HomeMy WebLinkAbout05060041 C203 Utility PlanNOTES: 9. 10. 11. 12. EXISTING SPOT ELEVATION CONTOUR MANHOLE /INLET INLET PIPE END SECTION AREA /STREET LIGHT TELEPHONE RISER ELECTRIC RISER UNDERGROUND TELEPHONE UNDERGROUND ELECTRIC WATER LINE WATER VALVE FIRE HYDRANT WATER METER GAS LINE GAS VALVE GAS METER DECIDUOUS TREE /BUSH EVERGREEN TREE /BUSH TREE /SHRUB LINE =LEGEND= 1. UTILITY COMPANIES: SBC AMERITECH CINERGY PUBLIC SERVICE OF INDIANA CLAY REGIONAL WASTE (SANITARY SEWER) CARMEL WATER COMPANY VECTREN PROPOSED SANITARY SEWER SANITARY SEWER CLEANOUT STORM SEWER STORM INLET ELEC ELECTRIC SERVICE LINE UNDERDRAIN WATER MAIN WATER SERVICE FIRE HYDRANT WATER VALVE 110.11111•.•M r 2. SEE MECHANICAL PLANS FOR LOCATION AND SIZE OF SANITARY DRAINS, WATER LINES AND FIRE PROTECTION WITHIN BUILDINGS. 3. PLUMBING CONTRACTOR TO VERIFY WATER PRESSURES. WATER SERVICE SIZE AND METER SUBJECT TO REVIEW AND REFINEMENT. FINAL WATER SERVICE SIZE AND METER SIZE TO BE DETERMINED BY PLUMBING CONTRACTOR /ARCHITECT. 4. COMPACTED GRANULAR BACKFILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE ALL MAINS, CONDUITS, SERVICE LINES, ETC., IN THE AFFECTED CONSTRUCTION AREA. EXISTING UTILITY STRUCTURES ARE SHOWN HERE IN ACCORDANCE WITH AVAILABLE INFORMATION. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES AND FACILITIES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY) IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6. RCP REINFORCED CONCRETE PIPE CLASS III PVC POLYVINYL CHLORIDE SANITARY SEWER ASTM D- -3034, SDR-35 HCSP HELICAL CORRUGATED STEEL PIPE 16 GAUGE ALUMINIZED HDPE CORRUGATED HIGH DENSITY POLYETHYLENE PIPE (SMOOTH FLOW) 7. FLEXIBLE PIPE TO BE INSTALLED PER ASTM D -2321, CLASS 1,2, OR 3 BEDDING. RIGID PIPE TO BE INSTALLED PER ASTM C-12. 8. 10 LINEAL FEET OF 4" SUBSURFACE DRAIN REQUIRED EACH WAY (UPGRADE) FROM ALL STORM INLETS (UNLESS OTHERWISE NOTED ON PLANS). FOR SITE DETAILS SEE SHEETS "C801", "C802" AND "C803 FOR SITE SPECIFICATIONS SEE SHEET "C901". FOR SOIL EROSION AND CONTROL DATA SEE SHEET "C803". ALL CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT CITY OF CARMEL STANDARD SPECIFICATIONS, LATEST EDITION. 13. SEE MECHANICAL /PLUMBING PLANS FOR SIZE OF DOMESTIC AND FIRE PROTECTION WATER LINES. 14. PROPOSED 12" WATERLINE BY CARMEL UTILITIES TO BE INSTALLED ON THE RIGHT -OF -WAY LINES. ti it t l` t t\ tk\t i \\it 11 \s t\,i �1 i 1\i I t t tl\ lit t1 ti 11 t 1 t 11 1 I t tt I ti t i\ 1 t t it 11 t i j l u it t t 1 1 1 11 i t 11 �\t 111 4 t 11 11 11 u ii w \r u 1 11 \t t t t l I 1 t i t 111 i� t 3 i 1 11 TYPE I CLEAN OUT TC. 851.0 INV. ELEV. 845 00 4" SSD 4�SSD -1- STORMTEC ISLAND (EAST) STORMTECH UNDERGROUND STORAGE 19 ROWS x 11 CHAMBERS (91'x80) BO OM UNI 2.95 2 v E7 a a.= 3.0 10 D 1 V- .7 00 FL+ a r y V 844. 1 TYPE I CLEAN OUT It. 851.0 INV. ELEV. 845.00 FINISHED FLOOR ELEV. 851.50 18" STORM RCP (BY OTHERS STORMTEC ISLAND (WEST) STORM UNDERGROUND STORAGE 29 ROWS x 12 CHAMBERS (140'x90') AN 9 RAYS x 4 CH BER (45x30') BO OM UNI 8 3.50 2YR Ea.= ;43.8E 10 FL+ +s; E 1 844.73 00 FL i D V. 846.: 2 II••II•uII ••11 ••11 •.IIa\II•.IIuI1••1111•/1 mum ■..auuui■■ immo■ mum ■u.u.u.,.i.au.i.iai• N w A A A REVISIONS /11/06 REVISED PER COMMENT LETTER DATED 1/10/06 AND ADDED SHEET C402 MG TYPE I CLEAN OUT TC. 853.3 INV. ELEV. 847 10' BUILDING U CONTRACTOR SHALL RELOCATE ALL EXISTING UTILITIES ON SITE STREET GARAGE FINISHED FL 851.50 ED FL 851.50 FINISHED FLOOR ELEV. 853.50 STREET "B" 0 BUILD! TYPE I CLEAN OUT TC. 853.5 INV. ELEV. 847.00 DRAWING: DATE: PROJ. NO.: DRAWN BY: SHEET NO.: TUBE FILE 2308203 08/18/04 2308 cEj !1 11 11 11 11 11 11 11 11 11 11 11 11 11 1 11 11 4 j ll i /1 1 11 /I ll 11 11 11 1I I1 1/ I w Z w J 0 U 1/ 1/ 11 1/ 11 I/ 11 I II 11 1 1/. 1 I 1 I 1 E/T I 011E cza. 00 r 2 c1 I 0 -J r N u 0 G) O L C c .F .ri bJ c 5 U p 0 N a) 0 0 0 0 U �t- 00 4- 0