HomeMy WebLinkAboutUntitled (51)Project:
Sheet Number:
Carmel, Indiana 46032
317.705.7980 (fax)
355 City Center Drive
317.705.7979 (phone)
Architect:
Sheet Title:
VILLAGE ON THE GREEN, PARCEL 7C-2
Carmel, IN, 46032
COPYRIGHT & OWNERSHIP OF DOCUMENTS
Architecture / Project Management:
Project Number:
Last Revision Date:
Print Date
Drawn By Checked By
Sheet Issue Date
OFFICE BUILDING & BLACK BOX THEATER
PEDCOR DESIGN GROUP
AG001
GENERAL
ARCHITECTURAL
!"#$%&’()*+,!%#$%-,%#,$!.)*+,!%’/%$+.0#(+$%-,&%#$%!"+%$’1+%2.’2+.!3
’/%!"+%-.("#!+(!%-,&%2+&(’.%&+$#4,%4.’)25%11(6%%-11%#,/’.*-!#’,
(’,!-#,+&%"+.+#,%#$%(’,/#&+,!#-16%%#!$%$)7*#$$#’,%-,&%&#$!.#7)!#’,%!’
’!"+.%2-.!#+$%#$%,’!%!’%7+%(’,$!.)+&%-$%2)71#(-!#’,%#,%&+.’4-!#’,
’/%(’**’,%1-8%(’23.#4"!5%#,!+11+(!)-1%2.’2+.!3%.#4"!$%’.%’!"+.
.+$+.0+&%.#4"!$6%%-11%#,/’.*-!#’,%(’,!-#,+&%"+.+#,%(’,$!#!)!+$%!"+
’.#4#,-1%-,&%),2)71#$"+&%8’.9%’/%!"+%-.("#!+(!5%:-*+$%.6%$!)!;*-,5
-,&%2+&(’.%&+$#4,%4.’)25%11(6%%,’%2-.!%’.%8"’1+%’/%!"#$%&+$#4,5
!"+$+%&.-8#,4$5%’.%!"+%.+$)1!#,4%7)#1&#,4%’.%7)#1&#,4$5%’.%2’.!#’,$
’/%!"+%.+$)1!#,4%7)#1&#,4%’.%7)#1&#,4$%*-3%7+%&)21#(-!+&5%(’2#+&5
+<"#7#!+&5%2"’!’4.-2"+&5%2)71#$"+&5%*’&#/#+&%’.%’!"+.8#$+
&#$!.#7)!+&%#,%-,3%8-3%8#!"’)!%!"+%$2+(#/#(%-,&%2.#’.%8.#!!+,
(’,$+,!%’/%!"+%-.("#!+(!5%:-*+$%.6%$!)!;*-,%-,&%2+&(’.%&+$#4,
4.’)25%11(6%%=%%(’23.#4"!%>??@5%>??A5%>??B5%>??C5%:-*+$%.6%$!)!;*-,5
-#-5%(-.*+15%#,6
BID SET No.1
SHELL & CORE
ejd,jls LGA
10/2/09
30 West Main Street, Suite 220
Carmel, Indiana 46032
317.571-2787
CARMEL CITY CENTER
COMMUNITY DEVELOPMENT
CORPORATION
!"#$%&
North
Parcel 7-C Keyplan
7C-1
7C-2
7C-3
9/15/09
1. ADDENDUM NO. 1 10-02-09
7 1/4" 6 5/8"
8 5/8" 9 1/4"
3 5/8" 4 1/4" 4 7/8" 6 5/8" 6" 6 5/8" 7 1/4"
6 5/8" 8 5/8" 11 1/2"
4 1/4"
7 1/4"
7 5/8" 9 3/4"
1 1/2"
1 1/2"
9 1/4" 8 5/8"
3 5/8" 5 5/8"
BOT. OF DECK (U.N.O.)
6" METAL STUD
5/8" GYP. BD.
6" METAL STUD
5/8" GYP. BD.
8" METAL STUD
5/8" GYP. BD.
8" THERMAL INSUL.
5/8" EXT. SHEATHING
8" METAL STUD
5/8" EXT. SHEATHING
8" THERMAL INSUL.
BOT. OF DECK (U.N.O.)
3 5/8" METAL STUD
5/8" GYP. BD.
3 5/8" METAL STUD
5/8" GYP. BD.
S3A
3 5/8" METAL STUD
8" METAL STUD
5/8" GYP. BD.
