HomeMy WebLinkAbout04100007-15 KFC, Long John Silvers, Site Plan, pg 08F, OF 2" RCP 00.71%
KL60 Y04 JAN04 -E 4 L,F.OF 4
F.F. 841.75 Ca on
INV. 837.75
C.O.
NV.•837.00
UE
UTILITY CROSSING
INV. 12" STORM 836.35
INV. 6" SAN 835.35
107 L.F. OF 8" PVC 0 2.33*
n
W
11
11
11
11
11
11
11
EX. 2" rCP ST-
0.4'± 10.4'± 10.4'± 10.4'± 10.4'±
0
O
0
r
1
T
01'
a
0
tf)
W
EX
V)
a
0
N89'55'00 "E 204.99'
EXISTING STORM SEWER INLET
RIM 842.65
INV. 12" RCP (E)= 837.55
EXISTING STORM SEWER CURB INLET
RIM 842.73
INV. 12" RCP (W)= 838.49
EXISTING STORM SEWER MANHOLE
RIM 840.25
INV. 36" RCP (N)= 832.26
INV. 36" RCP (S)= 832.26
PROP. INV. 12 (E) =834.26
EXISTING STORM SEWER INLET
RIM 837.04
INV. 12" (NE) =N/A
INV. 18" (E)= 823.04
INV. 24" (S)= 823.09
EXISTING STORM SEWER INLET
RIM 836.84
INV. 24" (N)= 823.14
EXISTING SANITARY SEWER MANHOLE
RIM 832.96
INV. 8" VCP (N)= 820.26
EXISTING SANITARY SEWER MANHOLE
(APPROX. 199.0' NORTH OF PROPERTY)
RIM 843.08
INV. 8" VCP (S)= 829.38
ASPHALT".?"
777777771
EX. CONCRET
777777111
lllllll/% /7277777i/// ///777777777 /7
EX. BUILDING
DAY FURS
ASPHALT
PROPOSED CATCH BASIN
RIM 839.69
INV. 12" HDPE 0) =834.70
INV. 12" HDPE (E)= 834.70
INV. 6" PVC (N) =835.20
PROPOSED CATCH BASIN
RIM= 839.47
INV. 12* HDPE (W)= 835.24
INV. 12* HDPE (NE)= 835.24
PROPOSED CATCH BASIN
RIM 839.83
INV. 12" HDPE (SW)= 835.91
INV. 12" HDPE (N) =835.91
PROPOSED CATCH BASIN
RIM 840.00
INV. 12* HDPE (W)= 836.75
INV. 12" HDPE (S)= 836.75
INV. 8" PVC (SW) =837.08
PROPOSED CATCH BASIN
RIM =840.83
INV. 12" HDPE (E) =837.66
INV. 6" PVC (S)= 838.16
PROPOSED YARD DRAIN
RIM =840.66
INV. 8" PVC (NE) =837.99
-STRIP MALL
EX. BUILDING
Viz lllllll111 1111 Liz 11111111111111 .!!11111111.1
S89'55'00 "W
204.99'
PROPOSED 1,000 GALLON GREASE INTERCEPTOR
INLET:
RIM= 841.75
INV. 4" C.I. (W) =837.67
OUTLET:
RIM= 841.75
INV. 4" PVC (E)= 837.42
1
1 -T- UE
EX. WALL
Eg�
NV. ••824.4r
I PROP, SANITARY RISER.
SEE:`DETAIL 8, SHEET
C4.1, AND SANITARY
NOTES 5
SHEET.
EX. CONCRETE
J
can
a
F L,J
Z
W
D
w Q
EX. 30.0' UTILITY
EASEMENT
EX. BUILDING
c.
-PROP. R/W-
E/T BANK
4
I
i
R
-EX. ST
SS
0
dt UT
D.S. O
C.O.
