Loading...
HomeMy WebLinkAboutPacket 12-15-09LONG BRANCH MARKET Docket No. 09100009 DP /ADLS DEVELOPMENT PLAN AND ADLS CITY OF CARMEL, INDIANA December 15, 2009 Carmel Plan Commission Applicant: Kroger Food Stores Attorneys Nelson Frankenberger, P.C. Attn: Charles D. Frankenberger, Attorney 844 -0106 Attn: Jon C. Dobosiewicz Professional Land Planner 844 -0106 TABLE OF CONTENTS 1. Explanation of Request 2. Site Location Exhibits 3. Colored Site /Landscape Plan 4. Kroger Building Perspective and Elevations 5. B -shops Building Perspective and Elevations 6. Fuel Station Building Elevations 7. Building Facade and Building Base Landscaping Exhibit 8. Landscape Plan and Detail Sheets 9. Landscape Buffer and Screening Detail Exhibits 10. Signage Plans 11. Site Lighting Plan with Fixture Details 12. Site and Building Detail Exhibits 13. Engineered Plans 14. Existing Commitments 15. Proposed Commitments Kroger Booklet TOC PC 112609 TAB 1 EXPLANATION OF REQUEST Kroger Food Stores is desirous of constructing a grocery store and fuel station, along with additional smaller shops and two outlots, on approximately 22 acres of real estate located on the east side of Michigan Road between 106"' Street on the south and 116"' Street on the north. The site is just south of the Aaron Ruben Nelson Mortuary and is currently occupied by the Altum's Landscape Nursery business. The site is outlined on the aerial photograph included under Tab 2. It is zoned B -3 Business District and is also within the US 421/Michigan Road Overlay Zone. In order to allow this redevelopment, two approvals have been requested; namely, (i) approval of the development plan and architecture, design, lighting, landscaping, and signage (DP /ADLS) from the Plan Commission and (ii) approvals of developmental standards variances from the Board of Zoning Appeals. To this end, we will present the request for DP /ADLS to Plan Commission on December 15, 2009, and we will present the requests for development standards to the BZA on January 6, 2010. Approximately twenty years ago, the subject site was rezoned to the B -3 Business District. At that time, before the character of the area had become significantly more commercial, written commitments were extended. A copy of these existing commitments is included under Tab 14. As indicated, the existing commitment allows twelve (12) specific permitted B -3 uses, and also prohibits other permitted B -3 uses unless allowed by the Plan Commission. The proposed grocery store and other retail uses are permitted uses within the B -3 District, but are not among the twelve (12) B -3 uses specified in the existing commitment. Consequently, we are also asking the Plan Commission, per the terms of the existing commitment, to allow our proposed, B -3 uses. In this regard, and to further clarify the uses allowed upon the site, we are proposing the replacement commitment included under Tab 15. The request for DP /ADLS approval is fully detailed in this submittal. Included are (i) an aerial photograph with an overlay of the site plan, (ii) a colored rendering of the site landscape plan, (iii) colored building elevations, perspectives and building material information, (iv) landscape buffering and screening details, (v) renderings of the signs, (vi) a photometric lighting plan and cut sheets of the proposed fixtures, (vii) proposed development commitments and (viii) reduced -size development plans. The applicant has worked diligently with surrounding property owners and, as indicated under TAB 3 and TAB 9, great care has been taken to provide meaningful buffering between the subject property and surrounding residential areas. All traffic and activity to the side and rear of the anchor tenant and b -shops will be completely screened, far beyond the buffering requirements of the Zoning Ordinance. Both existing mounds and landscaping along the north property line, as well as a new 8' tall mound along the east and south property lines, will be augmented with a new 8' fence to provide an immediate and solid visual barrier. We look forward to presenting this request on December 15, 2009. Respectfully submitted, Charles D. Frankenberger Jon C Dobosiewicz H:\Beeky\Zoning Real Estate Matters\Zinkan Barker \Cannel- MiehiganRd\Infonnation Booklet\Plan Commission 121509 \Word Does\Kroger EXPLANATION PC 112709 doe TAB 2 r J tl w r :t VE Cw X 57: wz m, l Proj. No.: 2009 -0817 SCALE: SI TE LOCATION ON= N.T.S. AERIAL EXHIBIT D KROGER J904 Evans. Mechwori, Wombleton 8 rRon, Inc. October 16, 2009 Eng�naers Surveyors Planners Scientists 7400 N. 11335 N. MICHIGAN ROAD Phor: 317.13.930 Sla.I k ree: 0 .715. 6 48 SHE ET No. Phone: 317.913.6930 Toll kee: 888.775.3648 A2 emkcom k A A)t k 'IV L. .0f F ow Wal-Mart a r Rea I 6 7 '0.- LA F �ss An e' s s F m 1. v 1 m a 9'1 P J I 1 i i i n o t mo r o m m z A r O z s N C j C N s I f t 1 z �p T a O 0 1 o rn m Y 0 0�071 9 pN °T° m0 >1 z °D 0 4 ljJ z w w zzz z H 1 m 0m mI n o0 CID z ML N O O l� n Q C 1 F z a O m �m0 z D z SITE LOCATION AERIAL EXHIBIT KROGER J904 11335 N. MICHIGAN ROAD yp �C 4 Evans, Mechwart, Hambleton Tilton, Inc. Engineers Surveyors Planners Scientists o 7400 N. Shadeland Ave., Ste, 150, Indlanapofis, IN 46250 Phone: 317.913.6930 Toll Free: 888.775.3648 0 emht.com C m Aft O zi O z TAB 3 �7 0 wzz 0 i Y 77 ICI CS R ol RE IF y -t 7- Ca x(3 NS ROAD M4 cl Me TAB 4 C N J U T Q T V/ L N L Y Z M r O C f6 U m C-10 C N J U U) L Z O Q L1J J w H Z O LL O Z O Q LU LL J W W 0 m T T V/ L N 0 L Y w O O (6 U D TAB 5 C N J U Z m 0 rn (0 L U N L Y 3 v v V a) W O CL O N v CL N U N 3 E s m U O c O m �w� �I MEMO •.Jii�ii ii- ii 1�i Ali■ FRONT ELEVATION WEST All tenant signage to be 3 foot tall (max.), individual channel letters (no raceways), black and white with three additional colors maximum. 130-I TlMA9ONRY 12T$ i er retail center November 25, 2009 MC-01 E-1 CS-01 Ca-01 MD -01 PT U& SOLDIER COURSE, CB U1 Y REAR ELEVATION EAST 124' -a' fMA50NRY 1W-W TIMASONRY i o0-0' FIN. FLOOR Kroger Cp Carmel, IN hk 509031 architecture d e s i g n SIDE ELEVATION NORTH TAB 6 M-H.ln 0 2 0 2 0 LL 7 E 0 W c _0 7 E 0 W _0 m 0 mom 2 7 Y 3 cc cli M O M k ZW C:T- 2 TAB 7 m O s NF O 0') L (D 0) 0 L Y Z M r O C f6 U D •hip nob aio)eq Ilg� 'M00 sleym mouN 1 q ZSlB'6LS'L6E :xj £918611'11£. :4d OSZ9t NI syOdeuelpul nuQ }saM,(emallse0 6965 bNVIONI '"13W?Jtl0 avoa NVOiNOiw'N Seeu N31N3'J 1IV13M voer a39oam aoa SN— NO 10n-SNOO N,,, o Z o ny'"ub PR m ntaory o enia s33ai3avns xo 1 a 9� 3fanea 3au io maze J� IN w�� O Nob a c a s' b J( o \\A\ ax e� \'1 O F c��N +a 550UF NSP` /z .�q ORN 50E ER x 3 I w Z J H I N U44Y�. x x x u a i xauvs 30 Sin amz 6i nod awo p )s,wgmma mo�aq le4 N1 zs I8 6L9 LIE :x= EM? 6L9 LIE :4d OSZ9b NI s.Iodeuepul a ..d..o .B lae� R 0q uedwo� I ayl VNVION113INUVO Ntl�JIH� N �131N3�'11tl13Z1 406P m3'J0m2i sNVIa NouanaisNOO may .a3�a" a a a a m I I b O In m 0 XX of J o \V, 'III N m q-p^ d r o Ix I p w J p¢ Z _j W1 cc Z m w -mojoqswqmmou)I 0 Z:9[8 US LlC:X=I C9 96L2 I LE :qd 95Z9b I s ilodeuepul A­d GVO� N�IHCIN *N M I I H31N33 lIV13H IP06f U300mm S­dNOixomISN00 E 2 E z C4 N wa. 0 O Z _j W1 cc Z m w z :52 N wa. 0 O T K MH p 29 M M -M, t i H M Hd mss 'IM g., -N H Z _j W1 cc Z m w z :52 Z W1 wa. O TAB 9 Proj. No.: 2009 -0817 KALE: N.T.S. )ate: Octobe 2 6, 2 009 HEET No. S3 EVERGREEN SCREENING EXHIBIT KROGER J904 11335 N. MICHIGAN ROAD Evans, Mechwart, Hambleton Tilton, Inc. Engineers Surveyors Planners Scientists 7 400 N_ Sit a del and Ave., Ste. 150, Indianapolis, IN 46250 Phone: 317.9 13.6930 Toll Free: 885.775.3648 Proj. No.: 2009 -0817 KALE: N.T.S. )ate: Octobe 2 6, 2 009 HEET No. S1 EVERGREEN SCREENING EXHIBIT KROGER J904 11335 N. MICHIGAN ROAD Evans, Mechwart, Hambleton Tilton, Inc. Engineers Surveyors Planners Scientists 7 400 N_ Sit a del and Ave., Ste. 150, Indianapolis, IN 46250 Phone: 317.9 13.6930 Toll Free: 885.775.3648 r ti .2 0 FT I'l No.: 2009 -0817 KALE: N.T.S. )ate: Octobe 2 6, 2 009 HEET No. S2 EVERGREEN SCREENING EXHIBIT KROGER J904 11335 N. MICHIGAN ROAD Evans, Mechwart, Hambleton Tilton, Inc. Engineers Surveyors Planners Scientists 7400 N Sit adel and Ave„ Ste. 150, Indianapolis, IN 46250 Phone: 317.913.6930 Toll Free: 885.775.3648 r•o n-I ;OURSE ICE lei fence posts Kroger J904 a November 25, 2009 Carmel, IN 509031 architecture a e s i g r PRIVACY The beauty of wood with the benefits of vinyl available in: GALVESTON Available in 7' and 8' heights Galveston, our tallest privacy fence offers the ultimate in complete privacy and is suitable for commercial applications. V CertaGrain' Gates The perfect complement to Chesterfield CertaGrain fence, the CertaGrain gate offers durable construction and