Loading...
HomeMy WebLinkAboutC7.1 Site DetailsID BLOCKING FOR PLUGS AND BENDS BLOCKING FOR PLUGS AND BENDS PIPE SIZE OUTSIDE FACE AREA (SQ. FT.) ZS ROW, SUITE E PHONE: 317-244-1968 INDIANA 46241 FAX: 317-244-1969 SIZE OF OUTSIDE FACE AREA (SQ. FT.) PLUG 90' 45' 22 1/2' 11 1/4' RUN BRANCH 20" 16" 30 T MAIN STI LUMBUS, C 38 33 60 20" OR 16" 16" 12 12" 7 10" 6 12" totli1 11 1 1 s !'s M. p 1'% N 9 PE910337 S STATE OF Z .-3•. 6S /ONAI-EN, s �IIIIi i' DATE: 8" 5 10" d- d- N DSCE ERCE D] ,INDIAN 12" OR LESS 12 EE 8" 10" 6 8" 4 6" m DWN BY: AC H CHKD. BY: JMP SCALE: NONE DATE: 0 1 -27-2003 PROJECT NUMBER 02-123 DESIGN PHASE CONSTRUCTION PLAN NUMBER C7.1 SHEET OF ID BLOCKING FOR PLUGS AND BENDS BLOCKING FOR PLUGS AND BENDS PIPE SIZE OUTSIDE FACE AREA (SQ. FT.) SIZE OF SIZE OF OUTSIDE FACE AREA (SQ. FT.) PLUG 90' 45' 22 1/2' 11 1/4' RUN BRANCH 20" 16" 30 60 38 33 60 20" OR 16" 16" 12 12" 7 10" 6 12" 8" 5 10" d- d- N 12" OR LESS 12 7 8" 10" 6 8" 4 6" 6" 2 4" 4" 2 ID d (MIN) 27" SMALLER 3" 30" TO 60" 4 66" LARGER 6" DIMENSIONS (INCHES) A (MAX) B (I.D.) C (MIN) 18 48 25 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 DIMENSIONS (INCHES) A (MAX.) B (I.D.) C (MIN.) 18 48 25 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 ILL AD "Mr lw (Ms 0 i :j 41 c� 00 0 rO% 0 r 0 0 11 1 0 0 0 0 0 WALL SLEEVES OR GROUT (TYP.) UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE A7\11 WV A HO. IIA 6" STONE BASE OR CONCRETE W/ SUMP STRAP IRON ANCHORS 2" WIDE x 1/2" THICK PLAN ACCESS HATCH INGRESS EGRESS LADDER 90 FLANGED BEND BALL VALVE W/ FLANGED END REDUCING FLANGE DOUBLE DETECTOR CHECK VALVE FLANGED OS Y VALVE FIRE LINE DOMESTIC SERVICE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 22 1/2' AND 11 1/4' BENDS UNDISTURBED EARTH 5" DIA. WASHER, 1" THICK 3/4" x 18" ANCHOR BOLTS (4 REQ'D) DOWNWARD BEND NOT LESS THAN 0.6 x LAYING LENGTH MASTER WATER METER PIT DETAIL NO SCALE 2,000 LB. MIN. CONCRETE PLAN PIT TYPE POST INDICATOR SECTION "A -A" MECHANICAL JOINT GATE VALVE BOX 0 TAPPING SLEEVE W/ TAPPING VALVE BOX LOK -PAK ASSEMBLY TURBINE METER FLANGED AT BOTH ENDS (BY CHECK VALVE FLANGED TEE DOUBLE CHECK VALVE UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE UNDISTURBED EARTH LEGEND por OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? AND 45? BENDS SECTION "C -C" PLAN OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE. NOT LESS THAN 0.75 x LAYING LENGTH T PIPE SUPPORTS (2 REQ'D) WATER MAIN CONCRETE BLOCKING NOT TO SCALE 6" FIRE LINE 4x2 1/2x2 1/2 FIRE DEPT. CONNECTION MHO 2,000 LB. MIN. CONCRETE 2" DOMESTIC SERVICE LINE PER MEP SECTION "D -D" EXISTING GRADE UTILITY) 1" 0\ 2,000 LB. MIN. CONCRETE UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR PLUGS. 6" TEE REDUCER NOTES 1. CUSTOMER SHALL CONSTRUCT METER VAULT 2. CONSTRUCTION MATERIALS: CONCRETE, 8 "x8 "x16" CONCRETE BLOCKS AND MORTAR OR PRECAST 3. INSIDE DIMENSIONS PER DRAWING NOTES. VAULT TO BE SET LENGTHWISE WITH SERVICE. 4. TOP OF VAULT TO BE CONCRETE, AT LEAST 4" THICK WITH REINFORCING. WHEN VAULT IS CON SRUCTED IN PAVED AREAS, PAVEMENT IS TO BE LEVEL WITH TOP OF VAULT, AND THE TOP REIN- FORCED AS REQUIRED TO SUPPORT TRAFFIC LOADS. WHEN VAULT IS CONSTRUCTED IN GRASS PLOT, TOP OF VAULT SHALL CORRESPOND WITH FINISHED GRADE LEVEL OF SURROUNDING AREA. 5. BOTTOM OF VAULT TO BE MINIMUM OF 6" OF CRUSHED STONE WITH MINIMUM CLEARANCE OF 12" BELOW BOTTOM OF FIRE /SERVICE LINE. 6. CUSTOMER SHALL FURNISH 2" BALL VALVES ON OUTLET SIDE OF THE 2" METER SETTING. 