HomeMy WebLinkAboutC4.2 Details0 d (MIN) 27' E SMALLER 3 50' TO 60' 4 66" LARGER 6 0 d VAIN) 27' f SMALLER 4 30' TO 60' 4 64' 4 LARGER 4 FITTING REARING AREA REQ'O. 0 -45 2.0 SQ. FT. BEND 45 -90' 5.5 SQ. FT. bEND 0 S N E 8 I- 0 L EDGE OF PAVEMENT. CURb GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT -OF -WAY LEGEND bc= OUTSIDE DIAMETER 0= INSIDE DIAMETER d= DEPTH OF bEDDING MATERIAL bELOW PIPE MANHOLE STEPS AT 16' MAX. ON CENTER. (SEE DETAIL) PRECAST MANHOLE SECTION GROUT SLOPE DISTANCE DEFINED by O.O.T. REQUIREMENT IF WITHIN 5' OF EDGE OF PAVEMENT, USE "b" bORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DEN SITY FOR ENTIRE TRENCH bACKFILL 1/2" CEMENT MORTAR 0 4' MIN. MIN. 6' TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT NOTE: ALL INITIAL bACKFILL SHALL bE INSTALLED IN 6 T012" bALANCED LIFTS. A MINIMUM 9' OF CLEARANCE SHALL bE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. DEPTH OF bEDDING MATERIAL bELOW PIPE REINFORCED CONCRETE PIPE (RCP) lFDD IN4 DETAIL NOT TO SCALE SEE PLANS OR STRUCTURE DATA TAbLE FOR TYPE OF CASTING Gi or ADE 5' MIN. g. o: Asti n000 COVER ..A n #4bARS•6 O.C. 6" "b' bORROW BOTH WAYS TOR PRECAST bOTTOM ONLY) MAN H OLE TYPE,,." C" C STORM SEWER NOT TO SCALE CONCRETE GRADE D RINGS AISE TO FINISH G 1 MA, ALLOWABLE HEIGHT OF RISE PRECAST ECCENTRIC CONE CONCENTRIC CONE OR PRECAST COVER. 4" MIN. 6 bARREL SECTION -48' DIA. ASTM C -478 CLASS A REINFORCED CONC. PIPE 4000 PSI rW 3 0 11- 1 b CEMENT GROUT MIN. 12' 1 /6bc d PIPE THIcKNES5 /0 +2 IF NOT WITHIN 5' Or EDGE OF PAVEMENT: USE b bORROW COMPACTED TO 90% STANDARD PROCTOR DENSITY TO 1/6 OF PIPE DIAMETER AND REGULAR bACKFILL TO TOP OF TRENCH HYDRANT STYLE AND PATTERN TO BE AS SPECIFIED bURY LINE MARKED ON HYDRANT FINISHED GRADE CLEAN +r'9 GRAVEL OR CRUSHED STONF bACKFILL TO 12 ABOVE PORTS, AND 12' BELOW BASE OF HYDRANT TOP OF CONCRETE TO bE bELOW DRAIN PORT CONCRETE BACKING FLAT STONE OR CONCRETE bUTri RUbbER bASE EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT -OF -WAY C.L. MANHOLE FRAME AND COVER NEENAH R1T12 -b -SP OR EQUAL UNLESS OTHERWISE NOTED. EXTERIOR bACKPLASTER MANHOLE STEPS AT 16" ON CENTER (SEE DETAIL) GROUT FILL MINJMUM SLOPE 1/2 PER FOOT 3' MINIMUM MIN. a' UNDER PIPE 12' OF 12 STONE bEDDING UNDER bASE IF WITHIN 5' OF EDGE OF PAVEMENT, USE -8 CRUSHED STONE OR APPROVED EQUIV. CLASS I bEDDING MATERIAL HAND TAMPED OR WAi.KED INTO PLACE TO MIN. OF 1i AbOVE TOP OF PIPE, AND "b BORROW COMPACTED TO 95% STANDARD PROCTOR DENSITY TO TOP OF TRENCH. LEGEND bc= OUTSIDE DIAMETER D= INSIDE DIAMETER d= DEPTH OF bEDDING MATERIAL bELOW PIPE HYDRANT.. M l6 DETAIL NOT TO SCALE CAST C C C SANITARY NOT TO SCALE NOTE: MIN. 6' TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT ALL INITIAL bACKFILL SHA1.1 bE INSTALLED IN 6 T012 bALANCED LIFTS. A MINIMUM 9' OF CLEARANCE SHALL bE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. DEPTH OF bEDDING MATERIAL bELOW PIPE PLASTIC PIPE PVC HOPE) bEDDING DETAIL NOT TO SCALE MOUNT PUMPER NOZZLE TOWARD ROADWAY NOT TO EXCEED 12'. CONCRETE GRADE RINGS UTILIZED TO RAISE TO FINISH GRADE K ALL RING'S E CASTING. BETWEEN PRECAST ECCENTRIC CONE TOP UTILIZE KEN -SEAL NO. 2 ANO RING JOINT (SEE DETAIL) BUTYL RUbbER bA1E EXTERIOR BACK PLASTER 6 ABOVE AND bELOW JOINT bREAK OUT TOP HALF OF PIPE AFTER MANHOLE IS CONSTRUCTED OR FORM NEAT CHANNEL AS SPEC.. TOP OF CONC. bASE AT SPRING LINE OF PIPE WHERE POURED IN