the highest quality hardware in the industry. Bufftech's premium gate includes a heavy -duty internal aluminum frame and safety features such as self closing hinges and lockable latches. GALVESTON SMOOTH FINISH/GALVESTON LATTICE ST GALVESTON VICTORIAN NOT SHOWN) Heights: T& 8', 6'8" plus 1'4" Accent Colors: White Tan Picket Style: 7/8" x 7" Tongue Groove CHESTERFIELD CERTAGRAIN GATE WITH ALUMINUM CORE Heights: 4', 5' 6' Colors: Colonial White, Natural Clay, Autumn Brown Sierra Blend Heavy -duty internal aluminum frame Colonial White Natural Clay* Autumn Brown* Sierra Blend* GALVESTON WITH CERTAGRAIN® TEXTURE Heights: T& 8' Colors: Natural Clay Sierra Blend Picket Style: 7/8" x 7" Tongue Groove Chesterfield CertaGrain Gate in Natural Clay a7AN`� CHESTERFIELD WITH CERTAGRAIN® TEXTURE Heights: 4', T& 6' Colors: Colonial White, Natural Clay, Autumn Brown Sierra Blend Picket Style: 7/8" x 7" Tongue Groove �V FT1 ��1 CHESTERFIELD WITH CERTAGRAIN® TEXTURE WITH LATTICE ACCENT Heights: 4' 10" plus 1' 3" Accent Colors: Colonial White, Natural Clay Autumn Brown Picket Style: 7/8" x 7" Tongue Groove TAB 10 49.4 sf All sign background panels to be consistent in color. Kroger sign to be internally illuminated channel letters. Colors for tenant signage to be black and white with three additional colors maximum at the discretion of the tenant. Signage occurs on both sides. 22.8 sf Signage to be internally illuminated individual channel letters (no raceway). Pricing signage to be internally illuminated, flush mounted. Signage occurs on both sides. P �er monument signs Kroger J904 C M kA architecture d e s i g n Nvember 25, 2009 Carmel, IN 509031 19' -3" CV T rrav r "Kroger" Sign 214.96 sf 18' -1" c\j Pharmacy 1 8 1 011 DRIVE -THRU signage calculations a Total Signage 329.22 sf Maer "Pharmacy" Sign 57.26 sf Individual channel letters, internally illuminated "RX Drive -Thru" Sign 57.00 sf Individual channel letters, internally illuminated Kroger J904 November 10, 2009 Carmel, IN 509031 c a hAk architecture d e s i g n U) W x� E a E cu W Co C 1 O 0 0 0 0 O ti� QD L L a 1 a W 0)Q) E co E J W V) U x L C (u (13 1 C u) L 0 U W 0 LL I I q A H Fuel logo 0.75 sf Kroger sign 1.50 sf Total signage 2.25 sf All signage on fuel dispenser is applied vinyl graphic and appears on both sides. fuel dispenser signage Kroger J904 November 25, 2009 C O'%w hAk architecture d e s i g n Carmel, IN 509031 TAB 11 3 3 ww w www X LL LL LL D D Z o D D a s s N n n n o n U �I e m e y a s a r a y i i s II I dy DESCRIPTION Q McGRAW- EDISON° Gallerie's beauty and versatility make it an excellent choice for roadway and general area lighting applications. An aesthetic reveal in the formed aluminum housing gives the Galleria a distinctive look while a variety of mounting options and lamp wattages provide maximum flexibility. Gallerie's superior light distributions makes it the optimum choice for almost any small, medium or large area lighting application. SPECIFICATION FEATURES A Housing Formed aluminum housing with stamped reveal has interior welded seams for structural integrity and is finished in premium TGIC polyester powder coat. U.L. listed and CSA certified for wet locations. B Ballast Tray Ballast tray is hard mounted to housing interior for cooler operation. C Reflector Choice of 14 high efficiency optical systems utilizing horizontal and vertical lamp orientations. Optional high efficiency segmented optical systems constructed of premium 95% reflective anodized aluminum sheet. Optical segments are rigidly mounted inside a thick gauge aluminum housing for superior protection. All segment faces are clean of rivet heads, tabs or other means of attachment which may cause streaking in the light distribution. Standard with mogul -base socket. All optical modules feature quick disconnect wiring plugs and are field rotatable in 90° increments. D Door Formed aluminum door has heavy -duty hinges, captive retaining screws and is finished in premium TGIC polyester powder coat. (Spider mount unit has steel door.) E Lens Convex tempered glass lens or flat glass. F Mounting Extruded aluminum arm includes internal bolt guides allowing for easy positioning of fixture during assembly. Specify arm included mounting for contractor friendly single carton packaging of housing and arm. GSS /GSM /GSL GALLERIA SQUARE DIMENSIONS K0 C O M P L I A N T I Fali Cutoff In all flat glass configurations. Arm Mount 70 1000W Pulse Start Metal Halide High Pressure Sodium Metal Halide ARCHITECTURAL AREA LUMINAIRE ENERGY DATA CWA Ballast Input Watts 150W MP HPF (185 Watts) 175W MP HPF (198 Watts) C 250W MP HPF (283 Watts) C 250W HPS HPF (295 Watts) 40OW MP HPF (452 Watts) C 40OW HPS HPF (457 Watts) 750W MP HPF (820 Watts) 1000W MH HPF (1080 Watts) 1000W HPS HPF (1100 Watts) FIXTURE A B C D E F GSS (in.) 91/4 11/2 127/8 155/8 6or9 31/4 (mm) 235 38 327 397 152 or 229 337 GSM (in.) 11 31/2 191/4 213/4 6 o 14 15 or 16 (mm) 279 89 480 552 152 or 356 381 or 406 GSL(in.) 141/2 41/4 257/8 27 6 o 14 183/4 or 193/4 (mm) 368 108 657 686 152 or 356 476 or 502 NOTE: Top cap used on GSM with 1000W flat glass vertically lam ped optics only. COOPER Lighting Specifications and Dimensions subject to change without notice. www.cooperlighting.com Consult your representative for additional options and finishes. EPA Effective Projected Area: (Sq. Ft.) [Without Arm] GSS: 1.20 GSM: 2.40 GSL: 3.90 [Spider Mount] GSS: 1.53 GSM: 2.86 GSL: 4.45 SHIPPING DATA Approximate Net Weight: bum GSS: 36 lbs. (16 kgs.) GSM: 79 lbs. (36 kgs.) T FRTF E GSL: 88 lbs. (40 kgs.) GS_Ga I IeriaSq_ADHO82575 12/30/2008 12:05:06 PM Spider Mount ORDERING INFORMATION GSS GSM GSL GALLERIA SQUARE Sample Number: GSM -AM- 400- MP- MT- 3V- SG -BK -L uct Family Galleria Square Small 1= Galleria Square Medium Galleria Square Large 9nting Method =Arm Mount' =Arm Included for 2 Round Pole =Arm Included for 2 Square Pole 1 Spider Mount 3 (2 3/8" OD Tenon) 2 Spider Mount (3" OD Tenon) 3= Spider Mount 4 (3 1/2" OD Tenon) 70 =70W 100=100W 150 =150W 175 =175W 200 =200W 250 =250W 320 =320W 350 =350W 400 =400W 450 =450W 750 =750W 675 =875W 1000 =1000W 0 =70W 00 =100W 50 =150W 50 =250W 00 =400W 50 =750W 000 =1000W 1H z 75 =175W 50 =250W 00 =400W 000 =1000W Notes: 1 Arm not included. See Accessories. 2Arm length varies based on housing size: 9" for GSS, 11 -1/2' for GSM and 14" for GSL. 3Available on GSS housing only. 4Available on GSL housing only. 5 Standard with medium -base sockets in GSS housing. Mogul -base sockets in GSM and GSL housings. Wattage availability varies by housing size see WattageTable. 6 Requires reduced envelope ED -28 lamp when used with GSM housing and flat glass vertically lamped optics. 7175, 250 and 40OW MH available for non -US markets only. 8 Requires reduced envelope BT-37 lamp when used with GSM housing. 9 Products also available in non -US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 10 Multi -Tap ballast is 120/208/240/277V wired 277VTriple -Tap ballast is 1 2 0127 713 47V wired 347V. 11 5 -Tap ballast is 120/20081240/277/480V wired 480V. Only available in 400- 1000W. 12 Medium housing fixture only. 13 Maximum wattage on segmented optical distributions is 400W. 40OW Metal Halide lamp must use reduced envelope ED -28 lamp. Not available in GSL housing. 14 Must use reduced envelope lamp. 15 RW optic not available with flat glass. 16 1000W GSL with flat glass requires BT -37 lamp and is not available in AS, RW or 3V distributions. 17 Other finish colors available, including a full line of FAIL color matches. Consult your Cooper Lighting Representative. 18 Add as suffix in the order shown. 19 Quartz options not available with SL optic. 20 House side shield not available with 5S, RW,AS,AR, SL and CA optics. 21 Arm mount only, 40OW maximum. 22 Order separately, replace XX with color designation. 