HomeMy WebLinkAboutE500 Electrical Detail SheetSCALE: NONE
NOTES:
3/4" DIA. X 10' LONG
COPPER CLAD STEEL
GROUND ROD
J
FINISHED FLOOR
EXOTHERMICALLY
WELD CABLE TO
GROUND RODS
CONC. BASE WITH 1" CHAMFER:
PROVIDE VERY HIGH QUALITY
SMOOTH FINISH
#6 AWG GROUND WIRE
FINISH GRADE
GROUND ROD
8 #8 VERT. BARS W/
#3 TIES 16" O.C.
SCALE: NONE
"FS" BOX WITH STAINLESS
STEEL COVER PLATE AS REQ'D.
THREADLESS
CONNECTOR
SCALE: NONE
COUPLING
SCALE: NONE
7-KITCHEN
HOOD
10 -0"
POLE
BASE
COVER
ori)
�(OL�
014
0
24" DIA.
PANEL
3/0 COPPER CABLE
HANDHOLE
SERVICE GROUNDING ELECTRODE
ARRANGEMENT DETAIL
MOUNTING BOLT LAYOUT
PER MFGR. TEMPLATE
s GROUT BASE
THREADLESS
CONNECTOR
KITCHEN WATERPROOF
('j"\ PEDESTAL RECEPTACLE
3/0 COPPER CABLE
POLE BASE DETAIL 30" AFG
SHUNT -TRIP DEVICE
LOCATED IN PANEL
Oi CONTACT CLOSURE (FUSIBLE LINK) ACTIVATED BY HEAT OR FIRE. PROVIDED WITH HOOD.
120V. TO SERVE FIRE PROTECTION SYSTEM IN HOOD.
O3 3P. CIRCUIT BREAKER FOR NP. EQUIP. UNDER THE HOOD.
KITCHEN HOOD SHUNT
TRIP WIRING DIAGRAM
NOTES:
CONTROL STATION
(BY OTHER DIVISION)
GAS VALVE SHUT OFF
WIRING DIAGRAM
CONTROL CONDUIT AND
WIRING TO GAS VALVE RELAY
RELAY PANEL BY DIV. 26
NOTES:
SCALE: NONE
TO SOLENOID VALVE
GAS VALVE CONTROL
STATION FURNISHED
OTHER DIVISION. INSTALLED
AND WIRED BY DIV. 26
GAS VALVE SHUTOFF
SYSTEM DETAIL
SCALE: NONE
TO 240/120V
PANEL PER
240V, 30 FREEZER POWER PLANS
FEED PER EQUIPMENT CABLE
AND CONDUIT SCHEDULE
240V, 3P FUSED
DISCONNECT SWITCH
(BY FREEZER MFR.)
CONDUIT AND WIRING
(BY DIV. 26)
O
000
4
CONTROL
id.)4
I r
SCALE: NONE
TO 240/120V
PANEL PER PLANS
240V, 30 COOLER POWER
FEED PER EQUIPMENT CABLE
AND CONDUIT SCHEDULE
240V, 3P FUSED
DISCONNECT SWITCH
(BY COOLER MFR.)
SCALE: NONE
RELAY PANEL
(BY OTHER DIVISION)
120V.
OPEN SFRJT
EVAPORATOR EQUIPMENT (THERMOSTAT,
SOLENOID VALVE, DRAIN HEATER AND
AND TERMINAL BLOCK BY FEEDER MFR).
WIRING.
4#1 0, #1 OG., 3/4 "C.
CONDUIT AND WIRING
(BY DIV. 26)
GAS VALVE RELAY
PANEL FURNISHED
OTHER DIVISION. INSTALLED
AND WIRED BY DIV. 26
r EVAPORATOR EQUIPMENT (THERMOSTAT,
SOLENOID VALVE, DRAIN HEATER AND
AND TERMINAL BLOCK BY FEEDER MFR).
WIRING.
1. ALL EQUIPMENT SHOWN DARK IS TO BE PROVIDED AND INSTALLED.
2. ALL EQUIPMENT SHOWN SHADED IS BY FREEZER MANUFACTURER.
3. SHOULD THE FREEZER EQUIPMENT CONTRACTOR PROVIDE A FREEZER UNIT
MANUFACTURER THAT REQUIRES ADDITIONAL CONDUIT AND WIRING THAN SHOWN, THE
COST FOR SUCH WORK SHALL BE THE RESPONSIBILITY OF THE FREEZER EQUIPMENT
CONTRACTOR.
FREEZER WIRING DIAGRAM
TO 240/120V
PANEL PER PLANS
2#10, #10G., 3/4 "C.
JUNCTION R S)
BOX BY EVAPORATOR COOLER MFR
THERMOSTAT AND SOLENOID
4 #10, #10G., 3/4 "C. VALVE BY COOLER MFR.
1. ALL EQUIPMENT SHOWN DARK IS TO BE PROVIDED BY DIVISION 26.
2. ALL EQUIPMENT SHOWN SHADED IS BY OTHER DIVISION.
3. SHOULD THE COOLER EQUIPMENT CONTRACTOR PROVIDE A COOLER UNIT MANUFACTURER
THAT REQUIRES ADDITIONAL CONDUIT AND WIRING THAN SHOWN, THE COST FOR SUCH
WORK SHALL BE THE RESPONSIBILITY OF THE COOLER EQUIPMENT CONTRACTOR.
COOLER WIRING DIAGRAM
z
J
cn cn
ow
z o
J
p0
Cn
un
F-
z
z
l' z
o
111 West Main Street
Carmel, Indiana 46032
317.571 -2787 (ARTS)
C
co
C
E
Scope Drawings:
These drawings indicate the general scope of the project
in terms of architectural design concept, the dimensions of
the building, the major architectural elements and the type
of structural, mechanical and electrical systems.
The drawings do not necessarily indicate or describe all
work required for full performance and completion of the
requirements of the Contract.
On the basis of the general scope indicated or described,
the trade contractors shall furnish all items required for the
proper execution and completion of the work.
Revisions:
Issue Date
01/20/09
Drawn By
KIA
Checked By
BKS
Drawing Title:
ELECTRICAL
DETAIL SHEET
Certified By
itST
Drawing Number:
5
0
L'Acquls Project Number:
08109