Loading...
HomeMy WebLinkAbout04070233 Site PlanTRENCH EXISTING GRADE ELEVATIONS AND TRENCH DEPTHS ALONG PROPOSED TRENCHES PROPOSED TRENCH BOTTOM ELEVATION INLET MIDDLE END 1 99.5 12" 99.8 16" 99.8 16" 98.5 2 99.5 10" 99.9 14" 100.0 16" 98.7 3 99.6 10" 100.1 16" 100.1 16" 98.8 4 99.6 10" 100.1 16" 100.1 16" 98.8 5 99.6 10" 100.1 16" 100.0 14" 98.8 6 99.6 1 1 100.0 16" 99.9 14" 98.7 7 99.5 1 1 99.9 16" 99.9 16' 98.6 8 99.5 1 1 99.8 14" 99.9 16" 98.6 9 99.4 11' 99.6 13" 99.8 16" 98.5 IJ Cc CC C=D cD PERIMETER DRAIN OUTLET WITH ANIMAL GUARD NOTE: INV 95.5 THE EXISTING POND IS LOCATED WITHIN COMMON AREA "D" OF WESTWOOD ESTATES SECTION 1, THE PLAT OF WHICH IS RECORDED AS INSTRUMENT #200300124222, PC 3, SLIDE 313, IN THE OFFICE OF THE RECORDER OF HAMILTON COUNTY, INDIANA. PERMISSION TO CROSS SAID COMMON AREA "D" TO BE OBTAINED BY OTHERS. 15' 0 v LI E. 0;1 C 0l Li v C 0) X w Ex Board Fence 1 1 1I 93 254,7' SOIL BORING 1- 800- 382 -5544 HOLEY MOLEY SAYS "DIG SAFELY" "IT'S THE LAW" Q 9 9 1 4" ASTM -D 2729 PERFORATED LATERALS 1 (TYPICAL) 1 INV =96.0 1 CALL 2 WORKING DAYS BEFORE YOU DIG CALL TOLL FREE PER INDIANA STATE LAW IC8 -1 -26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. EXISTING COMMON AREA "D" OF WESTWOOD ESTATES SECTION 1 -SOIL BORING ,fi 1 'o '11 N9OOOOOOi 46 \INV =96.5 EXISTING EDGE OF WATER SURFACE ELEVATION 95.0± INV =96 -3 r 7 4" ASTM -D 2241 SDR -21 SOLID PVC (TYPICAL) DISTRIBUTION BOX INLET INV- 99.6 INV= 103..1 INV -103.3 4" ASTM -D 3034 SDR -35 SOLID PVC`s 1500 GALLON SEPTIC TANI< r�1 106.5 z 12" EARTH EXISTING GRADE EXISTING POND 10" MIN. 16" MAX. P INV =104.0 r 0 MIN. BACKFILL SCALE: ----1. �1 20 40 r1250 GALL,11 DOSING TANK AST!,1 -D 3034 INV=103.4 SDR -35 SOLID PVC i !NV�103.8 D106.5 „,.u 1106.51 SYNTHS I IC FILTER FABRIC 7} INVERT E.-.EVA, 3 5 „p i•..i PROPOSED EL EXISTING CON, [OUP PT 6.51 �IBIBIr =Y,. I�kL�IE -IIE� &I -IEIBI IL BI81B16 BIt_ 3IEIIE11E11 IB, p IP IRI II- s90 %15.34 8 r, 92.6' 2" MIN_ GRAVEL COVER ON TOP OF PVC PIPE 4" PERFORATED PVC PIPE .5 -2.5" DIAMETER WASHED �T GRAVEL Lip LC) CD CC I I I C'Nl CC LC 0 CD FINISH GRADE fi rLIYFL% �;ii_ 36" 1 ABSORPTION TRENCH DETAIL (NO SCALE) TREE LINE S90°00'00''VV 250.52' 1 (8.855 Ac.±) CENTERLINE 05 3: Y AND E r<L55 EASEMENT FOR THE USE OF LOT NUMBER ONE AND LOT NUMBER PR aPOSaa E �I PERIMETER DRAIN TO BE 24" BELOW TRENCH BOI ELEVATION OF NEAREST ABSORPTION TRENCH T# N 1724'09"E 36.71' 1A I EiI 7 H f �1 EXISTING RAVEL DRIVE (SEE NOTE 12) 4" MINIMUM PERFORATED DRAIN WIPE 4 H (NO SCALE) SUBSURFACE DRAIN DETAIL "A -A" 5 E-- Lil LU 15 LU FINISH GRADE 12" TOPSOIL 30 25 20 10 9.4` 5 0 15' D. SYNTHLI IC FILTER FABRIC 1/3 HP MAX. SOLIDS 1/2" SPHERE 1550 RPM 7 tip AMPS AT 16 115 V. 0 5 10 15 20 25 30 35 i 43 45 38.3 40.5 U.S. GALLONS PER MINUTE (765.6 gallons per 20 minutes with a total head of 9.4') PUMP DISCHARGE CURVE HYDROMA TIC VS33 LAND DESCRIPTION: Lot No. 1 in BENNETT SUBDIVISION, a subdivision in Hamilton County, Indiana, as per plat thereof, pending final recording, in the office of the Recorder of Hamilton County, Indiana. FLOOD NOTE: Based on a scaled interpretation of FLOOD INSURANCE RATE MAP COMMUNITY PANEL NUMBER 18057CO205F, effective February 19, 2003, the within described real estate DOES NOT LIE within a Special Flood Hazard Area Zone A, as established by the Federal Emergency Management Agency for the National Flood Insurance Program. NOTE: Elevations shown are based upon an assumed elevation of 100' and are. not U.S.G.S. elevations. INFLOW FROM DOSING TANK 6" min. 1 .5" min DISTRIBUTION BOX DETAIL 4 (NO SCALE) OUTFLOW TO ELBOW TO FIELD BAFFLE FLOW >C'1 ReLEASEO FOR CONSTR Subject to compliance with all OT�I or State end Loc l! C �ecul�lHo DEPT OF CO ,ode; CITY OF IFlYDVW: C.A :I 1 :,_1 EARTH BACKFILL 4" MINIMUM SOLID DRAIN PIPE 4 H SUBSURFACE DRAIN DETAIL "B -B" (NO SCALE) (NO SCALE) I IEi I �,:�ICl I11I 50 8" min. 4" min. 1.5" min. INLET INV =103.8 REINFORCED CONCRETE ALARM 103.0 ON 102.5 765.6 GALLONS OFF 99.6 SECURE GAS TIGHT COVER--- IEVENI �J'EIF INSPECTION PLUG DISCONNECT POWER CONDUIT INV =103.3 FROM SEPTIC TANK AESaII MIN. 