23Available on GSM and GSL housings only. 24 Compatible with sag lens vertical optics only. STOCK SAMPLE NUMBER (Lamp Included): :essories 22 VI -EXTHS External House Side Shield (2.24 EPA) EXTHS External House Side Shield (2.46 EPA) 1004XX =14" Arm for Square Pole (1.0 EPA) za 1005XX =6" Arm for Square Pole (0.5 EPA) z3 1006XX Direct Mount Kit for Square Pole z3 1007XX =14" Arm for Round Pole (1.0 EPA) za 1008XX =6" Arm for Round Pole (0.5 EPA) z3 1009XX Direct Mount Kitfor Round Pole za 1021 X =6" Arm for Square Pole (0.5 EPA) 3 1022XX =6" Arm for Round Pole (0.5 EPA) 3 1023XX =9" Arm for Square Pole (0.5 EPA) 3 1024XX =9" Arm for Round Pole (0.5 EPA) 3 1029XX =Wall Mount Bracket with 10" Arm 1046XX =Wall Mount Bracket 1208XX =11 1/2" Arm and Round Pole Adapter (0.8 EPA) 1066XX =Mast Arm Adapter 1010XX Single Tenon Adapter for 31/2' O.D. Tenon 1011XX =2 @180 Tenon Adapter for 31/2' O.D. Tenon 1012XX =3 @120 Tenon Adapter for 31/2' O.D. Tenon 1013XX =4 @90 Tenon Adapter for 31/2' O.D. Tenon 1014XX =2 @90o Tenon Adapter for 31/2' O.D. Tenon 1015XX =2 @120 Tenon Adapter for 31/2' O.D. Tenon 1016XX =3 @90o Tenon Adapter for 31/2' O.D. Tenon 1017XX Single Tenon Adapter for 23/8 "O.D. Tenon 1018XX =2 @180 Tenon Adapter for 23/8 "O. D. Tenon 1019XX =3 @120 Tenon Adapter for 23/8 "O.D. Tenon 1045XX =4 @90 Tenon Adapter for 2 3/8" O.D. Tenon 1048XX =2 @90 Tenon Adapter for 23/8 "O.D. Tenon 1049XX =3 @90o Tenon Adapter for 23/8 "O. D. Tenon 1060 =House Side Shield for GSS 24 (Field Installed) 1061 =House Side Shield for GSM 24 (Field Installed) 1062 =House Side Shield for GSL 24 (Field Installed) IRA1016 NEMATwistlock Photocontrol Multi Tap IRA1027 NEMATwistlock Photocontrol 480V SAMPLE NUMBER: GSM -AI- 400- MP- MT- AS- FG -BZ -L GSM Al Product Mounting Lamp Ftal pe Family Method Wattage se Start GSM= Galleria Meth 1/2" 320 =320W Halide Square Arm 400 =400W tal Halide' Medium Included 1000 =1000W NOTES stock]: Other options not available with stock products. 'Only availabh BZ L Voltage FAS=Area Lens Type Color MT= Multi -Tap Wired 277V FG =Flat Glass BZ= Bronze L =L amp 5T =5 -Tap Wired 480V 1 cal SG =Sag Glass Included with 1000W. COOPER Lighting Specifications and Dimensions subject to change without notice. GS_Galleriasq_ADH082575 www.cooperlighting.com McGraw- Edison Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 12/30/2008 12:05:06 PM imp Type Distribution Color 17 IP =Pulse Start Metal Horizontal Lamp AP =Grey Halide 1F =Type I Formed 12 BZ= Bronze PS =High Pressure 2F =Type 11 Formed BK =Black Sodium 13 2S =Type II Segmented =White IH =Metal Halide z yyH 3F =Type III Formed 3S =Type III Segmented 13 DP =Dark Platinum GM= Graphite Metallic oltage 9 20 =120V 4S =Type IV Segmented 13 )8 =208V 5S =Type V Segmented 13 Options 18 30 =240V FT= Forward Throw F= Single Fuse (120, 277 or SL =Spill Light Eliminator 14 347V) 77 —277V FF= Double Fuse (208, 240 or 30 =480V CA =Cutoff Asymetric 480V) with EHS IT =Multi -Tap 10 EM =Quartz Restrike w/ Delay 19 r= Triple -Tap 'o Vertical Lamp AR =Area Round Q =Quartz Restrike 1s r =5 -Tap 11 AS =Area Square R= NEMATwistlock Photocontrol Receptacle 3V =Type III Vertical HS—House Side Shield RW= Rectangular Wide 's EHS External Adjustable House Side Shield Lens Type VS= Vandal Shield 21 FG Flat Glass 16 L =Lamp Included S Glass Notes: 1 Arm not included. See Accessories. 2Arm length varies based on housing size: 9" for GSS, 11 -1/2' for GSM and 14" for GSL. 3Available on GSS housing only. 4Available on GSL housing only. 5 Standard with medium -base sockets in GSS housing. Mogul -base sockets in GSM and GSL housings. Wattage availability varies by housing size see WattageTable. 6 Requires reduced envelope ED -28 lamp when used with GSM housing and flat glass vertically lamped optics. 7175, 250 and 40OW MH available for non -US markets only. 8 Requires reduced envelope BT-37 lamp when used with GSM housing. 9 Products also available in non -US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 10 Multi -Tap ballast is 120/208/240/277V wired 277VTriple -Tap ballast is 1 2 0127 713 47V wired 347V. 11 5 -Tap ballast is 120/20081240/277/480V wired 480V. Only available in 400- 1000W. 12 Medium housing fixture only. 13 Maximum wattage on segmented optical distributions is 400W. 40OW Metal Halide lamp must use reduced envelope ED -28 lamp. Not available in GSL housing. 14 Must use reduced envelope lamp. 15 RW optic not available with flat glass. 16 1000W GSL with flat glass requires BT -37 lamp and is not available in AS, RW or 3V distributions. 17 Other finish colors available, including a full line of FAIL color matches. Consult your Cooper Lighting Representative. 18 Add as suffix in the order shown. 19 Quartz options not available with SL optic. 20 House side shield not available with 5S, RW,AS,AR, SL and CA optics. 21 Arm mount only, 40OW maximum. 22 Order separately, replace XX with color designation. 23Available on GSM and GSL housings only. 24 Compatible with sag lens vertical optics only. STOCK SAMPLE NUMBER (Lamp Included): :essories 22 VI -EXTHS External House Side Shield (2.24 EPA) EXTHS External House Side Shield (2.46 EPA) 1004XX =14" Arm for Square Pole (1.0 EPA) za 1005XX =6" Arm for Square Pole (0.5 EPA) z3 1006XX Direct Mount Kit for Square Pole z3 1007XX =14" Arm for Round Pole (1.0 EPA) za 1008XX =6" Arm for Round Pole (0.5 EPA) z3 1009XX Direct Mount Kitfor Round Pole za 1021 X =6" Arm for Square Pole (0.5 EPA) 3 1022XX =6" Arm for Round Pole (0.5 EPA) 3 1023XX =9" Arm for Square Pole (0.5 EPA) 3 1024XX =9" Arm for Round Pole (0.5 EPA) 3 1029XX =Wall Mount Bracket with 10" Arm 1046XX =Wall Mount Bracket 1208XX =11 1/2" Arm and Round Pole Adapter (0.8 EPA) 1066XX =Mast Arm Adapter 1010XX Single Tenon Adapter for 31/2' O.D. Tenon 1011XX =2 @180 Tenon Adapter for 31/2' O.D. Tenon 1012XX =3 @120 Tenon Adapter for 31/2' O.D. Tenon 1013XX =4 @90 Tenon Adapter for 31/2' O.D. Tenon 1014XX =2 @90o Tenon Adapter for 31/2' O.D. Tenon 1015XX =2 @120 Tenon Adapter for 31/2' O.D. Tenon 1016XX =3 @90o Tenon Adapter for 31/2' O.D. Tenon 1017XX Single Tenon Adapter for 23/8 "O.D. Tenon 1018XX =2 @180 Tenon Adapter for 23/8 "O. D. Tenon 1019XX =3 @120 Tenon Adapter for 23/8 "O.D. Tenon 1045XX =4 @90 Tenon Adapter for 2 3/8" O.D. Tenon 1048XX =2 @90 Tenon Adapter for 23/8 "O.D. Tenon 1049XX =3 @90o Tenon Adapter for 23/8 "O. D. Tenon 1060 =House Side Shield for GSS 24 (Field Installed) 1061 =House Side Shield for GSM 24 (Field Installed) 1062 =House Side Shield for GSL 24 (Field Installed) IRA1016 NEMATwistlock Photocontrol Multi Tap IRA1027 NEMATwistlock Photocontrol 480V SAMPLE NUMBER: GSM -AI- 400- MP- MT- AS- FG -BZ -L GSM Al Product Mounting Lamp Ftal pe Family Method Wattage se Start GSM= Galleria Meth 1/2" 320 =320W Halide Square Arm 400 =400W tal Halide' Medium Included 1000 =1000W NOTES stock]: Other options not available with stock products. 'Only availabh BZ L Voltage FAS=Area Lens Type Color MT= Multi -Tap Wired 277V FG =Flat Glass BZ= Bronze L =L amp 5T =5 -Tap Wired 480V 1 cal SG =Sag Glass Included with 1000W. COOPER Lighting Specifications and Dimensions subject to change without notice. GS_Galleriasq_ADH082575 www.cooperlighting.com McGraw- Edison Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 12/30/2008 12:05:06 PM P HOTOM ETR ICS 3 2 1 A BC D E 0 1 2 3 4 0 1 2 3 4 5 GSM -XX- 1000 -M H -S L -FG 1000 -Watt MH 110,000 -Lumen Clear Lamp Spill Light Eliminator Flat Glass WATTAGE TABLE 1"■■ r iii rrr 1 men Clear Lamp Type III Vertical Flat Glass \tl■ ■MINE .01111■■ IN ►II■ r iii rrr 0,000-Lumen Area Square Flat Glass Fixture Size Wattage GSS Pulse Start Metal Halide (MP) 70, 100, 150W High Pressure Sodium (HPS) 70, 100, 150W Metal Halide (MH) 175W GSM Pulse Start Metal Halide (MP) 70, 100, 150, 175, 200, 250, 320, 350, 400, 450, 750, 875, 1000W High Pressure Sodium (HPS) 70,100,150, 250 400 750 1000W Metal Halide (MH) 175, 250, 400, 1000W GSL 0.15 Pulse Start Metal Halide (MP) 250, 320, 350, 400, 450, 750, 1000W High Pressure Sodium (HPS) 250,400, 750 1000W Metal Halide (MH) 250,400, 1000W 0.07 40' 2.00 1.00 0.50 Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D E 1000W [SL] 40OW [AR] 25' 2.88 1.44 0.72 0.29 0.14 30' 2.00 1.00 0.50 0.20 0.10 35' 1.46 0.73 0.37 0.15 0.07 1000W [3V /AS] 30' 3.50 2.00 1.00 0.50 0.20 35' 2.60 0.73 0.37 0.18 0.07 40' 2.00 1.00 0.50 0.20 0.10 DRILL PATTERN TYPE "M" 2 5/16" [59mm] 3/4" [20mm] Dia. Hole 2 7/16" [124mm] 4 7/8" [124mm] (2) 5/8" [16mm] Dia. Holes COOPER Lighting Specifications and Dimensions subject to change without notice. GS_GalleriaSq_ADH082575 www.cooperlighting.com McGraw- Edison Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 12/30/2008 12:05:06 PM TYPE: CATALOG 4: C OOPER LIGHTING° DETAILS RTSROUND TAPERED STEEL 2 0 5 0 Mounting Height ROUND TAPERED STEEL MH ing height) 3 U -I handhole 1 •ASTM Grade steel base plate with ASTM A366 base cover. 12 5/16" _J -1 2 Hand hole assembly 3" x 5" on on RTS poles. II L61 3 Steel shaft minimum yield 55,000 PSI. Shot blasted and painted with polyester powder coat. p 4•••Drilled or Tenon (specify). 0 5 •Anchor bolt per ASTM A576 with (2) nuts, (2) flat washer, and (1) lock b washer. Nuts, washers and threaded portion of bolt are hot dip Base View galvanized. 