PLACE. +4.12' O.C. bOTH WAYS MIN. 12" IF NOT WITHIN 5' Of' EDGE OF PAVEMENT, USE 18 CRUSHED STONE OR APPROVED EQUIV. CLASS I BEDDING MATERIAL HAND TAMPED OR WALKED INTO PLACE TO MIN. OF 12" AbOVE TOP OF PIPE, AND REGULAR bACKFILL TO TOP OF TRENCH. PRECAST CONC. OR POURED IN PLACE bASE. NOTE: PROVIDE A NEOPRENE CONICAL -TYPE FLEXIBLE SEAL FOR ALL PIPE TO MANHOLE CONNECTIONS. SEAL SHALL MEET ASTM C 445 bACKFILL PER SPECIFICATIONS CONCRETE COLLAR bEDDING MATERIAL 111611 III iii iii ii i= 111 iI iii 7 r iii- i iii ii�in I TOP VIEW THRUST bLOCK DETAIL NOT TO SCALE PLAN EXITING GROUND AT PIPE 0 45' WYE FITTING v 45' ELbOW SEWER MAIN ELEVATION LATERAL DETAIL NOT TO SCALE HEAVY DUTY LAMPHOLE CASTING W/ SOLID LID, NEENAH R-1974 OR EQUAL 45' bEND 1/40 CONCRETE CRADLE CLEANOUT DETAIL NOT TO SCALE NOTE: CLASS 'A' BEDDING TO bE UTILIZED FOR AU. CLEANOUT INSTALLATIONS (SEE DETAIL) iI1- 1I1= t I1= 1I1 1If =1I1 I 1 =1 11 =1 11 1 11 =1 11 =1 1 1 =1 11 1 11 1 1 =1 11 11 1 =1 1 1 =1 11 =1 11 =1 11 =1 I I I i, d I 1 =1I1 =1 III 1= 1T_I -1I BEARING AREA I I— SIDE VIEW LATERAL 300 275 250 225 200 SLOPE 175 LENGTH 150 FT. 125 100 75 50 25 sl D b p,G L...ET NOT TO SCALE A r_ 5' NOTES: 1. SANDBAGS OF EITHER bURLAP OR WOVEN GEOTEXTILE FABRIC, ARE FILLED WITH GRAVEL, LAYERED AND PACKED TIGHTLY 2. bAGS SHALL bE LAYERED 2 OR 5 HIGH 5. LEAVE ONE SANDBAG GAP IN THE TOP ROW TO PROVIDE A SPILLWAY FOR OVERFLOW. 4. SANDBAG'S TO bE USED AFTER PAVEMENT IS INSTALLED. PRIOR TO PAVEMENT INSTALLATION, STRAW bALE PROTECTION TO bE USED. 5. SANDbAGS SHALL BE PLACED AND MAINTAINED AROUND NEWLY CONSTRUCTED DRAINAGE STRUCTURES TO PREVENT SILT AND DEBRIS PROM ENTERING DOWNSTREAM DRAINAGE FACILITIES DURING ALL CONSTRUCTION AND SHALL REMAIN IN PLACE UNTIL SITE WORK IS COMPLETED. x x x 1 STAPLE PER SQ. YD. 11/2 STAPLES PER SQ. YD. GENERAL 'STAPLE RECOMMENDATIONS b A C b A C b C C 4 :1 5:1 2:1 SLOPE GRADIENT SAND SAGS EROSION CONTROL MAT INSTALLATION GUIDE DETAIL NOT TO SCALE EXTEND FAbRIC WIRE TO 4" BELOW SURFACE x x x x x x 1 :1 FILTER FABRIC b NON WOVEN GEOTEXTILE FAbRIC FLOW 3' CHANNEL LINING If /a tV NOTES CHANNEL LININGS UTILIZE STAPLE PATTERN 'C' WITH ADDITIONAL STAPLES ON SIDE SLOPES AT PROJECTED WATER LINE. STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS. STAPLE PATTERNS MAY VARY DEPENDING UPON SOIL TYPE AND AVERAGE RAINFALL. AT SLOPE LENGTHS GREATER THAN 500 FEET OR WHERE DRAINAGE OVER LARGE AREAS IS DIRECTED ONTO THE bLANKETS. STAPLE PATTERN "C" SHOULD bE UTILIZED. SPACE POSTS PER I MANUFACTURER �1 RECOMMENDATIONS —=III =III WIRE WOOD POST 3' x ADDITIONAL STAPLES AS REQUIRED DUE TO DEPTH OF FLOW 2 STAPLES PER SQ. YD. SILT FENCE CONSTRUCTION NOT TO SCALE C II17 II III I I I=I I NOTE: POSTS SHALL HAVE A MINIMUM LENGTH OF 36 INCHES PLUS bURIAL DEPTH. POST MATERIAL SHALL bE WOOD, STEEL, OR SYNTHETIC, AND SHALL bE LOADS OF S UFFICIENT STRENGTH TO RESIST DAMAGE DURING INSTALLATION AND TO SUPPORT APPLIED FAbRIC SHALL bE A WOVEN GEOTEXTILE FAbRIC CONSISTING OF STRONG, ROT RESISTANT, MATERIALS RESISTANT TO DETERIORATION FROM ULTRAVIOLET AND HEAT EXPOSURE. LU V o Osie (1) aN 01s w Z N O� cc m1- Z tu 44 0 �m 0 0. co Q cc W 0 C5 cct:) 44e: p �atunrrrury� i l Q• G.srE.... a� No. 9700328 -3 STATE OF pc� NDI ANA CERTIFIED B co I— LU Z Q 3 a Q a O Ed J o W W a O cla W cc N �a x DATE: DRAWN BY: CHK'D BY: JOB NO. 01 /06/03 KAM DCG IN 2003 --0113 REVISIONS SHEET NO. C4.2 OF I N 2003.0113.071.0 21.S P.dwg