HomeMy WebLinkAboutM202 Kitchen Plan & Exhaust FanFAN FAN UNIT TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER 1 TYPE 0 UNIT NO. FAN UNIT MODEL MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) 1 NCA18HPFA NCA18HPFA 10.2 2450 1.750 1205 1.500 1 230 10.2 176.18 FAN UNIT NO. FAN UNIT TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER 1 TYPE 0 YES YES YES YES FAN UNIT NO. OPTION (Qty. Descr.) ROW 1 1 Wallmount 27.5 sq. x 2" HOOD CONFIG. END TO END ROW ALONE ALONE NO. TAG PACKAGE LOCATION SWITCHES ROOFTOP STARTERS OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT FLA 1 210110FP Wall Mount In SS Box Face Mount Right Side Hood 1 Light 1 Fan Exhaust On In Fire, Fans On /Off Thermostatically Controlled Exhaust 1 1.500 230 10.2 Hood 1 #11111 ,N issma imasm JOB CARMEL VFW LOC�1 TION 1 /12/09 JOB 893442 LAP IV .L) WO' 893442 .DRA WN BY RDR REV 1.00 HOOD INFORMATION HOOD NO. MODEL 5424 ND -2 LENGTH 12' 3.00" MAX. COOKING TEMP. 450 Deg. EXHAUST PLENUM TOTAL EXH. CFM 2450 RISER(S) WIDTH LENG. DIA. CFM S.P. 16" 2450 1.106" SUPPLY PLENUM TOTAL SUP. CFM 0 RI WIDTH LENG. DIA. CFM S.P. HOOD INFORMATION HOOD NO. FILTER(S) TYPE Stainless Steel (High E QTY. 3 5 HEIGHT 16" 16" LENGTH 16" 20" LIG QTY. 4 TYPE Screw In Halogen Bulb, WIRE GUARD NO UTILITY CABINET(S) LOCATION FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL SWITCHES QUANTITY LOCATION FIRE SYSTEM PIPING NO HOOD WEIGHT 687 LBS HOOD OPTIONS FAN OPTIONS IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. HOOD NO. OPTION LEFT END STANDOFF 3" Wide BACKSPLASH 80.00" High X 150.00" Long 430 SS LEFT SIDESPLASH 80.00" High X 54.00" Long 430 SS BACKSPLASH INSIDE CORNER 80.00" High X 4.00" Long 430 SS FIELD WRAPPER 6.00" High Front, Right RIGHT END PANEL 36" Top Width, 32" Bottom Width, 45" High 430 SS FAN ACCESSORIES EXHAUST RISER HANGING ANGLE 16" STAINLESS STEEL (HIGH EFFICIENCY) 3.00" INTERNAL STANDOFF GREASE DRAIN WITH REMOVABLE CUP END PANEL G P 4.0000 54.0000 BACKSPLASH 80.00" HIGH X 150.00" LONG 36.0000 EQUIPMENT BY OTHERS FIELD WRAPPER 6.00" HIGH 7 Z (SEE HOOD OPTIONS TABLE) SCREW IN HALOGEN ULB, STANDARD INCANDESCENT i 00 LIGHT FIXTURE 45.0000 SECTION VIEW MODEL 5424ND-2 CAPTIVE —AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING: NSF INTERNATIONAL ETL LISTED FILE# 3054804 -001 48.0' MAX 24.0000 NOM. 78.0000 102. AFF MIN. I 000 Cen ±rif uga C RO R HOOD CONSTRUCTION 430 SS Where Exposed fiff 54.0000 3.0000J B —3.0000 igh Press (Fan #1 F HT U.L. Listed Screw In Halogen Bulb 0 NOTE: PLAN VIEW Hood #1 12' 3.00" LONG 5424ND -2 Additional hanging angles provided for hoods longer than 12 ft. \CA1 8 r W us 16.0000 PFA) Al A, 4.1 16.0000 Field Cut 12' 3.00 "Nom. /12' 3.00 "OD FEATURES: WALL MOUNTED FANS RESTAURANT MODEL UL762 UL705 AMCA SOUND AND AIR CERTIFIED