3" hook for 3/4" bolt. 4" hook for 1" bolt. �S� FOUR BOLT ANCHORAGE (see ordering information) BC =Bolt Circle BC BP =Bolt Projection AB =Bolt Dimensions D =Bolt Diameter D H =Bolt Dimensions �000 o BP 00 FINISH COLORS F =Dark Bronze ao 000 AB G= Galvanized 000aa oo �o Do S= Silver o oQp o V =Grey L W =White H I Y =Black e� COOPER LIGHTING ADH020020 F P1 I I 1FRT RTSROUND TAPERED STEEL The following information illustrates the correct way to enter an order for RTS8A30SF2XXG. The ordering designation is detailed as follows. Designation Designation (UCS Only) Mounting Fixture No. Accessories Letter Number Shaft' Wall Height Base Mounting Location Arm (Ground Round Tapered Steel Size Thickness (ft.) Type Finish Type of Arms Lengths Lug) R T S 8 A 30 S F 2 X X G Z4 4 90° Bolt Anchor Z5 2 Cn 90° M6 Base Circle Bolt Shaft Bolt Net. M7 Max. Fixture Mtg. Catalog" Wall Square Dia. Proj. Size Dia. Wt. EPA (Sq. Ft.)° EPA (Sq. Ft.) Load Include Height Number Thickness (I n.) (In.) (In.) (In.) Length (In.) (Lbs.) At Pole Top 2' Above Pole Top Bracket (Lbs.) MH S BC BP B AB 70 80 90 100 70 80 90 100 20 RTS6A20SF .120 101/2 11.0 41/2 6.3 x 3.5 3/4 x 25 x 3 173 29.8 22.7 17.8 14.3 27.1 20.6 16.2 13.1 400 25 RTS7A25SF .120 101/2 11.0 41/2 7.0 x 3.5 3/4 x 25 x 3 214 28.1 21.4 16.7 13.4 26.0 19.8 15.5 12.5 400 30 RTS8A30SF .120 121/2 12.5 5 7.7 x 3.5 1 x 36 x 4 290 24.0 18.2 14.2 11.3 22.5 17.0 13.3 10.6 400 35 RTS8A35SF .120 121/2 12.5 5 8.4 x 3.5 1 x 36 x 4 342 23.0 17.3 13.5 10.5 21.7 16.4 12.7 9.9 400 35 RTS9D35SF .180 121/2 12.5 5 8.4 x 3.5 1 x 36 x 4 482 38.9 29.6 23.2 18.3 36.8 28.0 21.9 17.3 400 39 RTS9A39SF .120 121/2 12.5 5 8.9 x 3.5 1 x 36 x 4 341 21.5 16.2 12.4 9.5 20.5 15.4 11.8 9.0 400 39 RTS9D39SF .180 121/2 12.5 5 8.9 x 3.5 1 x 36 x 4 536 38.2 29.0 22.5 17.7 36.4 27.6 21.4 16.8 400 45 RTSOA45SF s .120 131/2 13.5 5 10.2 x 4.2 1 x 36 x 4 546 23.5 17.4 12.9 9.7 22.5 16.6 12.4 9.3 450 45 RTSOD45SF s .180 131/2 13.5 6 10.2 x 4.2 1 1/4 x 42 x 6 682 44.1 33.2 25.4 19.8 42.2 31.7 24.3 19.0 450 50 RTSOA50SF 5 .120 131/2 13.5 5 10.2 x 3.5 1 x 36 x 4 550 15.2 11.0 7.9 5.7 14.8 10.6 7.6 5.4 450 50 RTSOD50SF 5 .180 131/2 13.5 6 10.2 x 3.5 1 1/4 x 42 x 6 719 31.0 23.1 17.5 13.4 29.8 22.2 16.8 12.9 450 NOTES: 1 Catalog number includes pole with anchor bolts with double nuts (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING). 2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180° from single arm. 3 Shaft size, base plate, anchor bolts and projections may vary slightly -all dimensions nominal. 4 EPA's based on shaft properties with wind normal to flat. EPA's calculated using base wind velocity as indicated plus 30% gust factor. 6 Two piece pole. Shipped in two sections and is easily joined together at the job site by slip- fitting together. DRILLING PATTERN MOUNTING OPTIONS (add as suffix) Type "M" Type "E" Type "Z" Fixed Tenon Designation O.D. Length Number (In.) (In.) O D 1 23/8 31/2 25/16" 2 13/16" 3/4" 4" [102mml 2 23/8 4 9/16" dia. 3 31/2 5 2 7/16" dia. holes hole 7/8 2 7/16" [62mm] LENGTH 9 3 4 4 7/8" [124mml 4 7/8" 3 7/8" 9/16" [14mml 11/32' dia. dia. hole (3) holes L Required) Type "M" Drill Pattern Hammer, Landau, Galleria, and Vision Area Type "E" Drill Pattern Concourse III Type "Z" Drill Pattern Credenza and Cirrus MACHINING FOR RECTANGULAR ARMS (add as suffix) Designation Designation (UCS Only) Designation (Cirrus/ Credenza Only) Quantity Letter Number Letter Number Letter Number Location M1 E1 Z1 Single M2 E2 Z2 29180 M3 E3 Z3 39120 M4 E4 Z4 4 90° M5 E5 Z5 2 Cn 90° M6 E6 Z6 3@)90 M7 E7 Z7 2 Ca 120° ACCESSORIES A=11/2" tapped hub' B=3/4" tapped hub' C= Convenience outlet G= Grounding lug (max. wire #8 AWG) H= Additional hand hole and cover 12" below pole top -90° from hand hole. NOTES: 1 Location is T above base -90° from hand hole. 2 Outlet is located 4' above base and on same side of pole as hand hole, unless specified otherwise. Receptacle not included, provision only. NOTE: Specifications and dimensions subject to change without notice. 0 Visit our web site at www.cooperlighting.com COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADHO20020 NCORE® FLAT LENS DOUBLE OR SINGLE DECK APPLICATIONS HOUSING Die -cast, one -piece aluminum ensures durable, weather -tight construction. Two threaded conduit openings allow through wiring. LENS /GASKET Choose either a flat clear tempered glass lens or a C73 diffused flat tempered glass lens. A continuous one -piece extruded high temperature gasket ensures maximum sealing to the housing. LENS FRAME /DOOR FASTENER Features an integral hinged, die -cast aluminum lens frame. Door frame closes and locks with stainless steel spring catch, allowing easy access for ground re- lamping. INSTALLATION One- person installation. No additional sealant required. REFLECTORS /DISTRIBUTION PATTERNS The vertical burn optical system and symmetrical reflector provide uniform general lighting under the canopy. LIGHT SOURCES Pulse -Start Metal Halide or Metal Halide Reduced Envelope. BALLASTS High -power factor type ballasts. Pulse -Start Metal Halide features Super CWA ballasts and Metal Halide features CWA ballasts. Ballasts are designed for -20 degree F operation. Electrical components are serviceable from below. FINISH Standard colors are white or bronze powder coat finish. Each fixture is finished with LSI's DuraGrip® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling, and is guaranteed for five full years. WARRANTY The Encore carries a comprehensive 5 -year warranty on all parts, finish, workmanship and electrical components (excluding lamp). PHOTOMETRICS For detailed photometric data, contact LSI Petroleum Lighting Sales. C US LISTED wet location C E Consult Factory. 2004 LSI INDUSTRIES INC. 1 Flat- lensed fixtures full SNA cu O'classification. full cut -off Protected by the following patents: 5,662,407 6,059,422 6,152,579 6,224,233 6,464,378 Patentado 199,294 CA2276077 CA2381049 and Pat. Pend. 12 12" Deck requires 12" opening with 2" radius corners. Project Name t Fixture Type NOTE: Encore cannot be mounted in a single skin canopy with 12" deck pans. Catalog t ENCORE° FLAT LENS DOUBLE OR SINGLE DECK APPLICATIONS LUMINAIRE ORDERING INFORMATION EC I S Symmetrical EXAMPLE OF ATYPICAL ORDER 175 PSMV Pulse -Start Metal Halide 200 175, 200, 250, 320 Watt 250 320 MHR Metal Halide Reduce 400 400 Watt F Clear Flat Tempered Glass C73 Diffused Flat Tempered Glass EC S 250 PSMV F MT WHT 1- MT— Multi Tap is shipped standard unless otherwise specified. Multi Tap consists of 120V, 208V, 240V, and 277V. Multi Tap is pre -wired for 277V. Alternate voltages will require field re- wiring. 2- Tri -Tap is shipped standard for Canadian applications. Tri -Tap consists of 120V, 277V, and 347V. Tri -Tap is pre -wired for 347V. Alternate voltages will require field re- wiring. 3- Order when fixtures are to be used in enclosed ceilings. Voltage must be specified 120V, 208V, 240V, 277V, 347V or 220V 50Hz. 4- Consult Factory. Description Order Number ECKEC Thin Canopy Kit for Encore 176008 Ground Lamp Changers: 250, 320, 400 (Reduced) Watt 132678A 200 Watt 179101Z UPTURNED (8) SUPPORT ROOF FLANGE WIRE HOLES UPTURNED FLANGE 0 o OF MOUNT BRACKET 0 MOUNT CEILING BRACKET 174806 DDM For use in covered areas (i.e. water proof plenum) where ceiling material will not support the fixture or access is not available from above to utilize standard locking ring. TABS RED GASKET BETWEEN PANEL AND DECK DECK 'ANEL SDRP Single deck decorative retrofit panel facilitates conversions from 2x2 surface mounted fixture to Encore. (8) SUPPORT WIRE HOLES no ROOF UPTURNED FLANGES UPTURNED CEILING FLANGE DECORATIVE PANEL 177825 DDRMP Decorative retrofit panel is for use on double deck canopies only. Panel will structurally support the Encore while covering an opening up to 600mm by 600mm. For use in covered areas only (i.e water proof plenum). Project Name i Fixture Type i MT Multi -Tap' I WHT White TT Tri BRZ Bronze 220V 50Hz II TH Thermally Protected CE European Compliant 2004 LSI INDUSTRIES INC. Catalog H H LL d LO N Ch t t7 8 s O H: C.] W ui a N awl t7 8 s O H: C.] W ui a N COOPER LIGHTING LUMARKO DESCRIPTION The Lumark Tribute is the most versatile, functionally designed, universally adaptable outdoor luminaire available. The Tribute brings outstanding performance to walkways, parking lots, roadways, loading docks, building areas, and any security lighting application. U.L. listed and CSA certified for wet locations. IP55 Rating. SPECIFICATION FEATURES Construction Rugged one -piece die -cast aluminum housing and door frame. One -piece silicone gasket protects the optical chamber from performance degrading contami- nants. One (1) stainless spring latch and two (2) stainless hinges allow toolless opening and removal of door frame. Reflector Choice of nine (9) high efficiency