HomeMy WebLinkAbout04100002 TAC Carmel Dad's Club, Concession Stand, Site Plan, pg 08STAND
x
C
BLLN
PIPE
<1
j IC
p �l
1
1
2,\
2,
WOODED AREA
CONCRETE
11E1889.25
STONE PARKING LOT
X
MAINTENANCE BUILDING
F.F.E.= 900.06
CONCRETE
L
1
r
i
11
cP
STON
STONE PARKING LOT
STONE PARKING LOT
a
R
STONE PARKING LOT
w
m
c r m
x
d
rn
CAP
03
CD
STONE PARKING LOT
3 r7 6 -1
L
CONCRETE
WATER VALVE
SPRINKLER
CONTROL BOX
1E1892.421
WATER VALVE
SANITARY CLEANOUT
SANITARY LATERAL
SANITARY LINE
SANITARY STRUCTURE NUMBER
SANITARY CASTING ELEVATION
EASEMENT LINE
SANITARY SEWER EASEMENT S.S.E.
SANITARY SEWER, DRAINAGE
UTILITY EASEMENT
STORM SEWER
CURB WITH SUBSURFACE DRAIN (SSD)
CURB INLETS
STORM SEWER INLETS
STORM MANHOLE
END SECTION
STORM SEWER STRUCTURE NUMBER
STORM SEWER INVERT ELEVATION
TOP OF CASTING ELEVATION
SWALE WITH SUBSURFACE DRAIN (SSD)
WATER METER
PROPOSED BLOW OFF ASSEMBLY
PROPOSED REDUCER
PROPOSED "TEE"
PROPOSED 45 ELBOW
WATER
WATER LINE
WATER VALVE
PROPOSED FIRE HYDRANT
PROPOSED 90' ELBOW
PROPOSED 22' ELBOW
PROPOSED 11' ELBOW
OVERHEAD ELECTRIC
BURIED ELECTRIC
ELECTRIC MANHOLE
POWER POLE
GUY WIRE
TRANSFORMER
ELECTRIC PEDESTAL
GUY POLE
ELECTRIC METER
STREET LIGHT
STREET UGHT
AREA UGHT
FLOOD LIGHT
OVERHEAD CABLE TELEVISION
BURIED CABLE TELEVISION
GAS LINE
OVERHEAD TELEPHONE LINE
BURIED TELEPHONE LINE
CABLE RISER PEDESTAL
GAS VALVE
GAS METER
UTILITY PLAN LEGEND
PROPOSED CONSTRUCTION
ELECTRIC
GAS CABLE TELEPHONE
KEY NOTE DESCRIPTION
'HOLEY COLEY SAYS CALL AT LEAST TWO FULL
WORKING DAYS BEFORE YOU DIG IT'S THE LAW
NEW LINE TO BE INSTALLED PER ELECTRIC COMPANY STANDARDS.
NEW CLEANOUT TO BE INSTALLED. SEE DETAIL SA -4.
NEW CLEANOUT TO BE INSTALLED. SEE DETAIL SA -1A.
1 -800- 382 -5544
CALL TOLL FREE
1 -800 -428 -5200
FOR CALLS OUTSIDE OF INDIANA
SANITARY SEWER
CO
as
L's
w
w
U ve
Vonii
ITC 1715.501
S.S.,D.& U.E.
11E: 715.501
ITC: 715.501
WA 0 0.70%
0
EM
fa/
CAUTION
w
E
BEC
.L
SANITARY MANHOLE
W
N
AA
E
BEC
CTV CTV
BCTV
G
BCTV
G
T T T
BTC BTC BTC
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUND EVIDENCE (including, but not limited to,
manholes, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE. THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND EVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
1
1
D
10/04/04
Project Number
040368 -10000
cO
rn
N
o
N.
0
N 1)
Q LL qL
OC 00 U
J N
5 co
N
v
N
q
Ef:
C
BY:
9
e
PE 10000126
STATE OF
7
Drawn afi
Checked
Quddy Mum=
Scoria
0 Scale: 1' a 30'
Shad
C501