0 20
FIRE6ips="9
10 40
HORIZONTAL
SCALE IN FEET
LEGEND
-EX. SAN
EX. W
-EX. GAS--
PROPERTY MARKER
CENTERUNE
PROPERTY UNE
PROPOSED RIGHT -OF -WAY DEDICATED
TO THE CITY OF CARMEL (45.01')
EXISTING DIRECTION OF TRAFFIC
EXISTING CURB TO REMAIN
EXISTING TOP BANK OF DITCH
EXISTING BOLLARD
EXISTING SIGN
EXISTING TREE
EXISTING U11UTY POLE
EXISTING UGHT POLE
EXISTING ELECTRICAL TRANSFORMER
EXISTING A/C UNIT
EXISTING STORM SEWER MANHOLE
EXISTING STORM SEWER INLET
EXISTING HYDRANT
EXISTING WATER METER
EXISTING WATER VALVE
EXISTING TELEPHONE MANHOLE
BENCHMARK LOCATION
PROPOSED CURB
PROPOSED UGHT POLE
PROPOSED CATCH BASIN
PROPOSED YARD DRAIN
PROPOSED EXTERIOR
GREASE INTERCEPTOR
PROPOSED SIGN
PROPOSED CONCRETE
EXISTING STORM SEWER
EXISTING SANITARY SEWER
EXISTING WATER SERVICE
EXISTING GAS SERVICE
PROPOSED WATER SERVICE
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED GAS SERVICE
PROPOSED UNDERGROUND ELECTRIC
TELEPHONE SERVICE
PROPOSED DOWNSPOUT
PROPOSED CLEAN OUT
APPURTENANCES
PROPOSED ELECTRICAL CONDUIT
(SEE ELECTRICAL SHEETS)
EASEMENT UMITS
BENCHMARKS;
BENCHMARK #2: SOUTH BONNET BOLT ON HYDRANT
ELEVATION an 740.53
GENERAL UTILITY NOTES
1. THE LOCATIONS OF UNDERGROUND FACIUTIES SHOWN ON THE PLAN ARE BASED ON FIELD SURVEYS AND LOCAL U11UTY COMPANY
RECORDS. IT SHALL BE THE CONTRACTORS FULL RESPONSIBIUTY TO CONTACT THE VARIOUS UTIUTY COMPANIES TO LOCATE THEIR
FACIU11ES PRIOR TO STARTING CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR DAMAGE
AND REPAIR TO THESE FACIUTIES CAUSED BY HIS WORK FORCE.
2. SEE SHEET C4.1 FOR U11UTY DETAILS.
WATER NOTES
1 WATER SERVICE MATERIALS SHALL BE COPPER TYPE "K" UNLESS OTHERWISE NOTED ON PLANS. DIAMETER SHALL BE NOTED ON
THESE PLANS AND SHALL BE INSTALLED WITH A MINIMUM COVER OF 42" OR BELOW FROSTUNE, WHICHEVER IS GREATER.
2. THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL TRENCHING, BACKFIWNG, PIPE, AND INSTALLATION OF THE WATER SERVICE UNE
FROM THE EXISTING LATERAL TO THE BUILDING. CITY OF CARMEL SHALL INSTALL INSTALL WATER METER. THE CONTRACTOR'S
PRICE FOR WATER SERVICE SHALL INCLUDE ALL FEES AND APPURTENANCES REQUIRED BY CITY OF CARMEL TO PROVIDE A
COMPLETE WORKING SERVICE. COORDINATE ALL SERVICE WORK WITH CITY OF CARMEL, DICK HILL 0 317- 571 -2459.
3. CONTRACTOR SHALL PROVIDE 100% IRRIGATION PER CONSTRUCTION MANAGER AND CITY REQUIREMENTS.
ELECTRICAL NOTES
1. SEE SHEET E1.0 FOR SITE UGHTING AND LUMINAIRE DESCRIPTION.
2. SEE ELECTRICAL SHEETS FOR ALL DEDICATED EXTERIOR BUILDING AND SIGN UGHTING SCHEDULES. ELECTRICAL CONTRACTOR SHALL
BALANCE LOADS WHERE REQUIRED.