optical distributions, including five (5) segmented optical systems constructed of premium 95% reflective anodized aluminum sheet. Optical segments are rigidly mounted inside a thick gauge aluminum housing for superior protection. All segment faces are clean of rivet heads, tabs or other means of attachment which may cause streaking in the light distribution. Optical modules are field rotatable in 90° increments and offered standard with mogul- DIMENSIONS 6 1/2" [165 mm] 15 1/2" [394mm] DRILLING PATTERNS round pole adapter allow for consolidated product arrival to site. Optional internal mast arm mount accepts a 1 1/4" to 2 3/8" O.D. horizontal tenon, while a 4 -bolt clamping mechanism secures fixture. Cast -in leveling guides provide -5° vertical leveling adjustment. Finish Housing and arm finished in a 5 stage premium TGIC bronze polyester powder coat paint. Optional colors include black, grey, white, dark platinum and graphite metallic. RAL and custom color matches available. oft. TR TRIBUTE 70 40OW High Pressure Sodium Pulse Start Metal Halide Metal Halide AREA LU MINAIRE LAMP TYPE WATTAGE Metal Halide 70, 100, 175, 250, 400W High Pressure Sodium 70, 100, 150, 250, 40OW Pulse Start Metal Halide 250, 320W 1 22" [559mm] 1 8" [203m TYPE "M" 2 5/16" WALL MOUNT [59mm] 12" 3/4" [20mm] [305mm] dia. hole 47/8" 2 7/16" [124mm] O [124mm] 10 1/2" 4 7/8" [124mm] [267mm] (2) 5/8" [16mm] 9/16" [14mm] 61/2" dia. holes [165mm] Dia. Hole (4) S" [203mm] base lampholders for 150 -40OW assemblies or medium -base lampholders for 100W and below. Electrical Ballast and related electrical componentry are hard mounted to die -cast housing for optimal heat transfer and operating efficiency. Optional swing -down galvanized steel power tray with integral handle and quick disconnects allows tray to be completely removed from housing providing ample room for fixture installation and maintenance. Mounting Extruded 8" aluminum arm features internal bolt guides for easy positioning of fixture during installation to pole or wall surface. Standard single carton packaging of housing, square pole arm and TRUNNION MOUNT 7/16" [12mm] 13/32" x3/4" [20mm] [11mm] slot (2) slot L 1 1/2" [39mm] 3" [77mm] 1" [25mm] 11 FCO COMPLIANT Fa to ENERGY DATA Hi- Reactance Ballast Input Watts 70W HPS HPF (95 Watts) 10OW HPS HPF (130 Watts) 150W HPS HPF (190 Watts) 150W MH HPF (185 Watts) CWI Ballast Input Watts 250W HPS HPF (300 Watts) CWA Ballast Input Watts 175W MH HPF (210 Watts) 20OW HPS HPF (250 Watts) 250W MH HPF (295 Watts) 320W MP HPF (365 Watts) 40OW MP HPF (448 Watts) 40OW MH HPF (455 Watts) 40OW HPS HPF (465 Watts) EPA Effective Projected Area: (Sq. Ft.) Without Arm: 1.19 SHIPPING DATA Approximate Net Weight: by 391bs. (17.73 kgs.) o COOPER Lighting Specifications and Dimensions subject to change without notice. ADH071304 www.cooperlig hti ny.com Consult your representative for additional options and finishes. 02/25/2008 4:34:03 PM TR TRIBUTE ORDERING INFORMATION Sample Number: MHTR- SL400 -MT -LL STOCK SAMPLE NUMBER (Lamp Included) SAMPLE NUMBER: MHTR2340 TR FW Lamp Type Series' r25=25OW attage HP =High TR= Tribute W Pressure Sodium MH =Metal W Halide NOTES: Short logicfixtures arefinished bronze include multi -tap ballast, lamp, arm and round pole adapter. Other options not available. Referto standard ordering logic. COOPER Lighting Specifications and Dimensions subject to change without notice. ADH071304 www.cooperlighting.com Lumark Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 02/25/2008 4:34:03 PM Lamp Type Distribution Lamp Wattage 2 Options 7-8 Accessories 2 HP= High Pressure Sodium 2F= Type II Formed 70= 70W F1= Single Fuse (120, 277 or 347V MAl201 -)IX= Direct Wall Mount Kitt III Metal Halide 2S= Type 11 100 =100W only) MAl218- XX= Direct MountforPolet III Pulse Start MH (CWA) Segmented 150= 150W F2= Double Fuse (208, 240 or 48OV MAl219-XX= Wall Bracketwith 8 "Arm 3F= Type III Formed 175= 175W only) OA1090_XX= Adjustable slipfitter Arm for Tenon Mount 2 3/8" O.D.1 Series 3S= Type III 250 =250W a= Qu Restrike (Hot Strike 16 MAl221 -XX= External House Side Shield Kit (EPA= 0.38) TR= Tribute (Arm Included) g 320 320W 3 Only "Delay MA7222= External House Side Shield Kit for 2S 13S 4F= Type IV Formed EM= Quartz Restrike with 16 NIp1223= Internal House Side Shield Kit 4S 400 =400W4 Relay" l strikes at 4S =Type IV both hot t and and cold starts) MAl224= Internal House Side Shield Kit for 2F 13F Segmented Voltages EM/SC= Emergency Separate '6 MAl225= Internal House Side Shield Kd for4F 5F= Type V Formed Circuit MA1010 -XX= SingleTenon Adapter for 31/2" O.D. Tenon 120V= 120V 5S= Type V LL= Lamp Included MA1011 -XX= 2 180 degrees Tenon Adapter for 3 1/2" O.D.Tenon Segmented 208V= 208V S= 1 1/4" 2 3/8" Internal Mast Arm MA1012 -XX= 3 120 degrees Tenon Adaptor for 3 1/2" O.D. Tenon SL= Spill Light 240V= 240V Mount MA1013 -XX= 4 90 degrees Tenon Adapter for 3 1/2" O.D. Tenon Eliminator 277V 277V TM= Trunnion Mount MA1014 -XX= 2 90 degrees Tenon Adapter for 3 1/2" O.D. Tenon 347V= 347V Pr= Electrical Power Tray MA1015 -)[X= 2 120 degrees Tenon Adapter for 3 1/2" O.D.Tenon 480V= 480V HS= House Side Cutoff" MA1016 -XX= 3 90 degrees Tenon Adapter for 31/2" O.D. Tenon DT= Dual -Tap6 LA= Less Arm (Order Mounting MA1017 -XX= Single Tenon Adapter for 2318 "O.D. Tenon MT MUlti -Tap, 6 Separately) MA1018 -XX= 2 180 degrees Tenon Adapter for 2 3/8" O.D. Tenon wired 277V PER NEMA Twistlock Photocontrol MA1019 -XX= 3 120 degrees Tenon Adapter for 2 30' O.D. Tenon TT= Triple -Tap, 6 Receptacle MA1045 -)[X= 4 90 degrees Tenon Adapter far 2 3/8" O.D. Tenon wired 347V PC= Button Type Photocontrol YP MA1048 -)[X= 2 90 degrees Tenon Adapter for 2 3/8" O.D.Tenon 5T= 5 Tap Wired WH= White MA1049 -XX= 3 90 degrees Tenon Adapter for 2 3/8" O.D. Tenon 480V B K= Black OARA1016= Photoelectric Control 105 -285V NEMA Type AP= AP Grey OARA1027= Photoelectric Control 480V NEMA Type DP= Dark Platinum OA/RA1021= Photoelectric Control 347V NEMA Type GM= Graphite Metallic OARA1013= Shorting Cap TRA/S= Field Installed Vandal Shield 13 Notes: 1 8 Inch Arm and pole adapter included with fixture. Specify Less Arm "LA" option when mounting accessory is ordered separately. 2 Standard with mogul -base socketfor 150 -40OW and medium -base socket 10OW and below. 3 320W Pulse Start Metal Halide lamps only. 4 Requires reduced envelope lamp. 5 Products also available in non -US voltages and 50HZ for international markets. Consultfactory for availabiltiy and ordering information. 6 Dual -Tap is 120/277V wired 277V. Multi -Tap is 120/208/2401277V wired 277V. Triple -Tap ballast is 120/277/347V wired 347V. 5 -Tap is 120/2081240/277/480V wired 480V.. 7 Custom and RAL color matching available upon request. Consult Cooper Lighting Representative for further information. 8 Add as a suffix. 9 Must specify voltage. 19 Quartz options not available with SL optics. 11 House side shield not available on 5S, 5F, or SL optics. 12 Order separately/ replace XX with color specification. 13 Not available with SUE or House Side Sheild. STOCK SAMPLE NUMBER (Lamp Included) SAMPLE NUMBER: MHTR2340 TR FW Lamp Type Series' r25=25OW attage HP =High TR= Tribute W Pressure Sodium MH =Metal W Halide NOTES: Short logicfixtures arefinished bronze include multi -tap ballast, lamp, arm and round pole adapter. Other options not available. Referto standard ordering logic. COOPER Lighting Specifications and Dimensions subject to change without notice. ADH071304 www.cooperlighting.com Lumark Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 02/25/2008 4:34:03 PM PHOTOMETRICS [Complete IES files available at www.cooperlighting.coml 4 3 2 1 A B C D E 0 1 2 3 4 5 4 3 2 1 0 1 2 3 4 5 MHTR -3S -400 400 -Watt MH Type III Segmented 40,000 -Lumen Clear Lamp Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D E 20' 3.00 1.50 0.75 0.30 0.15 25' 2.00 1.00 0.50 0.20 0.10 30' 1.36 0.69 0.34 0.13 0.06 MOUNTING CONFIGURATIONS 4 3 2 1 JA D E 0 1 2 3 4 5 4 3 2 1 0 1 2 3 4 5 MHTR -4S -400 400 -Watt MH Type IV Segmented 40,000 -Lumen Clear Lamp Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D E 20' 3.00 1.50 0.75 0.30 0.15 25' 2.00 1.00 0.50 0.20 0.10 30' 1.36 0.69 0.34 0.13 0.06 4 3 2 1 A D 0 1 2 3 4 5 4 3 2 1 0 1 2 3 4 5 MHTR -SL -400 400 -Watt MH Spill Light Eliminator 40,000 -Lumen Clear Lamp Footcandle Table Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines A B C D E 20' 3.00 1.50 0.75 0.30 0.15 25' 2.00 1.00 0.50 0.20 0.10 30' 1.36 0.69 0.34 0.13 0.06 Wall Mount Arm Mount Single Arm Mount 2 160 Arm Mount 2 90 Arm Mount 3 120 Arm Mount 3 90 Arm Mount 4 90 EPA: 1.62 EPA: 3.24 EPA: 3.24 (Round Pole