7. CUSTOMER SHALL FURNISH DOUBLE DETECTOR CHECK VALVE AS APPROVED BY THE INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT, WITH BY -PASS METER AND RESILIENT SEAL GATE VALVE ON OUTLET SIDE OF CHECK VALVE. 8. CUSTOMER SHALL FURNISH VAULT FRAME AND LID TO BE INSTALLED IN TOP OF VAULT BY CUSTOMER (BILCO 30 "x30" ALUMINUM PCM. 9. WATER COMPANY WILL INSTALL DOMESTIC SERVICE INTO THE METER VAULT AND INSTALL METERS. 10. CUSTOMER SHALL INSTALL A LADDER IN PIT FOR INGRESS AND EGRESS. METER 12" FIRE HYDRANT VALVE 4" FIRE PROTECTION LINE UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR TEES AND WYES PLAN 2' -0" MIN. TO CURB OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? 10" MOVING EDGE 6" TOPSOIL PRECAST MANHOLE SECTIO CONCRETE FOOTING MAXIMUM OPENING 4" GREATER THAN O.D. OF PIPE ,1- z w 6 0a M w 0 STOP SIGN INSTALLED IN LANDSCAPE AREA 6" MINIMUM 6" MANHOLE STEPS REQUIRED IF DEPTH EXCEEDS 4' -0" (AT 16" MAX. ON CENTERS) ■1 1■I■1■ i T s_A w_ sr z 1 CO 2Z0j zm w W Mw =o V� v NEENAH R -3010 w I- r EE r o o 1 B NON- SHRINK G ROUT CURB MANHOLE NOT TO SCALE 10" #4 REBAR 6" 0.C. EACH WAY PAVING BASE CONCRETE FOOTING HANDICAP, NO PARKING SIGN INSTALLED IN PARKING LOT. HANDICAP LOCATIONS 2 -SIDED WHERE STALLS FACING. 2" STEEL PIPE, ROUND OR SQUARE, SET IN CONCRETE 6" STEEL PIPE FILLED W /CONCRETE PAVEMENT 8" PRECAST REDUCER CAP BARREL SECTION ASTM C -478 CLASS A REINFORCED CONCRETE PIPE 4000 PSI 4" COMPACTED #53 STONE #8 COMPACTED STONE EDGE OF PAVEMENT, CURB- GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT -OF -WAY HEAVY DUTY LAMPHOLE CASTING W/ SOLID LID, NEENAH R• -1974 OR EQUAL COMPACTED SOIL BACKFILL CONCRETE COLLAR J_ 0 0 INSTALLATION REQUIRED 1. EXTENDING 20' FROM STORM INLETS OR MANHOLE WHERE SHOWN ON THE UTILITY GRADING PLAN. 2. PIPE MATERIAL PER INDIANA DEPT. OF TRANSPORTATION SPECS. No. 718.02 IF WITHIN 5' OF EDGE OF PAVEMENT, USE "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY FOR ENTIRE TRENCH BACKFILL LEGEND OD OUTSIDE DIAMETER ID INSIDE DIAMETER d DEPTH OF BEDDING MATERIAL BELOW PIPE MAX. OPENING 4" GREATER THAN 0.D. OF PIPE NEENAH R -1772 1/2" CEMENT- MORTAR 6" MIN. PRECAST MANHOLE SECTION NOTE: MAXIMUM CLEANOUT SPACING TO BE NO MORE THAN 100 FEET. #8 WASHED STONE WYE CLEANOUT DETAIL NOT TO SCALE rTh MIN. DISTANCE DEFINED BY D.O.T. REQUIREMENT MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT MINIMUM WIDTH 1.25 OD 12" DEPTH OF BEDDING MATERIAL BELOW PIPE PAVEMENT LAWN AREA AREA 0" MAX. 45' BEND 4" PIPE UNDERDRAIN UNDER PAVEMENT NOT TO SCALE d REINFORCED CONCRETE PIPE (RCP BEDDING/TRENCH DETAIL NOT TO SCALE MIN. ONCRETE "0" RINGS 6" #4 REBAR 6" 0.C. EACH WAY MANHOLE STEPS REQUIRED IF DEPTH EXCEEDS 4' -O" (AT 16" MAX. ON CENTERS) FLEXIBLE PIPE a SLEEVE V a D PAVEMENT v 4" DIAMETER PERFORATED HIGH DENSITY POLYETHLENE PIPE WITH "HIGHWAY SOCK FILTER" IF NOT WITHIN 5' OF EDGE OF PAVEMENT: USE "B" BORROW COMPACTED TO 90% STANDARD PROCTOR DENSITY TO 1/6 OF PIPE DIAMETER AND REGULAR OD BACKFILL TO TOP OF TRENCH #8 STONE OR APPROVED EQUIVALENT BEDDING MATERIAL HAND TAMPED OR WALKED INTO PLACE. NOTES: 1. ALL INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS. 2. A MINIMUM 9" OF CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. 8" PRECAST REDUCER CAP NON- SHRINK GROUT BARREL SECTION ASTM C -478 CLASS A REINFORCED CONCRETE PIPE 4000 PSI 4" COMPACTED #53 STONE 4' MIN. SEE UTILITY PLAN FOR INVERTS 1