3. ALL DIRECTIONAL SIGNAGE WIRING SHALL BE NO. 12 AWG IN 3/4" PVC DUCT. ALL PARKING LOT UGHTING WIRING SHALL BE NO.
10 AWG IN 3/4" PVC DUCT.
4. CONTRACTOR SHALL FURNISH AND INSTALL 2 -4" PVC SCHD. 40 DUCTS, INCLUDING ALL TRENCHING, BACKFIWNG, AND
SECONDARY WIRE, FROM BUILDING TO TRANSFORMER. CINERGY SHALL MAKE APPROPRIATE PRIMARY AND SECONDARY CONNECTIONS
AT TRANSFORMER. CONTRACTOR SHALL INCLUDE ALL FEES REQUIRED BY CINERGY TO PROVIDE A COMPLETE WORKING SERVICE.
CONTRACTOR SHALL COORDINATE ALL ELECTRICAL REQUIREMENTS, INCLUDING THE EXACT LOCATION OF ELECTRIC SERVICE WITH
CINERGY, DEAN GROVE 0 317 581 -3041.
SANITARY SEWER NOTES
1. SANITARY SEWER LATERAL INVERT AT BUILDING SHALL BE A MINIMUM OF 4.00' BELOW FINISH FLOOR.
2. THE CONTRACTOR SHALL BE UCENSED BY THE CITY OF CARMEL AND WILL BE RESPONSIBLE FOR MAKING ALL CONNECTIONS TO
EXISTING SANITARY SEWER, THE CONTRACTOR SHALL EXTEND SANITARY UNE INCLUDING ALL TRENCHING, BACKFIWNG, PIPE,
FITTINGS, RISERS, MANHOLES, AND INSTALLATION FROM BUILDING TO THE EXISTING SANITARY SEWER. CONTRACTOR SHALL SECURE
A SANITARY SEWER CONNECTION PERMIT PRIOR TO ANY CONSTRUCTION. THE CONTRACTORS PRICE FOR SANITARY SEWER
INSTALLATION SHALL INCLUDE ALL FEES AND APPURTENANCES REQUIRED BY THE CITY OF CARMEL TO PROVIDE A COMPLETE
WORKING SERVICE. COORDINATE ALL WORK WITH THE CITY OF CARMEL, JIM HAGGE 0 317- 733 -2001.
3. ALL SANITARY PIPE MATERIAL SHALL BE PVC CONFORMING TO ASTM D 3034, TYPE PSM FOR SIZES 6" -15 THE MINIMUM SDR
SHALL BE 26. THE PIPE AND FITTINGS SHALL BE MADE FROM PVC PLASTIC HAVING A MINIMUM CELL CLASSIFICATION OF 12454 -C,
AND SHALL HAVE A MINIMUM PIPE STIFFNESS OF 46 PSI. MINIMUM SANITARY LATERAL PIPE SIZE PERMITTED IS 6 THE PIPE
FROM BUILDING TO GREASE TRAP SHALL BE CAST IRON (C.L).
4. CLEAN -OUTS TO BE INSTALLED AT ALL PIPE BENDS AND ANGLES, UNLESS A MANHOLE IS INDICATED.
5. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION, INVERT ELEVATION, AND CONDITION OF EXISTING SANITARY SEWER AND LATERAL
PRIOR TO ANY CONSTRUCTION. CONTRACTOR TO ENSURE EXISTING SEWER IS IN GOOD CONDITION AND FREE FLOWING. IF
ELEVATIONS DIFFER FROM WHAT IS SHOWN ON THIS DRAWING, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY.
6. CONTRACTOR SHALL REUSE EXISTING LATERAL IF IT IS IN GOOD CONDITION.
NATURAL GAS NOTES
1. VECTRUM SHALL OBTAIN NECESSARY PERMITS, MAKE CONNECTION TO EXISTING LATERAL AND FURNISH AND INSTALL SERVICE UNE
FROM THE EXISTING GAS LATERAL TO THE BUILDING, INCLUDING ALL TRENCHING AND BACKFIWNG. VECTRUM SHALL FURNISH AND
INSTALL METER. CONTRACTOR SHALL VERIFY CONNECTION TO EXISTING GAS SERVICE WITH GAS COMPANY PRIOR TO INSTALLATION.
CONTRACTOR SHALL INCLUDE ALL FEES REQUIRED BY VECTRUM TO PROVIDE A COMPLETE WORKING SERVICE. COORDINATE ALL
WORK WITH VECTRUM, DAVE CATRON 0 317- 736 -2925.
2. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF EXISTING GAS MAIN. IF LOCATION DIFFERS FROM WHAT IS SHOWN ON THIS
DRAWING, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY.
TELEPHONE NOTES
1. THE CONTRACTOR SHALL PROVIDE AND INSTALL A 2" PVC SCH. 40 DUCT WITH PULLWIRE FROM THE BUILDING TO THE EXISTING
UTILITY POLE INCLUDING ALL TRENCHING, BACKFIWNG, AND CONDUIT. SBC SHALL FURNISH, INSTALL, AND MAKE CONNECTION OF
WIRE AND WIRING. SBC SHALL VERIFY EXACT LOCATION OF EXISTING SERVICE. COORDINATE SERVICE WITH SBC, DAVID MUSALL 0
317- 252 -5143.
2. CONTRACTOR SHALL COORDINATE THE NUMBER OF UNES REQUIRED WITH THE CONSTRUCTION MANAGER.
STORM SEWER NOTES
1. ALL STORM SEWER PIPE SHALL BE CONSTRUCTED USING THE MATERIALS USTED ON THE PLAN. HIGH DENSITY POLYETHYLENE
(HDPE) SMOOTH INTERIOR PIPE SHALL CONFORM TO ASTM D 3350. REINFORCED CONCRETE PIPE (RCP) SHALL CONFORM TO ASTM
DESIGNATION C -76, CLASS -III, WALL-B WITH 0 -RING JOINTS. DOWNSPOUTS SHALL BE POLYVINYL CHLORIDE (PVC) PIPE
CONFORMING TO ASTM D 3034 TYPE PSM OR ASTM D 303 TYPE PSP. THE MINIMUM SDR SHALL BE 35. CONTRACTOR MAY
SUPPLEMENT HDPE WITH PVC ONLY (SIZE NOTED ON PLANS).
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRENCHING, BACKFIWNG, AND PIPE INSTALLATION. COORDINATE ALL WORK
WITH THE CITY OF CARMEL ENGINEERING DEPARTMENT, GARY DUNCAN 0 317- 571 -2436.
3. ALL CATCH BASINS SHALL BE CONSTRUCTED AS SHOWN ON THESE DRAWINGS AND DETAILED ON SHEET C4.1 OR PER THE CITY
SPECIFICATIONS, WHICHEVER IS MORE STRINGENT.
4. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION, INVERT ELEVATION, AND CONDITION OF EXISTING STORM SEWER PRIOR TO ANY
CONSTRUCTION. CONTRACTOR TO ENSURE EXISTING SEWER IS IN GOOD CONDITION AND FREE FLOWING. IF ELEVATIONS DIFFER FROM
WHAT IS SHOWN ON THIS DRAWING, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY.
5. CONTRACTOR SHALL CORE DRILL AND SEAL EXISTING CATCH BASIN TO MAKE CONNECTION, ENSURING A 'TIGHT FITTING CONNECTION.
CONTRACTOR SHALL MAKE AU. CONNECTIONS TO EXISTING CATCH BASIN PER CITY OF CARMEL SPECIFICATIONS, AND ENSURE
CONNECTION DOES NOT LEAK.
"DON'T Y
DIG
BLIND
Cali Monday thru Friday 7 am. to 6 pm.
1-800-382-5544
TOLL FREE
1-800-428-5200
OUTSIDE INDIANA
NOT /CE TO CONTRACTOR
PER INDIANA STATE LAW 1S -69 -1991, IT IS
AGAINST THE LAW TO EXCAVATE WITHOUT
NOT/fY!NG 7HE UNDERGROUND LOCA77ON SERV/CE
TWO (2) WORKING DAYS BEFORE COMMENCING WORK.
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
PLOT DATE:
U til
W W
o
ii N r
0 N N
S te
t, m
:.',1 w r 2
c
0 .(1).1 6.8
N
Q
J
E gi M
0
U
KFC LJS
KL6O-y04
UTI LITY
PLAN
C4.0
0
3
nt
O ro
n�t
w c e�-
M
03
C c N ch
M
n
XX.XX.XX
KL60 -y04
Jan04 -E
283006
2004087.05
1331 S. RANGELINE ROAD
CARMEL, IN 46032
L NC])o IkN
08.27.04