Concept 09/16/09 2009 ARCHITECTURAL SOLUTIONS, C LTD. Not Published, All rights reserved SOLUTIONS, LTD. Not published, c 2009 ARCHITECTURAL All rights reserved. WILLIAMS BRADLEY D.
TONY SACCO'S PIZZA CLAY TERRACE #4698 SPACE #C13 CARMEL, IN 46032 REGISTRATION NO. 3436 COA-A-10,657 ME Permit 10/30/09 MECHANICAL Concept Approved 09/21/09 Load Calculation Summary
Project: Clay Terrace Date: ###### Revision: Tenant Name: Saccos Coal Fired Pizza Space: C-13 Calculation: Cooling Zone Name: C-14 Sq. Ft.: 3300 Heat Occ. Unit Designation: AHU-1 , AHU-2
Level: Heat Un. (Complete separate form for each zone or terminal device) Design Conditions Outside: Inside: Supply Air Temp: Time: 88 DB 75 DB 55 DB 74 WB 50%rh WB WB Internal Sensible
Total Latent Total Occupant Density: 33 Sq. Ft./Person Space Sensible No. of Occupants: 100 Factor: 250 S 200 L 25000 25000 20000 20000 Lighting Lamp Special No. Total Type: Watts: Allowance
of Watts: Factor: Fixtures EX 150 0 28 4200 A 96 0 11 1056 B 20 0 20 400 D 75 0 7 525 E 75 0 23 1725 F 60 0 8 480 G 75 0 4 300 H 50 0 10 500 J 20 0 2 40 K 40 0 2 80 L 20 0 2 40 Q 10
0 7 70 R 40 0 5 200 Neon Lin. Ft.: 0 BTUH /Ft.: 0 Subtotal Lighting 9616 24554 32819 Thermal Exhaust Credit (Food Court Only) CFM x 1.085 x Acceptable Temperature Rise External Exp.
U or R /S.C. Factor Area Glass south /44.8 724 32435 32435 west /44.8 345 15456 15456 //Horiz. /Wall 6.42 1323 8494 8494 5.86 472 2766 Floor Partition Roof 4.17 3300 13761 22638 Subtotal
Skin Loads 70146 73295 Outside Air No. of Occupants: 100 CFM per Occupant: ASHRAE 62.1-2004 Total CFM: 1440 20311 41249 Subtotal External Loads (Skin, Outside Air) 90457 93606 Subtotal
Internal Loads (Occupant, Lights, Misc., Ex. Credit) 49554 49554 TOTAL 140011 151425 61249 212674 TSF1a -Load Calclt'n Summary Mechanical System Summary (Rooftop or Split System) Project:
Clay Terrace Date: Revision: Tenant Name: Saccos Coal Fired Pizza Space: C-13 Rev. Date: Level: Sq. Ft. 3300 HVAC Total Load: 212674 Space Sensible Sq. Ft. Per Ton: 220 Load: 140,011
Btuh Per Sq. Ft. Sensible Load: 151425 Latent Load: 61249 Total Supply CFM: 7000 Supply Air Temp: 55 CFM Per Sq. Ft. 2.1 Glass Sensible Latent Total Cooling Load Glass (Hor.) 47891 47891
Component Totals Wall 11260 11260 (All Zones) Floor Partition Roof 22638 22638 Occupant 25000 20000 45000 Lighting 32819 32819 Misc. Process Equipment 30000 30000 Outside Air 20311 41249
61560 Heat Loss Occupied 202072 Unoccupied 73048 Air Balance Process Exhaust Cfm 0 Min. Outside Air Cfm 1440 Kitchen Exhaust Cfm 1300 Economizer Cfm 0 Toilet Exhaust Cfm 300 Replacement
Air Cfm Thermal Exhaust Cfm (Transfer from Total Exhaust Cfm 1600 Common Area) 1440 Makeup Air Unit CFM 1440 Relief @min. O.A. Pressure min. O.A. -160 Relief @Economizer Pressure Economizer
Plumbing Domestic Water Fixture Units 68 Demand 35 gpm Min. Size Req. 1-1/2" Domestic Water Heater Size 100 gal Input Rating 199.0 cfh Meter Sanitary Fixture Unit 85 Min. Size Req. 4"
Vent 85 Min. Size Req. 4" Grease Waste Interceptor Size 35 gpm Gal. 70 Lbs. Location dish washer Waste Fixture Units 35 gpm Min. Size Req. 3" Vent Fixture Units 35 gpm Min. Size Req.
3" Natural Gas HVAC CFH 0 Length of Run Makeup Air CFH 0 from Meter 75' Equipment CFH 225 Pressure 2.0 psi Dom. Water CFH 199 Min. Line Size 1-1/4" Total CFH 424 Regulator yes Length
of Run 75' Appliance Pressur 7-14" Min. Line Size 1-1/4" Meter Location verify Service Type Direct Utility Billed ? Landlord Redistribution TSF2U -Mech System Summary M3.0
Concept 09/16/09 2009 ARCHITECTURAL SOLUTIONS, C LTD. Not Published, All rights reserved SOLUTIONS, LTD. Not published, c 2009 ARCHITECTURAL All rights reserved. WILLIAMS BRADLEY D.
