HomeMy WebLinkAbout04100002 TAC Carmel Dad's Club, Concession Stand, Site Plan, pg 09w
w
GAS MARKER POST
2" W
w
8.5'x5.5' EUPTICAL CMP
1E= 892.28
CONC. WALK
w w
TC= 900.81 DID NOT LOCATE
END OF PIPE
IE=
0
0
0
0
0
0
a
0
0
0
0
0
IE= 894.68 8" CM
=1�
0
0
H
4.12 15" CMP
0
0
0
0
0
893.57
0
0
0
E- 897.17
t` G E.T
.'1 I
--CONC. WALK
DID NOT LOCATE
END OF PIPE
11E1885.97
a
co
0
J
0
126TH S REET
ASPHALT PA EMENT
DID NOT LOCATE
END OF PIPE
IE 42" RCP (E.)= 892.2'±
IE 42" RCP (S.W.)= 892.2'±
2.5' OF WATER IN MANHOLE__
DID NOT LOCATE
END OF PIPE
x 1
ca
m
TC= 896.37
1E 15" CMP (W.) =894.42 1 1
ao
-o rn
r- x
O
N o m rn I
a!)
co x
cs d
C1
PO
0
C)
m
1
1E1887.611
2" CMP
ASPHALT
w
BEC
TAND PIPE
xl
—o C
IE= 897.43
X
X
X
X
rn
m
m
c o
w
w
m
X
t
r
x
l
r co
2
x
F
TC= 900.85'
VALVE PIT
1E TOP OF PIPE= 894.39'
IE BOTTOM OF VAULT= 891.95'
TC= 900.79'
WET WELL
IE 10" PIPE (N.) =876'±
IE 8" PVC (S.)= 883.79'
1E 10" PIPE (W.)= 886.85'
STONE PARKING LOT
SANITARY CLEANOUT
SANITARY LATERAL
SANITARY LINE
SANITARY STRUCTURE NUMBER
SANITARY CASTING ELEVATION
EASEMENT LINE
SANITARY SEWER EASEMENT S.S.E.
SANITARY SEWER, DRAINAGE
UTILITY EASEMENT
STORM SEWER
CURB WITH SUBSURFACE DRAIN (SSD)
CURB INLETS
STORM SEWER INLETS
STORM MANHOLE
END SECTION
STORM SEWER STRUCTURE NUMBER
STORM SEWER INVERT ELEVATION
TOP OF CASTING ELEVATION
SWALE WITH SUBSURFACE DRAIN (SSD)
WATER
WATER LINE
WATER VALVE
PROPOSED FIRE HYDRANT
WATER METER
PROPOSED BLOW OFF ASSEMBLY
PROPOSED REDUCER
PROPOSED "TEE"
PROPOSED 45' ELBOW
PROPOSED 90' ELBOW
PROPOSED 22' ELBOW
PROPOSED 11' ELBOW
OVERHEAD ELECTRIC
BURIED ELECTRIC
ELECTRIC MANHOLE
POWER POLE
GUY WIRE
TRANSFORMER
ELECTRIC PEDESTAL
GUY POLE
ELECTRIC METER
STREET LIGHT
STREET UGHT
AREA LIGHT
BURIED CABLE TELEVISION
GAS LINE
OVERHEAD TELEPHONE LINE
BURIED TELEPHONE LINE
CABLE RISER PEDESTAL
UTILITY PLAN LEGEND
PROPOSED CONSTRUCTION
SANITARY SEWER
CO
GAS VALVE
GAS METER
ELECTRIC
KEY NOTE DESCRIPTION
'HOLEY HOLEY SAYS CALL AT LEAST TWO FULL
WORKING DAYS BEFORE YOU DIG IT'S THE LAW
1 -800- 382 -5544
CALL TOLL FREE
1- 800 -428 -5200
FOR CALLS OUTSIDE OF INDIANA
BA
I
ITC 1715.501
S.S.,D.& U.E.
500
IMOD
11E: 715.501
ITC: 715.501
SWALE 24D 0 0.70%
w
E
BEC
0
EM
FLOOD UGHT
GAS CABLE TELEPHONE
OVERHEAD CABLE TELEVISION CTV
BCTV
G
SANITARY MANHOLE
E
BEC
CTV
BCTV
G
T T T
BTC BTC BTC
0
NEW LINE TO BE INSTALLED PER ELECTRIC COMPANY STANDARDS.
NEW CLEANOUT TO BE INSTALLED. SEE DETAIL SA -4.
NEW CLEANOUT TO BE INSTALLED. SEE DETAIL SA -1A.
NEW WATER METER TO BE INSTALLED.
CONNECT TO EXISTING 12" WATER MAIN
CONNECT TO EXISTING 8" PVC FL 883.79'
CAUTION
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUND EVIDENCE (including, but not limited to,
manholes, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE. THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND EVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
1
J
0
0
0
CC
w
0
Z
0
0
J
0
J
w
CC
U
w
oC
U
U
cn
w
W
5 z
U
5
W
N Z
o
w <Z>.
F-
va
07 rn
5 zzzzz
o PE 10000126 n
STATE OF
i4
s; 5
'J /j J 0 1 `4 AL
Drown Syr.
Checked By:
Quality Assurance
soap
Scale 1'
OMNI
MIME N�
Sheet
C502
Date
10/04/04
Project Number
040368 -10000
1