HomeMy WebLinkAboutAmica Construciotn Drawings pdf binder_Page_0211 17 1 1 li 1 1 s 14 15 1b IR 17 Ib 1A Ia 1 11n 110 111 117 11- 11.5 114 114 115 11R 117 11R 11Q GENERAL NOTES: I. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS INCLUDING BUT NOT LIMITED TO THE INDIANA BUILDING CODE, THE INDIANA HANDICAPPED ACCESSIBILITY CODE, THE INDIANA PLUMBING, MECHANICAL, AND ELECTRICAL CODES, THE INDIANA FIRE CODE, THE AMERICANS WITH DISABILITIES ACT (ADA), AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITION. 2. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT /DESIGNER IMMEDIATELY. 3. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR THE COMPLETION OF THE PROJECT. FOR ALL CLASS 1 PROJECTS UNDER THE JURISDICTION OF THE INDIANAPOLIS FIRE DEPARTMENT (IFD), THE CONTRACTOR SHALL SUBMIT ONE FULL SET OF CONSTRUCTION DRAWINGS, INCLUDING ANY LIFE SAFETY SYSTEM DRAWINGS, TO THE IFD FOR PLAN REVIEW. REFERENCE TO THE INDIANAPOLIS DEPARTMENT OF METROPOLITAN DEVELOPMENT (DMD) STRUCTURAL PERMIT NUMBER SHALL BE INCLUDED. THE IFD PLAN REVIEW DMSION IS LOCATED AT 604 NORTH SHERMAN DRIVE, INDIANAPOLIS, INDIANA 46201. CONTRACTOR SHALL PAY ANY ASSOCIATED FEES FOR THIS SUBMITTAL 4. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S FIXTURES, FURNISHINGS, AND EQUIPMENT. 5. ALL DIMENSIONS REQUIRED ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONS OFF DRAWINGS. 6. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL MILLWORK/CASEWORK. CONTRACTOR SHALL SUBMIT A MINIMUM OF (3) SETS OF HARD COPY SUBMITTALS OR ONE PDF VERSION OF THE SUBMITTAL TO THE DESIGNER/ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE DESIGNER/ARCHITECT, THE CONTRACTOR SHALL SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THEY HAVE REVIEWED, APPROVED, AND THAT CONTRACTOR COORDINATION HAS BEEN PERFORMED ON SAID SHOP DRAWINGS. 7. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS, EXIT UGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED IN WORKING ORDER. 8. CONTRACTOR SHALL PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AND RECESSED CABINETS IN ACCORDANCE WITH NFPA 10. ALL LOCATIONS ARE TO BE COORDINATED WITH THE ARCHITECT /DESIGNER AND LOCAL OFFICIALS PRIOR TO INSTALLATION. 9. CONTRACTOR 15 TO SHOW PROOF OF ORDER OF FINISH MATERIALS WITHIN 30 DAYS OF AWARD OF CONTRACT. DESIGN FEES WILL ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. THE OWNER RESERVES THE RIGHT TO WITHHOLD PAYMENT FROM THE CONSTRUCTION CONTRACT TO COVER ANY AND ALL OF THESE FEES AND EXPENSES. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGNER/ARCHITECT IF A SPECIFIED ITEM BECOMES DISCONTINUED. 