HomeMy WebLinkAbout05060041 C501 Sanitary Plan & Profile850 840 16 +00 BENCHMARK RM 209 -1. CHISELED SQUARE CUT IN SOUTHERN DOWN STREAM HEADWALL OF CSX RAILROAD (NOW MONON TRAIL). CULVERT FOR CARMEL CREEK ELVE, 829.43 LATERAL NOTES: 1. WYES AND LATERALS TO BE 6" PIPE UNLESS OTHERWISE SPECIFIED. 2. ALL WYE CONNECTIONS SHALL HAVE A MINIMUM OF FIVE FOOT LATERAL EXTENSION CONNECTED TO THE WYE. THE END OF THE LATERAL SHALL BE PLUGGED OR CAPPED. 3. LATERALS RUNNING TO THE OPPOSITE SIDE OF STREET SHALL EXTEND TO WITHIN 5 FEET OF THE BUILDING LINE. 4. NO FOUNDATION OR OTHER STORM WATER DRAINS SHALL BE INTERCONNECTED TO THE SEWER LATERAL INSTALLED AND CONNECTED TO THE DISTRICT'S SANITARY SEWER. 5. CONTRACTORS SHALL LAV 14 GAUGE STRANDED WIRE THE ENTIRE LENGTH OF THE LATERAL. WIRE IS TO BE PLACED ON TOP OF THE LATERAL. THE DISTRICT INSPECTOR WILL VERIFY PLACEMENT OF THE WIRE. AFTER INSPECTION, BEDDING IS TO BE PLACED ON TOP. GENERAL NOTES: 1. ANY PIPE INSTALLED AT LESS THAN MINIMUM GRADE AS SPECIFIED BY TEN STATES STANDARDS WILL NOT BE ACCEPTED BY THE CLAY TOWNSHIP REGIONAL WASTE DISTRICT. 2. ALL SANITARY SEWER WITH LESS THAN 6.5 FEET OF COVER TO HAVE AT LEAST ONE INFILTRATION /EXFILTRATION TEST AFTER ALL UTILITIES HAVE BEEN INSTALLED. THIS DCAM REQUIREMENT WILL BE COMPLETED PRIOR TO ACCEPTANCE FOR PUBLIC MAINTENANCE UNLESS WAIVED BY DCAM. 3. S.E. EXCLUSIVE SANITARY SEWER EASEMENT D. U.E. DRAINAGE AND UTILITY EASEMENT D.S.& U.E. DRAINAGE, SANITARY SEWER AND UTILITY EASEMENT 4. MANHOLES PROPOSED TO BE INSTALLED IN UNPAVED AREAS SHALL BE CONSTRUCTED SUCH THAT THE TOP OF CASTING (T.C.) IS A MINIMUM OF THREE (3) INCHES ABOVE THE FINISHED GRADE TO PREVENT PONDING OF WATER OVER THE CASTING. POSITIVE DRAINAGE AWAY FROM THE MANHOLE SHALL BE PROVIDED. 5. THE LOWEST FINISHED FLOOR ELEVATION SERVED MUST BE ONE (1) FOOT ABOVE THE TOP OF CASTING (T.C.) OF EITHER THE UPSTREAM OR DOWNSTREAM MANHOLE PER t`_ SECTION 13.02.A.2 OF THE CLAY TOWNSHIP REGIONAL WASTE DISTRICT STANDARDS FOR THE DESIGN AND CONSTRUCTION OF SANITARY SEWERS, MAY 1989. NORTH 1" 50' HORIZ. 1" 5' VERT. 15 +00 14 +00 13 +00 0) N 12 +00 #ali #a #e1 ■•liaa IS HMI la# 0 ;rM 11""'"- 4'$ 731 4 SSD NON a a #a•••*aa# •a• !•Ma■#aa a •a *Mlaaa a a FINISHED FLOOR ELEV. 853.50 AN SO RM RW5 EEC ISL i AND (WE(45 S STORNTE(H UND STORAGE 29 ROA6 x 12 CHAMBERS (14(}x90') x 4 O 8O U 2 y Z3 r O a ;V. R 00 �.1 7 TYPE BEAN OUT TC. 853.5 INV. BEV. 867.00 EAST 116th STREET TYPE BEAN CUT 1c. 851.0 INV. ELEV. 84 MTEC LAND EA (S SFORMT UHUERGROU STOR 19 ROW$ x 1 CW 7'iS (9 1'X80) T} AGE BO O14 UNi 8 Z95 2 LLo ++3x.