Loading...
HomeMy WebLinkAboutC2 Site Detail PlanEX. SAN. M.H. 3 6.°A; vkl020.00 2" UTIL. O STUB 1 0. o NEW STORM STRUCTURE #1 TRASH ENCLOSURE WALK -IN COOLERS TEE CONNECTION TO STORM SEWER PROPOSED BUILDING E ORM INLET 00 R2.50 L. F.4.44: R.C.P. R2.50' NEW STORM STRUCTURE #3 EX. 24" R.C.P. EX. 24 R.C.P. R2.50' CU I NEW ATERAL CON TION UTILIZ XIST LATE AL STUB PO E/E TS. FTE 8" TER ETER P INS LL PVB APPROXIM LOCA+ ION OF EXISTING W TER NE PROPOSED LATERA CONNECTION 36 00 (2) 1 WATER ME R PITS 3e TEE LIN I STAL 3/4" 10111Ski° SERVI WI 8" TER l TER •I FROM TEE FOR 'RIGA I SY M M INS 1 LL 2 TER VALVE W rd I SWI OINT FTER TAP °ROPO ER LINE EX. CURB INLET CUT EXISTING CURB FOR NEW ENTRANCE, REPLACE. CURB WITH DEPRESSED C RB. CONCRETE SLAB TO HAVE MINIMUM OF 1% SLOPE TO FLOOR DRAIN WITHIN "OPEN -AIR" DUMPSTER AREA, T.B.M. SEE NOTE) ROOF -DRAIN CONNECTION, CLEANOUT REQUIRED WITHIN 4 -FEET OF BUILDING. (TYP.) TIE INTO AREA DRAIN FROM DUMPSTER AREA. CUT EXISTING CURB FOR NEW ENTRANCE, REPLACE CURB WITH DEPRESSED CURB. EMPLOYEE PARKING SPACES PROVIDED 12 CUSTOMER PARKING SPACES PROVIDED 79 HANDICAPPED PROVIDED 4 TOTAL SPACES PROVIDED 95 CONSTRUCTION NOTES ALL RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED lO. REINFORCED CONCRETE SLAB FOR DUMPSTER REMOVAL AND DELIVERIES 2. EXISTING FLAT GRATE INLET TO BE REPLACED WITH CURB INLET, SEE GRADING PLAN FOR GRADING DETAIL CASTING TYPE. CORE DRILL NEW OPENING FOR 12" R.C.P. INTO EXISTING INLET SEE GRADING PLAN FOR INVERT DETAIL 0 SET NEW STRUCTURE OVER EXISTING 24" R.C.P., POUR BOTTOM IN PLACE GROUT BOTTOM TO MATCH FLOWLINE, SEE GRADING PLAN FOR GRADING DETAIL CASTING TYPE. 5O. CHAIRBACK CONCRETE CURB, SEE DETAIL SHEET FOR SPECIFICATIONS. 6O. POURED IN PLACE 6" VERTICAL CURB, SEE DETAIL SHEET FOR SPECIFICATIONS. 7O. SEE DETAIL SHEET FOR RAMP DETAIL 8O. PROPOSED TRANSFORMER LOCATION TO BE FIELD VERIFIED. ELEV. 891.03' UTILITY NOTE THE UTILITIES SHOWN ARE AS FOUND BY PHYSICAL ABOVE GROUND EVIDENCE AND UTILITY COMPANY RECORDS, THE EXACT LOCATION IS UNKNOWN, AND MUST BE VERIFIED PRIOR TO ANY CONSTRUCTION. BENCHMARK INFORMATION TEMPORARY BENCHMARK CAPPED REBAR STAMPED "ACE" AT SOUTHWEST CORNER OF PROPERTY. NOTICES AND PERMITS HOLEY VOLEY SEZ DO\'T DIG BLIND EXISTING STORM SEWER EXISTING SANITARY SEWER NEW STORM SEWER NEW SANITARY SEWER EXISTING CONTOURS PROPOSED GRADE PROPOSED GRADE 1 -800- 382 -5544 CALL TOLL FREE 1 -800- 428 -5200 FOR CALLS OUTSIDE OF INDIANA T.C. W G LEGEND 4. ALL STORM SEWERS TO BE PRIVATELY OWNED AND MAINTAINED. CAUTION PROPOSED PAVEMENT EXISTING PAVEMENT TOP OF CASTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF THE CONSTRUCTION AREA PRIOR TO STARTING ANY CONSTRUCTION. 3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY FOR NOTIFICATION AND COORDINATION OF ALL CONSTRUCTION WITH THE RESPECTIVE UTILITY COM— PANIES, PRIOR TO STARTING ANY CONSTRUCTION. WATER LINE OVERHEAD POWER GAS LINE UNDERGROUND TELEPHONE UNDERGROUND POWER GAS VALVE FIRE HYDRANT WATER SHUT —OFF VALVE AREA LIGHT PIPE BOLLARD HANDICAP SIGN PROPOSED ELEC. TRANSFORMER PROPOSED BLDG. DOWNSPOUT 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY AND STATE AGENCIES PRIOR TO STARTING CONSTRUCTION. LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. REVISION DATES DATE: 11/20/02 D "N TAT BY: CHECKED BY: SCALE: 1 30' FILE: NG 02 -428 JOB 02 -428 NO: SHEET NO. 3 C2 OF 8