TONY SACCO'S PIZZA CLAY TERRACE #4698 SPACE #C13 CARMEL, IN 46032 REGISTRATION NO. 3436 COA-A-10,657 ME Permit 10/30/09 MECHANICAL Concept Approved 09/21/09 M3.1 Design Air Balance Summary
Project: Clay Terrace Date: Revision: Tenant Name: Saccos Coal FireSaccos Coa Space: C-13 Rev. Date: Level: Sq. Ft.: 3300 HVAC Units at Minimum Outside Air Device Supply Outside Return
Barometric Powered Exhaust Replacement Pressure CFM Air CFM CFM Relief Relief CFM CFM CFM CFM CFM 1. AHU-1 3500 720 2780 2. AHUAHU-2 3500 720 2780 3. EF-1 150 4. EF-2 150 5. Kitchen
Hood-700 6. Makeup Air Unit-7 Kitchen Hood-8. Makeup Air Unit-9. Dishwasher Hood 600 10. Toilet Exhaust see above 11. Trash Exhaust 12. Relief Fan TOTAL 7000 1440 5560 1600 -160 Replacement
Air from Transfer Fan the Common Area Gravity 1440 Total HVAC Units at Economizer Device Supply Outside Return Barometric Powered Exhaust Replacement Pressure CFM Air CFM CFM Relief
Relief CFM CFM CFM CFM CFM 1. N/A 2. 3. 4. 5. Kitchen Hood-6. Makeup Air Unit-7 Kitchen Hood-8. Makeup Air Unit-9. Dishwasher Hood 10. Toilet Exhaust 11. Trash Exhaust 12. Relief Fan
TOTAL Replacement Air from Transfer Fan the Common Area Gravity Total TSF3 -Design Air Bal Summary
Concept 09/16/09 2009 ARCHITECTURAL SOLUTIONS, C LTD. Not Published, All rights reserved SOLUTIONS, LTD. Not published, c 2009 ARCHITECTURAL All rights reserved. WILLIAMS BRADLEY D.
TONY SACCO'S PIZZA CLAY TERRACE #4698 SPACE #C13 CARMEL, IN 46032 REGISTRATION NO. 3436 COA-A-10,657 ME Permit 10/30/09 ELECTRICAL Concept Approved 09/21/09 TONY SACCO'S -INDY DATE:
OCTOBER 2009 ELECTRICAL LOAD SUMMARY NEC DEMAND DESCRIPTION KVA AMPS MULTIPLIER KVA AMPS NOTES LIGHTINGRECESSED 6 7.2 1.25 7.5 9 SURFACE 0.5 0.6 1.25 0.63 0.76 TRACK 3.1 3.7 150VA/2FT
6 7.2 SIGN 0.9 1.1 1.25 1.1 1.3 RECEPTACLES 15.2 18.3 1.00 (1ST 10KW) 12.6 15.2 WATER HEATER 0 0 1.00 0 0 AIR HANDLING UNIT FAN MOTOR 2.6 3.1 1.00 2.6 3.1 (2) UNITS ELECTRIC HEAT 46
55.3 1.00 46 55.3 (2) UNITS AIR COOLED COND. UNIT 9 10.8 NON-COINCIDENTAL LOAD 0 0 (2) UNITS MISC. EQUIP. 1 1.2 1.00 1 1.2 25% OF LARGEST MOTOR 2.25 2.7 1.00 2.25 2.7 KITCHEN EQUIPMENT
27.8 33.4 1.00 27.8 33.4TOTAL 114.35 137.4 107.48 129.16 VOLTAGE: 277/480V 3-PHASE 4-WIRE NEC CONNECTED E0.5 ELECTRICAL LOAD SUMMARY CHECKLIST Project: Clay Terrace Date: Tenant Name:
Sacco's Coal Fired Pizza Space: C-13 Zone Name: Sq. Ft.: 3300 Item Voltage Connected Demand Notes KVA KVA Lighting 120 16 20 Receptacles 120 15 12.5 Air Handlers 480 2.6 2.6 Air Conditioning
Units 480 9 0 non-coincidental load Electric Space Heaters 480 46 46 Electric Water Heaters 0 0 0 Miscellaneous Other Loads 120 26 26 kitchen equipment Total Connected Load 480 114.6
0 Design Demand Load 480 0 107.1 Estimated Billing Demand Load -Summer 480 0 70.1 Estimated Billing Demand Load -Winter 480 0 107.6 Time of Day Maximum Demand is Anticipated -Summer
2:00 pm and 6:30 pm Time of Day Maximum Demand is Anticipated -Winter 2:00 pm and 6:30 pm Store Business Hours 9:00 am -10:00 pm Additional Store Hours for Cleaning, Stocking, etc. -A.M.
8:00 am -10:00am Additional Store Hours for Cleaning, Stocking, etc. -P.M. 10:00 pm 1:00am