10. CONTRACTOR I5 RESPONSIBLE FOR COMPLETE PATCH AND REPAIR OF ALL SURFACES DAMAGED DURING DEMOLITION AND /OR CONSTRUCTION, ALL DAMAGED SURFACES SHALL BE REPAIRED OR REPLACED USING MATERIALS WITH MINIMUM QUALTY EQUAL TO THAT OF ORIGINAL OR ADJACENT MATERIAL, WHICHEVER QUALITY IS HIGHER. ALL REPAIRED /REPLACED SURFACES ME TO BE PREPARED TO RECEIVE FINISHES AS SCHEDULED WITHOUT VISIBLE SEAM OR SEPARATION. I I. ANY WORK DEVIATING FROM CONTRACT DOCUMENTS AND /OR SPECIFICATIONS SHALL ONLY BE MADE UPON WRITTEN APPROVAL OF THE DESIGNER/ARCHITECT AND THE OWNER'S DESIGNATED REPRESENTATIVE CHANGE ORDER REQUEST AND APPROVAL SHALL BE MADE PRIOR TO PROCEEDING WITH ANY CHANGE ORDER WORK. DESIGNER/ARCHITECT SHALL BE NOTIFIED OF ANY DELAY OF WORK THAT COULD RESULT BY THE DELAY IN CHANGE ORDER APPROVAL. 12. CONTRACTOR WILL BE RESPONSIBLE FOR DEVELOPING AND PROVIDING ALL MECHANICAL ELECTRICAL, PLUMBING, AND /OR SPRINKLER DRAWINGS AND CALCULATIONS AS REQUIRED TO MEET THE SCOPE OF WORK CALLED OUT FOR THE ATTACHED DRAWINGS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE FILING OF THESE DRAWINGS WITH THE APPROPRIATE GOVERNMENT BODY FOR CONSTRUCTION, IF REQUIRED. ALL ABOVE DOCUMENTS ARE TO BE REVIEWED AND APPROVED BY AMICA DESIGN ARCHITECT. ANY REFERENCE TO ENGINEER WITHIN THESE DOCUMENTS 15 REFERRING TO GENERAL CONTRACTORS SUB CONTRACTOR PROVIDING ABOVE DOCUMENTATION. PURCHASE AGREEMENTS: A AMICA HAS ESTABLISHED PURCHASE AGREEMENTS WITH THE FOLLOWING MANUFACTURERS OR VENDORS. THE GENERAL CONTRACTOR SHALL PROCURE MATERIALS FROM THESE MANUFACTURER'S FOR THIS PROJECT. GENERAL CONTRACTOR 15 RESPONSIBLE FOR INSTALLATION OF MATERIALS. MATERIALS SHALL BE INSTALLED BY GENERAL CONTRACTOR AS PER MANUFACTURER'S RECOMMENDATIONS AND AMICA'S SPECIFICATIONS: I. LIGHTING: COOPER LIGHTING: BRIAN MAITE M J ELECTRICAL SUPPLY, INC 31 WEST 377 SCHOGER ROAD NAPERVILLE, IL 60564 PHONE: 630.851.1925 E -MAIL: bmaite@mjelectricaLcom 2. FLOORING MATERIALS, INCLUDING CARPET, VCT, AND VINYL BASE MARK CASPER MOHAWK INDUSTRIES 377 MERCHANDISE MART CHICAGO, IL 60654 PHONE: 630.258.3366 E -MAIL: MARK_CASPER@MOHAWKIND.COM BUILDING PERFORMANCE SPECIFICATIONS: I. DESIGN CONDITIONS: INDOOR TEMP 1 MAX. HUMIDITY TO BE CONSISTENT WITH THE RANGES SET FOURTH IN THE LEASE. 2. TYPE: FAN POWERED VARIABLE AIR VOLUME 3. CONTROLS: ONE THERMOSTAT PER ZONE 4. AIR DISTRIBUTION: 1.0 TO 1.2 CFM 1 GROSS SQ. FT., PRIMARY AIR AT 55 DEGREE F AND 20 DEGREE TEMPERATURE RISE 5. NOISE LEVEL IN OFFICE AREAS NOT TO EXCEED 35 NC 6. ENERGY BUDGET: NEGATIVE PRESSURE MAINTAINED. 7. HEATING: MEETS ASHRAE STANDARD 90 ELECTRIC HEAT AT PERIMETER FAN POWERED BOXES. 8. ENERGY MANAGEMENT SYSTEM IS CENTRALIZED, COMPUTERIZED DDC MANAGEMENT SYSTEM. 9. FAN SYSTEM: ONE PER FLOOR IN BUILDING CORE, WIRED TO CENTRAL MANAGEMENT SYSTEM. 10. PREMISES SHALL BE PROVIDED WITH ELECTRICAL POWER TO SUPPORT TENANTS USE OF THE PREMISES AS DEPICTED IN THESE PLANS. HVAC NOTES: I. INTERIOR ZONING: ONE ZONE PER 1600 USABLE SQUARE FEET OPEN OFFICE, MINIMUM. 2. PERIMETER ZONING: ONE ZONE PER 800 USABLE SQUARE FEET, MINIMUM. 