8" THERMAL INSUL.
1 5/8" METAL STUD
5/8" EXT. SHEATHING
6" METAL STUD
5/8" EXT. SHEATHING
6" THERMAL INSUL.
6" METAL STUD
5/8" GYP. BD.
6" THERMAL INSUL.
5/8" EXT. SHEATHING
6" CH MTL. SHAFT
WALL STUD @ 24" O.C.
1 LAYER 5/8" GYP. BD. (1 HR.)
2 LAYERS 5/8" GYP. BD. (2 HR.)
6" THERMAL INSUL.
S3 S3B S6CH S6A S6B S6C S6D
S8A S8B S8C
6" SOUND
ATTENUATION INSUL.
1" SHAFT LINER VAPOR BARRIER
- 1 HOUR
6" METAL STUD
S6
VAPOR BARRIER
VAPOR BARRIER
VAPOR BARRIER
VAPOR BARRIER VAPOR BARRIER
8" METAL STUD
5/8" EXT. SHEATHING
S8
VAPOR BARRIER
6" METAL STUD
5/8" GYP. BD.
S6E
6" SOUND
ATTENUATION INSUL.
3 5/8" METAL STUD
5/8" GYP. BD.
S3D
- 2 HOUR
6" METAL STUD
5/8" GYP. BD.
6" THERMAL INSUL.
5/8" GYP. BD.
S6F
VAPOR BARRIER
8" CMU
8" CMU
1 1/2" MTL. FURRING
5/8" GYP. BD.
BOT. OF DECK (U.N.O.)
M8 M8A
CLEAR
CLEAR
8" METAL STUD
5/8" GYP. BD.
8" THERMAL INSUL.
5/8" GYP. BD.
S8D
VAPOR BARRIER
8" METAL STUD
5/8" GYP. BD.
8" THERMAL INSUL.
S8E
VAPOR BARRIER
6" CMU
M6
4" CMU
M4
J-TRACK AT PERIMETER - TYP.
1" GYPSUM SHAFTLINER
PANEL WITH MOLD MOISTURE
& MOLD-RESISTANT CORE
AND COATED GLASS-MAT
FACINGS
PARTITION GENERAL NOTES
A. PROVIDE WATER RESISTANT GWB IN ALL ROOMS
CONTAINING OPERABLE PLUMBING FIXTURES AND
WITHIN 4 FEET OF DRINKING FOUNTAINS/WATER
COOLERS, U.N.O.
B. PARTITIONS INDICATED TO EXTEND UP TO THE BOTTOM
OF THE DECK SHALL BE PLACED AROUND THE
STRUCTURAL BEAMS SO AS TO FORM A SOLID
ACOUSTICAL BARRIER FROM ONE SIDE OF THE WALL TO
THE OTHER SIDE OF THE WALL.
C. SEE THE ROOM FINISH DRAWINGS FOR ADDITIONAL WALL
INFORMATION AND FOR MATERIAL TO BE APPLIED OVER
THE WALL CONSTRUCTIONS INDICATED (EXAMPLE:
CERAMIC TILE, WALL BASE)
D. PROVIDE FIRE SAFING AT ALL BREAKS IN RATED WALLS,
AND IN MTL. DECKING FLUTES AT TOP.
E. SEE FLOOR PLANS, WALL SECTIONS AND INTERIOR
ELEVATIONS FOR ADDITIONAL WALL INFORMATION.
F. WHERE AN AIR SPACE IS REQUIRED FOR EXTERIOR
WALLS, THE AIR SPACE SHALL BE HELD FREE AND CLEAR
OF MORTAR AND CONSTRUCTION DEBRIS.
G. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH
EXTEND PAST CLG. HEIGHT.
H. ALL METAL STUDS AND FURRING IS 16" O.C. UNLESS
NOTED OTHERWISE.
J. ALL EXTERIOR SHEATHING TO INCLUDE A LIQUID APPLIED
VAPOR PERMEABLE AIR BARRIER SYSTEM. REFER TO
EIFS SPECIFICATION 072413 FOR EIFS SYSTEM
REQUIREMENTS RELATIVE TO INSTALLER / WARRANTY.
SCALE: 3/4" = 1'-0"
1 WALL TYPES
AG001 0 1' 2' 3'
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 1
1 1
1
1 GENERAL REVISIONS THROUGHOUT SHEET
1