Only) EPA: 4.43 EPA: 5.03 EPA: 4.43 COOPER Lighting Specifications and Dimensions subject to change without notice. ADH071304 www.cooperlighting.com Lumark Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 TEL 770.486.4800 FAX 770.486.4801 02/25/2008 4:34:03 PM ENCORE FOCUS DOUBLE OR SINGLE DECK APPLICATIONS DIMENSIONS 16" 17 17' Deck requires 12" opening with 2" radius corners. SHIPPING WEIGHT Est. Weight (lbs.) 42 08/07/09 2009 LSI INDUSTRIES INC Project Name I Fixture Type I Catalog NOTE: Encore cannot be mounted in a single skin canopy with 12" deck pans. Protected by the following patents: D482,480 5,662,407 6,059,422 6,224,233 Patentado 199,294 CA2276077 CA2381049 and Pat. Pend. HOUSING Die -cast, one -piece aluminum ensures durable, weather -tight construction. Two threaded conduit openings allow through wiring. DOOR FRAME /DOOR FASTENER Features an integral hinged, die -cast aluminum door with a powder coat finish. Door frame closes and locks with stainless steel spring catch. INSTALLATION One- person installation. No additional sealant required. OPTICAL ASSEMBLY The optical assembly directs light specifically to the area you wish to light. To allow for proper aiming, the FO optic can be adjusted vertically to concentrate the light beam center at 24 30° or 36° from nadir. The ADJ optic can be externally adjusted to concentrate the light beam center from 20° to 40° from nadir. Both optics are adjustable horizontally 350 LIGHT SOURCES Ceramic Metal Halide PAR lamp. BALLASTS High -power factor type HX -HPF ballast is designed for -20 degree F operation. Electrical components are serviceable from below. FINISH Standard colors are white or bronze powder coat finish. Each fixture is finished with LSI's DuraGrip° polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling, and is guaranteed for five full years. WARRANTY The Encore carries a comprehensive 5 -year warranty on all parts, finish, workmanship and electrical components (excluding lamp). PHOTOMETRICS For detailed photometric data, contact LSI Petroleum Lighting Sales. c us LISTED wet location Petroleum Lighting' ENCORE FOCUS DOUBLE OR SINGLE DECK APPLICATIONS LUMINAIRE ORDERING INFORMATION TYPICAL ORDER EXAMPLE: EC SP 100 P38MH FO MT WHT Lumi Distribution Light Source naire Di Lamp Line Luminaire Prefix Wattage g Lens Voltage Finish Options EC SP 100 P38MH PAR 38 Ceramic FO Focus MT Multi -Tap' WHT White IL Internal Louver N Spot N 1 6 +6 Metal Halide 100 Watt ADJ Externally TT Tri -Tape BRZ Bronze N N N +6 +6 Adjustable Optics 220v 50Hz N N FOOTNOTES: 1- MT— Multi Tap consists of 120V, 208V, 240V and 277V and is prepared for highest voltage. ACCESSORY ORDERING INFORMATION (Accessories are field installed) Alternate voltages will require field adjustment. Description Order Number 2- TT —Tri -Tap consists of 120V, 277V and 347V and is shipped standard for Canadian applications TCKEC -Thin Canopy Kit for Encore 176008 and is prepared for highest voltage. Alternate voltages will require field adjustment. DOM DOUBLE DECK MOUNTING BRACKET (ORDER NUMBER 174806) UPTURNED (8) SUPPORT LNT ROOF FLANGE WIRE HOLES c ANGE RACKET CEILING BRACKET 174806 DDM For use in covered areas (i.e. water proof plenum) where ceiling material will not support the fixture or access is not available from above to utilize standard locking ring. LIGHT DISTRIBUTION FO OPTICS DISTANCE FROM PUMP CENTER, "B" SDRP SINGLE DECK RETROFIT PANEL (ORDER NUMBER 180292) TABS RED GASKET BETWEEN PANELAND DECK DECK 'ANEL SDRP Single deck decorative retrofit panel facilitates conversions from 2x2 surface mounted fixture to Encore. DDRMP DOUBLE DECK RETROFIT MOUNTING PANEL (ORDER NUMBER 177825) (8) SUPPORT ROOF WIRE HOLE no /-UPTURNED FLANGES UPTURNED CEILING FLANGE DECORATIVE PANEL 177825 DDRMP Decorative retrofit panel is for use on double deck canopies only. Panel will structurally support the Encore while covering an opening up to 600mm by 600mm. For use in covered areas only (i.e water proof plenum). LAMP LAYOUT FOR 25° FLOOD CANOPY HEIGHT, "A" e, 6' F 9 Fy A VERTICAL HEIGHT OF CANOPY B -T78 8" HORIZONTAL DISTANCE FROM WALL TO CENTER OF FIXTURE 5' 4" 6' 6' 8" T 4" 8' 8' 8 9'4" 10' 16' -6 -6 -6 1 N N N N 1 6 +6 15 1/2' -6 -6 N N N N +6 +6 -6 -6 N N N N +6 +6 k 14 15' 1 1/2' -6 -6 N N N +6 +6 14' -6 -6 N I N N +6 +6 PUMP TYR HEIGHT (TYP.4') l 08/07/09 2009 LSI INDUSTRIES INC. Project Name Catalog Fixture Type 10° 10° 30° Factory Setting r 9rP �d0 m e3 P i NADIR Petroleum Lighting' INSTALLATION INSTRUCTIONS PRODUCT: GALLER I A IMI -428 MPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE GENERAL: UPON RECEIPT OF FIXTURE THOROUGHLY INSPECT FOR ANY SAFETY: THIS FIXTURE MUST BE MIRED IN ACCORDANCE WITH THE FREIGHT DAMAGE, MNICH SHOULD 8E BROUGHT TO THE ATTENTION OF THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES AND DELIVERING CARRIER. COMPARE TIE CATALOG DESCRIPTION LISTED ON ORDINANCES. PROPER GROUNDING IS REQUIRED TO INSURE PERSONAL THE PACKING SLIP WITH THE FIXTURE LABEL ON THE HOUSING TO ASSURE SAFETY. CAREFULLY OBSERVE GROUNDING PROCEDURE UNDER INSTAL YOU HAVE RECEIVED THE CORRECT MERCHANDISE, LATION SECTION. All ELECTRICAL WORK SHOULD 8E PERFORNED BY A QUALIFIED ELECTRICIAN. WARNING: Make certain power is OFF before starting installation or attempting any maintenance, LOCATE SHIELD ON HOUSE SIDE OF FIXTURE PER FIGURE. THE EDGE OF THE SHIELD SHOULD REST JUST BELOW THE REVEAL. DRILL HOUSING USING SHIELD AS TEMPLATE. INSTALL NINE (9) #10 SCREWS AND NUTS TO SECURE SHIELD TO HOUSING. THESE IISTRUCIIONS DO 101 CU I1 TD COYER All It 1AILS OR VAIIATIDIS II THE EQUIPMENT, PROCEDURE, OR PROCESS DESC11BE1, 101 10 PROYIIt IIRECf1115 FOR 01111 IS EVERY POSSIILI 0111ICINCY OUR; It IISTRLhT111. OPERATION COOPER Lighting, Inc. FIR 'S YOURIIEARESIIREPUSENIATI}ESFr A PROBLEM 101 COYER[B SUFFICIENiIY JEU 06/22/00 IMI -428 REV. 2 VLO -906 PAGE 1 TAB 12 EF -01 CS -01 BL -03 I�ro�er CB-01 CB-01 j SOLDIER COURSE enlarged partial elevation Kroger J904 November 25, 2009 Carmel, IN 509031 c a hAk architecture a e s g n MATERIALS AS -01 Aluminum Storefront Aged Bronze BL -03 Rockface Shouldice Chamois CB -01 Cast Brick CS -01 Cast Stone Limestone EF -01 EIFS Parchment EF -02 EIFS Champagne FA -01 Fabric Awning MC -01 Metal Coping Aged Bronze MD -01 Metal Downspout Aged Bronze MS -01 Metal Scuppers Aged Bronze PT-06 Paint Fairfax Brown material key Kroger J904 rti• R November 25, 2009 Carmel, IN 509031 architecture design CARMEL GREEN BUILDINGIRENOVATION CHECKLIST These items are not required by the current Zoning Ordinance or Building Code, but are strongly recommended by the Department of Community Services. Green building and design saves energy and money while providing for a more sustainable community. NEW CONSTRUCTION Bicycle lockers /changing rooms /showers Bicycle racks will be provided ®Best Management Practices for stormwater ®Native landscaping /tree preservation ®Connectivity to adjacent sites ❑Green roof ❑White membrane roof ®Porous pavers in parking lot ®Recycling areas onsite ®Parking islands landscaped to provide shade within 5 years ®High- efficiency lighting inside and outside LEDs in the GD cases with motion detectors. LEDs in the walk -in freezers LEDs used on exterior signage ❑Building materials sourced from within 500 miles ®Water- efficient fixtures water closets ❑Use of recycled materials in construction and fit -out ❑Operable windows for cross ventilation and light ®High- efficiency HVAC systems Environmental panel for HVAC ®Use of Energy Star Building Energy Star Certification ❑Low VOC paints, coatings, and sealants ®Low -E glass ❑Low VOC flooring materials ®Light and motion sensors for lighting ®Skylights to harvest natural light Sales Floor lighting is configured to turn off in stages depending on the amount of light available through the skylights Heat reclaim is used as part of the water heating, building heat and humidity control M cR JRE COURSE r dumpster enclosure Kroger J904 November 25, 2009 Carmel, IN 509031 A architecture hk 20' -0" CS -01 CB-01, SOLDIER COURSE CB-01 CONCRETE CURB cart corral Kroger J904 wlr o November 25, 2009 Carmel, IN Ik 509031 architecture a e s i g n PRECAST CONCRETE BOLLARD bollards Kroger J904 it kA it 10, 2009 Carmel, IN 509031 architecture design B -5 ZONING BLACKSTONE GROUP -DIT LLC yP INSTR. 