3. AVAILABLE TENANT SUPPLEMENTAL: COOLING: CHILLED WATER, CONDENSER WATER EXHAUST: KITCHEN EXHAUST, GENERAL EXHAUST, REPRODUCTION EQUIPMENT EXHAUST. 4. SEE SHEET A6I0 FOR LAN ROOM SUPPLEMENTAL COOLING REQUIREMENTS. 5. ALL THERMOSTATS, WITHIN ENCLOSED SPACES, ARE TO BE LOCATED WITHIN 6' ADJACENCY TO SWITCHING FOR THAT SPACE. THERMOSTATS IN OPEN AREAS ARE TO BE LOCATED WITHIN 6' OF CLOSEST EDGE OF A WALL AT 48" A.F.F. REFER TO FURNITURE DRAWINGS TO INSURE PROPER PLACEMENT WITHIN ENCLOSED SPACES. ELECTRICAL AND COMMUNICATIONS NOTES: I. SEE NOTES ON ELECTRICAL AND COMMUNICATION SHEET A810. 2. POWER POLES ARE NOT TO BE USED. POWER/COMMUNICATIONS I5 TO BE RUN THROUGH WALLS. IF POWER/COMMUNICATIONS CANNOT BE BROUGHT THROUGH WALLS, FLOOR CORES ARE TO BE USED. 3. A B. C. D. E. F. DEVICE COLORS ARE TO BE: ELECTRICAL IN DRYWALL PARTITION: T.B.D. DEDICATED ELECTRICAL IN DRYWALL PARTITION: T.B.D. COMMUNICATIONS IN DRYWALL PARTITION: VOICE WHITE, DATA BLACK, ANALOG: BLUE. ELECTRICAL IN FURNITURE: T.B.D. DEDICATED ELECTRICAL IN FURNITURE: T.B.D. COMMUNICATIONS IN FURNITURE VOICE: WHITE, DATA BLACK, ANALOG: BLUE. 4. WIRING TO BE DETERMINED BY ENGINEER. 5. COMPUTER OUTLETS ARE TO BE DEDICATED. 6. EACH WORKSTATION AREA REQUIRES (2) SHARED CIRCUITS MINIMUM (MAXIMUM OF (6) WORKSTATIONS TO BE LOCATED ON SHARED CIRCUITS. FINAL CIRCUITING TO BE BY ENGINEER.) 7. CONTRACTOR SHALL REMOVE ALL EXISTING CABLING. 8. COMMUNICATIONS ARE FOR REFERENCE ONLY. AMICA VENDOR TO INSTALL ALL COMMUNICATIONS WIRING. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL INFRASTRUCTURE (CONDUIT AND PULL STRINGS) REQUIRED FOR THE INSTALLATION OF CABLING. CONTRACTOR TO CONFIRM ALL CONDUIT SIZING BASED ON SPECIFICATIONS INDICATED. 9. TO STAY COMPLIANT WITH N EC AND TIA 568 THE FOLLOWING CHART IS TO BE ADHERED TO FOR SIZING FLEX TUBING, CONDUIT AND SLEEVES (WALL PENETRATIONS NO BENDS LENGTH NOT TO EXCEED 24"). NUMBER OF CABLES: 10. WIRING TYPES: DATA CAT 6; VOICE: CAT 6. DOORS AND WINDOWS: MAX FILL SYSTIMAX CAT 6 UTP/ CMP WITH 0.215 NOMINAL DIAMETER SIZE I I. LOW VOLTAGE CABLING: ALL LOW VOLTAGE CABLING IS TO BE COLOR COORDINATED. AVAYA COMMSCOPE SYSTIMAX STANDARDS ARE TO BE USED FOR LOW VOLTAGE CABUNG. AMICA TO PROVIDE COMPLETE SPECIFICATIONS FOR ALL LOW VOLTAGE REQUIREMENTS. 12. SYSTEMS FURNITURE POWERI COMMUNICATION SUPPLIED THROUGH SYSTEMS FURNITURE WALLS AND PANELS SHALL COMPLY WITH ALL LOCAL AND STATE BUILDING AND ELECTRICAL CODES. 13. CARD READER SYSTEM: FINAL SYSTEM SPECIFICATION TO BE APPROVED BY AMICA AND THEIR DESIGN ARCHITECT. CONTRACTOR TO PROVIDE INFRASTRUCTURE TO INSTALL SYSTEM. AMICA VENDOR TO PROVIDE AND INSTALL CARD READER SYSTEM. FINAL CARD READER LOCATIONS TO BE APPROVED BY AMICA AND THEIR DESIGN ARCHITECT. I. ALL DOORS ARE TO BE FULL HEIGHT SOLID CORE HARDWOOD OR BUILDING STANDARD. DOORS ARE TO BE STAINED TO MATCH BUILDING STANDARD. 