALENT. MOUNT IN THE INSIDE ARCHITECTURAL COVE. REFER TO ARCH. DRAWING FROM FXACT MOUNTING I ()CATION EXISTING SIGNAGE LIGHTING TO REMAIN SCALE: 1/8" 1' -0" 0 0 b U (I) EXISTING SIGNAGE LIGHTING TO REMAIN ELECTRICAL LIGHTING EXISTING /DEMOLITION PLAN *AV SPECIAL REC. WITH STARTER TO REMAIN. 5 D EXISTING SIGNAGE LIGHTING TO REMAIN SCALE: 1/8" 1' -0" 4 ►,4 A I. 0 4' b b 8' 16' f OA 2 15 h F4 2 08 n 4 n ELECTRICAL LIGHTING FIRST FLOOR PLAN EXISTING SIGNAGE LIGHTING TO REMAIN Cr) r4 CD/ w z z V z E a 1 O O Q m 111 West Main Street Carmel, Indiana 46032 317.571 -2787 (ARTS) co co C C tQ 0 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Revisions: Issue Date 01/20/09 Drawn By KIA Checked By BKS Drawing Tuts: ELECTRICAL LIGHTING PLANS Certified By ‘,01,11 (tw Sib?. s 197 0197 a Drawing Number: 202 L'Acquis Project Number: 08109