03 SECONDARY ENTRANCE ONE WAY IN ONLY o D Y ETE ARC I A 1 is, Mechwart, Tombleton Tilton, Inc. leers Surveyors Planners Scientists N. Shadelard Ave., Indianapolis, IN 46250 e: 317.913.6930 Fax: 317- 913.6928 C M X X V II I J Ol X 1 N 2,500 S F o RA U� OUTLOT 1 i 1.314 AC (2,500 SF BUILDING MIN.) N POTENTIAL OUTLOT DEVELOPMENT EXHIBIT KROGER J904 RETAIL CENTER 1 50' 11 -10 -2009 1 of 1 t k k UARD RAIL PP R I, PLC 6838 LC 8 9 73 THE SHOPF�L W ON PO :2 ING li k 1 y f d SCALE: o DRIVE CONNECTION TO 1 =40' WESTON POINTE RETAIL CENTER Date: Evans, Mechwart, Hambleton 8 Tilton, Inc. 11-1 0-2009 Engineers Surveyors Planners Scientists 7400 N. Shadeland Ave.. Indianapolis IN 4625 o SHEET No. Phone: 317.913.6930 Fox: 317- 913.6928 Z KROGER J904 M x X v I RETAIL CENTER 1 of 1 TAB 13 '61p no,( alo)aq �la� VNVIONI '19LNNVO •MO!JG S,�EyM MOUh Z9 L8'BLS'G lE'xd Otl021 NVJIHOIW'N S£ElL Oszsb NJ'sllodeueipul b31N33 11tl138ou,9�a�4wr anuO lsaM,(emallse00969 U- 6 Z 0 406r a39OVX A M uedwo��a6o�H a41 V rroo lamas �a�e wmaa w o. f a SNtlld NOI2f1d1SN00 b PR• d O Cs sg'€ a fi a as s up ss f U h U e s adsooe ads e a w wa s a 3 m s m w W O w w z ugn =w j S B 3 8.A8 t ile 5z3AA 5. Pi wow q,— -W. H S. M. A �mm ei. NP qa B� .a mad €wa=s° <a cc u `0�-. 2� LLI (J Jog Q 0444 LU u `0�-. 2� C f J b nob ajo '61 VNVIdNI'-3WNVO P MO0 �s�,7e'ym�ouN Z%g 6LS L6£.xj Q OVOt NVOIHOIW'N9CM y £9b£ 6L 'S L6E 4d r y OSZ94 NI spodeueipq V31N33 lIV13H o r anup �saM 6eMa��seO 0965 g06P N3JON)1 o ,Cuedwa� ia6wN a41 y f P 1 N vxanrva� m3inx mi �a msuv� ao-cri i eon f Mom srvoisinsn .eoaaaeva3w 9Ntlld N011OfIN19NOO :aasevaaea n s v s e a a f s w �Us TITF 2 c c m`a'ma W aa sE° -'b e 1 Ron a IN j a §El T j t4llt, u z 1 0 00000® S 5� -,a. y to r n y. rte. r a S M� M, ig L f t x o a ass Nag �w a1 H oe aos s s' a z o g a 3� lis m, NA a se b w •6lp nob ago ;aq ���3 'mob snum mouN q Z9t8'6LS LlE .xj E94E'6GS'LGE 4d 09Z94 NI s6odeuelpul onu01?aM 09a9 Ruedwop $a6ar ayl VNVIONI 'lAAdVO ovoa NVOwoiw Seen. 113IN33 IMUM 106r v 3so21m SNtlld NOIlOfta1SN00 °N as rc, y Z o� o P lu is I m r' a o a I a a w w W q A F W a I W f s Ad ms q o Y a o 0 0 It1 Vi i. 0 a g x P e 8 8 d b w lu is Y 8 $eo s Z S gs 2 Ul a W 51p noA wcqaq lleo VNVlGNl'laVWV0 tAolaq SA MOUN Z9 L 9 6) 9 z I c -j 0 N Seeu c, 09W6L9*LL6 :qd 0. OMCIA N e!m 1l31N3:) '11VJ.3H qj V06r Haoomm MEMO SNbld Nouon-SN00 o 1 I x i!2 0 i... N ID s 3 5 A� A R H, H P: S N 0 5. z .0 m I e g z A S 8' w Wl�� 1 0 5 r N �5 1 W 2 T T A- r la" N g H Z H -a� -.JD k COP -Z wo C- z A H,ez�� z o kz A\ y C) 0 Y (D C) z 0 Z =z LU E Na Z Noo�rA3a�uv '61p n0,(al0q ��C'J 'MO 9dzgm MOUp 1 Z9L8'6LS'LLS �4d :xd E9486LS'LlE O9Z94 NIspOd 'Pul anu0 -M 9965 Ruedwo� �a6aN ayl tlNVIdNI'l3WaV� CVOa Ntl`JIHJIW'N 9EE L L H31N3a 11V1311 b06r N390MI4 sNVtd NouanaisNOo r zz= g S o N�1 V 9 1 ow pp 33 �y ®4 o mLL �o 0 l zg "AAA vv� �i��vVv 0 Mm ir w 8 o y V V J 2 l s I Noo�rA3a�uv r ar.RO JIB I o 9 1 ow pp 33 �y ®4 o mLL �o 0 l zg "AAA vv� �i��vVv 0 Mm ir w 8 o y V V J 2 l s I 4 g Q Z Q s� o s k= AA V A 6F �a G l 1 CD ���v y I co w� a z A pLL s9 J C 8 s e ss e a a E� a e a f s a HO s M H 8� Al s H, P R Hp ow =a o a s H i H g 6 M a m. F a l H P °N 'ms 6� no,( p'M0l8q }s,6jegm�ouN VNVIGNI'13waV0 a �N Z8 L8'6L9'LtE xj E9h8'61.9 LLE4d NtlOb Ntl•JIHHIW'NSEE4L O9Z94 NI s lodeuepul Ruedwo� a6oi�a4t U31N39 1 V.L3�1 4o6P asooLN SIN NO\lONN1SNOO v r oaaCz 'o5zfi a'�` Q. ,h bg 4 g Q Z Q s� o s k= AA V A 6F �a G l 1 CD ���v y I co w� a z A pLL s9 J C 8 s e ss e a a E� a e a f s a HO s M H 8� Al s H, P R Hp ow =a o a s H i H g 6 M a m. F a l H P °N 'ms 'UlpnoAa�o)99"g3 VNVIONI'ISAUVO Z9L8'BL5 L IC :xd 'l ko�8ys•{eymmouN �Y 6949.015LLSyd NtlOilNtlJIH�IW'N SEEL4. F Z g g M 05Z9bN1 slodeuetpul M31N3D 1IV13�1 a a a 'Za0 aRM 0965 S ati 2 S o- z Q U u, a 6uedw �a6o��{ ayl ti06P L3'JON)i. vwrvrvm ww �a� ec os f SNO S�sa SNYI NOUMU1SNOO �14 Ml Wa no ava3aexe aveaae W1•V• �€6$CZ ZOZS'yd �sN�� `a e 88 k'o V aW r U y f w I x LL& 4 Y 4 9 2 1 T e ME lz r HE 5. shy 1 ro $h 8 4 m as e s i Om N m d O b l Z Q Km 0 m C�g°W A O I 0 m �I 0 �NZ ��m O z �m o oY a e ME lz r HE 5. shy 1 ro $h 8 4 m as e s •hip nob aio)eq Ilg� 'M00 sleym mouN 1 q ZSlB'6LS'L6E :xj £918611'11£. :4d OSZ9t NI syOdeuelpul nuQ }saM,(emallse0 6965 bNVIONI '"13W?Jtl0 avoa NVOiNOiw'N Seeu N31N3'J 1IV13M voer a39oam aoa SN— NO 10n-SNOO N,,, o Z o ny'"ub PR m ntaory o enia s33ai3avns xo 1 a 9� 3fanea 3au io maze J� IN w�� O Nob a c a s' b J( o \\A\ ax e� \'1 O F c��N +a 550UF NSP` /z .�q ORN 50E ER x 3 I w Z J H I N U44Y�. x x x u a i xauvs 30 Sin amz 6i nod awo p )s,wgmma mo�aq le4 N1 zs I8 6L9 LIE :x= EM? 6L9 LIE :4d OSZ9b NI s.Iodeuepul a ..d..o .B lae� R 0q uedwo� I ayl VNVION113INUVO Ntl�JIH� N �131N3�'11tl13Z1 406P m3'J0m2i sNVIa NouanaisNOO may .a3�a" a a a a m I I b O In m 0 XX of J o \V, 'III N m q-p^ d r o Ix I p w J p¢ Z _j W1 cc Z m w -mojoqswqmmou)I 0 Z:9[8 US LlC:X=I C9 96L2 I LE :qd 95Z9b I s ilodeuepul A­d GVO� N�IHCIN *N M I I H31N33 lIV13H IP06f U300mm S­dNOixomISN00 E 2 E z C4 N wa. 0 O Z _j W1 cc Z m w z :52 N wa. 0 O T K MH p 29 M M -M, t i H M Hd mss 'IM g., -N H Z _j W1 cc Z m w z :52 Z W1 wa. O TAB 14 DECLARATION OF COMMITMENTS IS DECLARATION, made this Y�- 38, by Robert Carter Altum (h eereinafter to as I Joseph C. Miller and Margaret M. Miller (hereinafter referred as Sellers), WITNESSETH: WHEREAS, Joseph C. Miller and Margaret M. Miller are the Owners and Contract Sellers of all of the real estate described in Exhibit "A", attached hereto and made a part hereof; and WHEREAS, Robert Carter Altum is the Contract Purchaser of all the real estate described in Exhibit "A", attached hereto and made a part hereof, and is the Owner of Altum Gardens, a garden shop, landscape contracting, and ,plant nursery business, to be established on said real estate (hereinafter known as the Property); and WHEREAS, the Buyer and Sellers art seeking a change in the. Property's zoning classification, from S -1 to 3-3, and desire to impose upon the property certain conditions and restrictions (hereinafter referred to as Restrictions) that will enhance the stability of local land use patterns and provide for the orderly and attractive future development of the Property, for the surrounding community and future owners thereof; NOW, THEREFORE, the Buyer and Sellers hereby declare that all the Property as it is held and shall be held, conveyed, hypothe- cated or encumbered, leased, rented, used, o'r- occupied and improved, is subject to the following Restrictions. All of the Restrictions shall run with the land and shall be binding upon the Buyer, his heirs and assigns, and all parties having an interest in and to the real property or any part or parts thereof subject to such Restrictions, and shall inure to the benefit of the Buyer and every one of his successors in title to any real estate in the Property. The Buyer specifically confers the exclusive right or privilege of limiting or dissolving these Restrictions and their future applicability upon the Carmel Plan Commission. I. CERTAIN LAND USES PERMITTED. The following is a list of land uses which, pursuant to zoning classification regulations, shall be permitted as uses of the Property: A. Artificial lake or pond. C Commercial greenhouse. G, Craft and hobby shop (related to outdoor accessories, landscaping, or plant material, both real and arti- ficial). Page 2 Declaration of Commitments D. Garden shop. E. Porch /patio and outdoor furniture store. F. Sales and storage of landscaping and building materials (both enclosed and unenclosed). G. Plant nursery. H. Wholesale or retail sales of goods and services commonly associated with garden shop /nursery /landscaping uses. I. General offices. J. Flower shop. K. Landscape contracting. L. Coffee shop /food service limited to use by patrons of the primary use. All other land uses listed as permitted by the Carmel Zoning_ Ordinance, Ordinance #Z -160, as amended, in the.B -3 district classification are prohibited, unless otherw; se �s peci -f� erJ- b Cai -Mew P j an Cammzssio`n 2. MICHIGAN ROAD /S.R. 421 CORRIDOR OVERLAY ZONE. From the date of recording an ordinance defining the property as B -3 pursuant to Carmel City Ordinance #Z -160, no structure shall be placed on the property, nor shall any site development plan or landscaping be executed without prior Plan Commission review of the develop- ment plan pursuant to the procedures for review as described in said Ordinance #Z -160. The requirement for the review of the Overlay Zone shall continue until the procedure for such review is deleted from Ordinance #Z -160, until such ordinance is repealed, or until the Plan Commission relieves this property of this restriction. b W age Three Ueciaration or Uommltments IN WIT�SS W14EREgF, y r has executed this Instrument, on this (3 day of yG 1988. Robert art�eltum�� STATE OF INDIANA SS: COUNTY OF HAMILTON SUBSCRIBED AND SWORN t me, a Notary u Ic In and for said County and State, this day of 5 1988. oY'► Printed: lit• �.qs� C�✓�;r,,� Lie