� O to {I, i, r s 4 7 OO FL•+ II 844. 1 FINISHED FLOOR ELEV. 851.50 J 1 aGT L C' STREET 1 "C" La gig 1 FINISHED FLOC ELEV. 853 40 TYPE I KM OUT TC. 853`3 INV. ELEV. 847 11+00 10 +00 N 0) STREET "E" 9 +00 z Q 8 +00 7 +00 NG SANITARY MANHOLE T.C. EEEV. 849.99 8ENCNWALL ELEV. 835.99 INV. 8' PVC E 835.56 INV. 8' PVC W. 835.51 CONTRACTOR MUST FIELD VERIFY ELEVATION OF EXISTING WATER MAIN AND FIBER OPTIC PRIOR TO CONSTRUCTION. 6 +00 STREET "E" .I.. 18 COMPACTED GRANULAR BACKFILL REQUIRED INV. ELEV. 843.59 PROPOSED 15" RCP INV. ELEV. 844.44 PROPOSED 15" RCP /////7 41 PROPOSED 8" PVC SDR -3 (E) INV. ELEV. 837.39 "Bench wall must extend across the entire width of the manhole with a grouted flow transition at far wall to the top of bench wall" 352 LF OF 8" PVC SDR -35 1.57% 40.37 ALL BENCHWALLS MUST EXTEND TO CROWN OF HIGHEST INFLUENT PIPE 354 LF OF 8" PVC SDR -35 0.45% 72 LF OF 8" PVC SDR -35 0.45% PRIOR TO BACKFILLING, CONTRACTOR MUST COORDINATE WITH SURVEYOR TO OBTAIN AN UPSTREAM AS -BUILT INVERT ELEVATION AND ACCURATE HORIZONTAL LOCATION. CONTRACTOR TO MARK END OF STUB LOCATION WITH PAINTED GREEN 2 "X4 COMPACTED GRANULAR BACKFILL REQUIRED I NIIN CONTRACTOR TO CORE EXISTING MANHOLE AND REFER TO CTRWD SPECS SHEET C901. CONTRACTOR MUST INSTAL A BENCHWALL IN THE EXISTING MANHOLE WHICH SHALL EXTEND TO THE CROWN OF THE HIGHEST INFLUENT PIPE. CONTRACTOR MUST CONTACT CARMEL AFTER COMPLETION ON FIRST JOINT TO OBTAIN AS -BUILT INVERT ELEVATION OF THE CORE. AFTER COMPLETION OF WORK, CONTRACTOR MUST VACUUM TEST MANHOLE. 354 LF OF 8" PVC SDR -35 0.45% 5 +00 850 840 860 4•SSD n I! UGE Sanitary sewer shall be open cut for installation and Contractor must keep at least one travel lane open at all times EXISTING 8" SANITARY MAIN (E) INV. ELEV. 835.56 L. EXISTING 8" SANITARY MAIN (W) INV. ELEV. 835.51 oxi4 0 c 0 0 0 0 J 0 W v 0 in N (0 0 0 0 0 O N 0 a) N 0o 1n N 17) 0 LL C) (D 0 0 N N In N 1 0) 0 w 0 1- 0 IJ 0 cr 0 w W co 2 w z w U W W H v) Z i-- c0 z REVISIONS 1/11/06 REVISED PER COMMENT LETTER DATED 1/10 /06 AND ADDED SHEET C402 MG �N� F J kh,9 ti `�P. c. GtSTfRe O• 4, f z. i No. 1. 10302066 -0% STATE OF 1/11/1111 DRAWING: 2308501 DATE: 12/16/05 PROJ. NO.: 2308 DRAWN BY: MG SHEET NO.: C501 i_ii TUBE FILE