'I EDE TAL MIN. -12" MANHOLE .15 LIQUID LEVEL LIQUID DEPTH "D" 30" TO 78" HIGH WATER ALARM LIGHT AND HORN MIN GAS DEFLECTION BAFFLE FRICTION LOSS ELEVATION HEAD TOTAL DYNAMIC HEAD 1500 GALLON SEPTIC TANK DETAIL THE EFFLUENT PUMP IS TO BE WIRED ON A SEPARATE CIRCUIT THAN THE AUDIO /VISUAL ALARM HYDROMATIC VS33 PUMP PUMP CAPACITY 40.5 G.P.M. I 3 f LIFTING CHAIN GUIDE RAILS `NO CHECK VALVE BREAK AWAY FLANGES f INV =103.1 TO FIELD CARMEL CONCRETE, 1250 GALLON DOSING TANK STORAGE VOLUME 22 GALLONS PER JERTICAL INCH 1250 GALLON DOSING TANK DETAIL (NO SCALE) FINISHED GRADE (NO SCALE 2" 9.4 FEET 0.0 FEET 9.4 FEET MIN. OUTLET INV =103.4 4" TO 6" ACCESS HATCH TO BE LARGE ENOUGH FOR PUMP REMOVAL AND MAINTENANCE 102' OF 1.5" PVC SDR 21 SEWAGE DISPOSAL SYSTEM SPECIFICATIONS 1. Required absorption field system: a. 3' wide trench (see cross section) b. 8' minimum spacing center of trench to center of trench c. 834 lineal feet absorption trenches minimum 2. 1-1500 gallon septic tank minimum with access riser and double lid 3. Piping specifications a. 10' of 4" ASTM -D 3034 SDR -35 solid plastic line from house to septic tank b. 4' of 4" ASTM -D 3034 SDP -35 solid plastic line from septic tank to dosing tank c. 102' of 1.5" ASTM -D 2241 SDR -21 solid PVC from dosing tank to distribution box d. 4" ASTM -D 2241 SDR -21 solid PVC from distribution box to trenches e. 837' of 4" ASTM -D 2729 perforated laterals 9 LATERALS 93' EACH f. All Hamilton County and State of Indiana Standards to apply GENERAL NOTES 1. There shall be a mandatory pre construction meeting with the Hamilton County Health department prior construction of any part of the septic system. 2. Construction of septic system will commence when soils are dry. 3. System wcs designed and shown with the intention of the laterals being installed at minimum depths and therefore more permeable soils. 4. No clay fill materials will be placed over absorption field. 5. Absorption field shat' be finish graded to obtain positive surface drainage away from the field. Any finish grading done in area of absorption field will be done with light equipment. 6. No compaction from construction traffic to be allowed in absorption field area. It is suggested the area be isolated by fencing or other means. Existing elevations sown should be verified before construction begins. Design shown is based on elevations shown. Septic system design NOS based upon Hamilton County Board of Health recommendations. 9. Following installation ald prior to back filling of septic system trenches, Hamilton County Board of Heal shall be notified for inspection. 10 Surfaces, connections, and accesses to all tanks are to be sealed watertight to prevent water leakage into system. 11 All absorption lateral trench bottoms shc.i be level along their length. 12. The perimeter drain tench surrounding the absorption field shall be backfilled a minimum of 12" with "L" co arse gravel, and to a point no more than six inches from the ground surface. a. C- ,U Q DC c Z L4 J DC C? L$ 1-4 SHEET NO. PROJECT NO. C- C- L I \`i ��1111 111 11I/// Y.. C y, Q Q' O PE19500338 5 STATE OF /III1111111��� PATRICK C. SHEEHAN PE19500 W04 -0079 U C w CO 0 C