WIRING FROM MOTOR TO DISCONNECT SWITCH WEATHERPROOF DISCONNECT HIGH HEAT OPERATION 300 °F (149 °C) GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300 °F (149 °C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE —UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600 °F (316 °C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS: A ELECTRICAL PACKAGES ELECTRICAL PREWIRE PACKAGE DRAWING NUMBER 210110FP JOB NAME CARMEL VFW JOB NUMBER 893442 CONTROL INPUT 120VAC H1 =LINE, N1= NEUTRAL 15A BKR DO NOT WIRE TO SHUNT TRIP BREAKER 9 21 23 24 2 3 4 5 6 7 8 10 11 H1 BK BK 12 BK 13 14 16 17 18 INPUT 2 WIRE 1 PHASE 19 20 22 FS -01 BL F .2 I5 (Fan Switch Shown TI 04 CInsitalled) 18 11 15 0 OR Al A2 TI -04 DS Delay TIMER (30 min) R1 -1 BK N CO3„S 0 NO H2 Al WH WH DS -1 TI -04 DS1S -04 WH I Al A a Cl C 0 NC1t� BK NO �NO1tS BK� -_tiWH_ 0 LIGHT INPUT 120VAC H2 —H5 =LINE, N2 —N5= NEUTRAL 15 15A BKR LS -01 BR B 6,-BK WH -0 W cS 1 PHASE 230V C -1 L1 1 T1 21 WH 0N26\-- (EXH -1 GR 22 1 NOTE 1: DUCT THERMOSTATS FIELD WIRED WHEN RISERS SHIPPED LOOSE. IF MULTIPLE THERMOSTATS, THEY ARE WIRED DATE 1/12/2009 DRAWN BY 220V /1Ph, W/ 1 Exhaust Fan, Exhaust in Fire, Fan On /Off Thermostatically Controlled (One Stat Per Exhaust Riser). Label ST FS MS R1 LS GP TX GR DS Description Starter Fan Switch (Lighted) MicroSwitch (Ansul PyroChem) Relay DPDT Light Switch (1400W max) Hood Light(s) General Purpose Relay DPDT Transformer Contactor Ground Duct Thermostat (See Note 1) TI -04,07 Off Delay Timer RZ7- FSB3HU23 Spare Relay Contacts C -RD N0 -BL NC -PR 1 NC 3 4 NO 6 7 COM 9 A COIL B R1-R5 RELAY Spare Relay Contacts R2 -1 TERMINAL FOR FIELD NC C WIRING TO BUILDING FIRE PANEL, DRY CONTACTS FOR SIGNAL ONLY -ON 04(S -0NC4S ---0 C4 MS -1, MS -2 MicroSwitch Ansul Pyrochem C -RD C -RD NO -BK NO -BK NC -BR NC —BR SPARE RELAY CONTACTS CAN BE USED TO CONTROL ITEMS REQUIRING SHUT DOWN WHEN THE FIRE SYSTEM DISCHARGES, SUCH AS SHUNT TRIP, SIGNALS, ETC... 12 x 18 x 6 Box IN PARALLEL WITH DS -01 Motor Type PH Volt HP FLA BREAKER Exh -1 Exh 1 230 1.5 10.2 15 Amp BK BLACK BL BLUE BR BROWN OR ORANGE RD RED WH WHITE NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR YW YELLOW GY GRAY PR PURPLE OR /BL ORANGE /BLUE (STRIPE) BL /RD BLUE /RED (STRIPE) RD /GN RED /GREEN (STRIPE) DRAWING SHOWN DE- ENERGIZED NOTE: IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM MICROSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED. CA ;4' W 1.4 w z C z z 4t o 0-4 U Carmel Redevelopment Commission 111 West Main Street Cannel, Indiana 46032 317.571 -2787 (ARTS) IH W 0 a co C Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Revisions: Issue Date 01/20/09 Drawn By oso Checked By AJ M Drawing Tide: Kitchen Hood And Exhaust Fan Drawing Number: 2 i ,I 2 L'Acquis Project Number: 08109