Notary Public Resident of County My Commission Expires: oll U IN WITNESSaWHEREOF, Selle lave executed this Instrument, on t h i s YY� day of f� 1988. i )Jos ph C. M11 ler��` margeVet M. Miller STATE OF INDIANA COUNTY OF SS: HAMILTON SUBSCRIBED AND SWORN to me, a NotarY In and for said County and State, this L2 9 day 0 f 1988. My Commission Expires: 2— Printed: LAX A sn.... (,J Notary Public Resident of J75�� County C This document prepared by William E. Wendling, Attorney At SEP /30 /2008 /TUE 01;33 PM Altum's Horticulture FAX No.3177334747 P,Q02 09/00/2008 10,16 FAX SHAM BUS. BANKING W002 9VAMOOa 11;10 PAZ 4WORAMno MO 10ous N iie N ral xe�x�aea A�at7 n!'1�'om'uyYvapoly7'oa ft1bNIA DART OF Miw�T Qu"= or �Tx0�7 6, TOXMWP 3.7 M' B4Ei�8� As PoL&= D 12 r M3x Lru ow TM Mwmansw pt�,$ ov �s�rxro�r P 3,7 M, 3 MOT 106 F=r 89 2S S� WM Gtr gM Vp4M TSM "r T53sM 00 a 410 45 T 1 'fig MM L M or 5 Ssa 0s aa POIRM 1037 04 80 3 00 ¢g 45 ao�ns cam or sAm BOVM as 29 �a 2s dft"w WNT PAnim %I= V 40 754.46 f as t n DRMRM WM z�.sv 'rr 90t= 7S yam S Y add ti�� 848.00 MT 70 TM qW 4Ut TMCM MUM 3.4 t t6S.4 $Z XFM F u n m �"M 6 yy v] T Mo T= 8 2 5 =00 BMW C �NCS SMM 89 6 29 TI M OM 3� A SA SDUS- �,=g 1208.85 VEW To 7MCsPT TMLT FART' DEEM Tipp TER TJR M MMMU Mfg nmViown Hum an 2000000,9125, MCEIDD A$ VOLLMS, A PA= ON M x QMU=a Ckv BXLV M 6, GYP 17 3 Y OF Tex PARY OF 2= 0 1 T3M L Tim =am or tld= Lm Ov 32 AS =v:t l3�t oAi TA O s e R dF My PAU= T Mso ftaftnM as OUT H W OLM O S Y 'JiRfB'�,' G73.76a �50 B R 80U= "In Of 8= MRMM SEA TQ 'r= Rft"Aw er a E 16 40 o ms Og6CR1P703, (646.45 M sd 20 i ov g V. 7.a37 KMT IIMTR LIM OF MW 1 k1CiD�5* O� gl4,rp Q 421 '�0 �$B 3 v B ram,, TS 2 T 26 3 Sj3 S sAft a 76 6 1+ ,*gRT BM Ws 1 dR' Ltd r Bdt7 ,1t Is bRMW 48 MMM 30 M BABY s5, R23 MWIMW (3X4_38 BA a�a 7'H+1° as dON IL 11r1 T pY M,'� Fib Val 1.'1 B 30 [y n7 MS S- &EMIDS 3 4t).= pgrM(231.60 7 P OMT tt 93ZLJW PLAT; S 75 ttasims 46 Nnomw 01, S W-ST 42 .807 Mrs= (204.35 Pte`) To r= SOLD L3�jg $8 O&M 1hS.r 2.192.197 D 39 M7JW S 09 TM POINT OR 9.43 87#8'x3 XMTR 8 �+0� SAM 190U S L fi'o` win .A GR Iii„ Mw 0.089 (01223. room 2W4 M-to w ON 09 00 9LUTC spa ww =90 8002 /09 /60 TAB 15 COMMITMENTS CONCERNING USE AND DEVELOPMENT OF REAL ESTATE Kroger Limited Partnership I, an Ohio limited partnership, "Kroger and 1031 Z B, LLC an Indiana limited liability company "Z B make the following commitments (the "Commitments to the Plan Commission (the "Plan Commission of the City of Carmel, Indiana (the "City Section 1 Cross Reference These Commitments are made in connection with the approval by the Plan Commission of DP /ADLS on under Docket No. 09100009 (the "Approval with respect to the real estate described in what is attached hereto and incorporated herein by reference as Exhibit "A" (the "Real Estate Section 2 Definitions The following definitions shall apply throughout these Commitments. A. "Landscape Plans" shall mean the final Landscape Plans approved as part of the Approvals. B. "Sanitary Lateral Plans" shall mean the plans that are attached hereto and incorporated herein by reference as Exhibit "B" C. "Sanitary Lateral" shall mean the sanitary lateral identified on the Sanitary Plans. Section 3 Commitment Concerning Only the following uses, individually or in any combination, are permitted uses upon the Real Estate. A. Clinic or Medical Health Center; B. General Office; C. Professional Office; D. School, Trade or Business; E. Day Nursery /Day Care; F. Kindergarten /Preschool; G. General Retail Sales (including, without limitation, grocery Store and pharmacy with or without drive -thru service); H. General Service; I. Automobile Fuel Station; J. Automobile /Truck Repair (indoor); K. Car Wash; L. Dry Cleaning Establishment (with or without on -site plant); M. Financial Institution; N. Automated Teller Machine (ATM); O. Veterinary Hospital (with or without commercial kennel) P. Art gallery; Q. Restaurant (with or without drive thru service); R. Printing /Publishing Establishment; S. Accessory Outdoor Sales in area designated on approved plans; and T. All uses accessory to the foregoing permitted uses. 1 of 5 Section 4 Commitment concerning traffic Trash pick -up and delivery of food, inventory and goods shall not be permitted between the hours of 12:00 a.m. and 5:00 a.m. Section 4 Commitment concerning landscape buffering. Landscape buffering, including mounds and fences shall be installed per the Landscape Plans. Section 5 Commitment concerning sanitary sewer. Kroger shall extend Sanitary Lateral, per the Sanitary Plans, subject (i) to final approval of the Sanitary Lateral by the Clay Township Regional Waste District and (ii) to the acquisition of the easement necessary to install the Sanitary Lateral. Section 6. Recording of Commitments The undersigned shall record these Commitments with the Recorder of Hamilton County, Indiana. Section 7 Enforcement These Commitments may be enforced by the Plan Commission. Section 8 Binding on Successors These Commitments are binding upon Kroger and Z B and their successors, assigns and grantees, unless modified or terminated by the Plan Commission after a public hearing wherein notice is provided by the rules of the Plan Commission. The provisions of this Section 7 notwithstanding, these Commitments shall terminate as to any part or parts of the Real Estate hereafter reclassified "Rezone on the City's official Zone Map. Section 9 Effective Date These Commitments shall not be effective or enforceable until the commencement of the construction and development of the Real Estate in accordance with the Approval. IN WITNESS WHEREOF, Kroger has caused these Commitments to be executed as of the date identified on the Notary below. Kroger Limited Partnership I, an Ohio limited partnership By KRGP, Inc., an Ohio corporation, general partner Un STATE OF INDIANA SS: COUNTY OF Before me, the undersigned, Notary personally appeared the partner of the Kroger Limited Partnership I, Commitments and on behalf of such entity. Witness my hand and Notarial Seal this Public in and for the said County and State, of the KRGP, Inc., as general who acknowledged execution of the foregoing 2of5 day of 2010. My Commission Expires: Notary Public 1031 Z B, LLC, an Indiana limited liability company an STATE OF INDIANA SS: COUNTY OF Before me, the undersigned, Notary Public in and for the said County and State, personally appeared of 1031 Z B, LLC, who acknowledged execution of the foregoing Commitments and on behalf of such entity. Witness my hand and Notarial Seal this day of 2010. My Commission Expires: Notary Public Prepared by: Charles D. Frankenberger, Nelson Frankenberger, 3105 E. 98 Street, Suite 170, Indianapolis, IN 46280 (317) 844 -0106. Pursuant to IC 36- 2- 11- 15(b)(c), I affirm under the penalties for perjury, that I have taken reasonable care to redact each Social Security number in this document, unless required by law Charles D. Frankenberger. H:\Beckffoning Real Estate Matters\Zinkan Barker \Cannel- MichigmRd \COMMITMENT 2.doc 3 of 5 EXHIBIT "A" Legal Description PART OF THE NORTHWEST QUARTER OF SECTION 6, TOWNSHIP 17 NORTH, RANGE 3 EAST IN HAMILTON COUNTY, INDIANA, MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING ON THE SOUTH LINE OF THE NORTHWEST QUARTER OF SECTION 6, TOWNSHIP 17 NORTH, RANGE 3 EAST 1050.72 FEET NORTH 89 DEGREES 34 MINUTES 50 SECONDS WEST FROM THE SOUTHEAST CORNER THEREOF; THENCE NORTH 00 DEGREES 09 MINUTES 33 SECONDS EAST PARALLEL WITH THE EAST LINE OF SAID QUARTER 814.81 FEET TO A POINT 1839.73 FEET (1837.04 FEET DEED) SOUTH 00 DEGREES 09 MINUTES 33 SECONDS WEST OF THE NORTH LINE OF SAID NORTHWEST QUARTER; THENCE NORTH 89 DEGREES 34 MINUTES 49 SECONDS WEST PARALLEL WITH THE SOUTH LINE AFORESAID 753.62 FEET (754.46 FEET DEED); THENCE SOUTH 07 DEGREES 53 MINUTES 26 SECONDS WEST 11.60 FEET; THENCE SOUTH 72 DEGREES 06 MINUTES 26 SECONDS WEST 578.5 FEET TO THE EAST RIGHT OF WAY LINE OF U.S. HIGHWAY NUMBER 421 PER INDOT PLANS PROJECT #STP- 135- 2(008); THENCE SOUTH 15 DEGREES 21 MINUTES 16 SECONDS EAST ON AND ALONG SAID RIGHT OF WAY LINE 311.29 FEET; THENCE CONTINUING ALONG SAID RIGHT OF WAY LINE, SOUTH 11 DEGREES 03 MINUTES 55 SECONDS EAST 131.60 FEET; THENCE CONTINUING ALONG SAID RIGHT OF WAY LINE, SOUTH 15 DEGREES 21 MINUTES 16 SECONDS EAST 206.37 FEET TO THE SOUTH LINE OF SAID QUARTER; THENCE SOUTH 89 DEGREES 34 MINUTES 50 SECONDS EAST ON AND ALONG SAID SOUTH LINE 1146.02 FEET TO THE BEGINNING POINT, CONTAINING 22.022 ACRES, MORE OR LESS. 4of5 EXHIBIT "B" Location of sanitary sewer EMHT to provide 5of5 HABecky\Zoning Real Estate Matters\Zinkm Barker \Carmel- MichigatiMCOMMITMEW 3.doc