2. MINIMUM DOOR HARDWARE TO INCLUDE: (4) HINGES, STANLEY US26, 4-1/2" X 41/2" FBBI79, (1) MORTISE LOCKSET: SCHLAGE 625 L9080P 07A, (1) FLOOR STOP. HAGAR, U526F. 3. ALL WINDOWS SHALL HAVE MINI BLINDS, IF NOT ALREADY IN PLACE. 1 AREA OF WORK 111 moommom 11 11111111111111111111 1 1111111 1111111111111111 1111111111111111 111 11 11111111111111111 NTS 1 n I 1 1 KEY PLAN 00:1/ NO SCALE PLUMBING RISER DIAGRAM b b 119 U Q W IT z 0 co 0 Q U O Z 0_ 0 d U Vn W 0 L O 0 Z w 0 0- LJ 0 GO U_ 0 OD 0 N z Q 0 w CC 0 U 0 0 0 z O O C(3)1= 1 W N 0 1 N O r Z Y O O r 0 N 0 0 4 I w 1 w DRAWING NO. A00 I SHEET OF R 0 P N M L K H G F E D C B R 0 P N M L K H F E D C B TITLE: A GENERAL NOTES A 3/4" I" 2" 4" FLEX TUBING 6 8 CONDUIT 8 10 40 120 CONDUIT 12 48 150 11 17 1 1 li 1 1 s 14 15 1b IR 17 Ib 1A Ia 1 11n 110 111 117 11- 11.5 114 114 115 11R 117 11R 11Q GENERAL NOTES: I. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS INCLUDING BUT NOT LIMITED TO THE INDIANA BUILDING CODE, THE INDIANA HANDICAPPED ACCESSIBILITY CODE, THE INDIANA PLUMBING, MECHANICAL, AND ELECTRICAL CODES, THE INDIANA FIRE CODE, THE AMERICANS WITH DISABILITIES ACT (ADA), AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITION. 2. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT /DESIGNER IMMEDIATELY. 3. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR THE COMPLETION OF THE PROJECT. FOR ALL CLASS 1 PROJECTS UNDER THE JURISDICTION OF THE INDIANAPOLIS FIRE DEPARTMENT (IFD), THE CONTRACTOR SHALL SUBMIT ONE FULL SET OF CONSTRUCTION DRAWINGS, INCLUDING ANY LIFE SAFETY SYSTEM DRAWINGS, TO THE IFD FOR PLAN REVIEW. REFERENCE TO THE INDIANAPOLIS DEPARTMENT OF METROPOLITAN DEVELOPMENT (DMD) STRUCTURAL PERMIT NUMBER SHALL BE INCLUDED. THE IFD PLAN REVIEW DMSION IS LOCATED AT 604 NORTH SHERMAN DRIVE, INDIANAPOLIS, INDIANA 46201. CONTRACTOR SHALL PAY ANY ASSOCIATED FEES FOR THIS SUBMITTAL 4. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S FIXTURES, FURNISHINGS, AND EQUIPMENT. 5. ALL DIMENSIONS REQUIRED ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONS OFF DRAWINGS. 6. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL MILLWORK/CASEWORK. CONTRACTOR SHALL SUBMIT A MINIMUM OF (3) SETS OF HARD COPY SUBMITTALS OR ONE PDF VERSION OF THE SUBMITTAL TO THE DESIGNER/ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE DESIGNER/ARCHITECT, THE CONTRACTOR SHALL SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THEY HAVE REVIEWED, APPROVED, AND THAT CONTRACTOR COORDINATION HAS BEEN PERFORMED ON SAID SHOP DRAWINGS. 7. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS, EXIT UGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED IN WORKING ORDER. 8. CONTRACTOR SHALL PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AND RECESSED CABINETS IN ACCORDANCE WITH NFPA 10. ALL LOCATIONS ARE TO BE COORDINATED WITH THE ARCHITECT /DESIGNER AND LOCAL OFFICIALS PRIOR TO INSTALLATION. 9. CONTRACTOR 15 TO SHOW PROOF OF ORDER OF FINISH MATERIALS WITHIN 30 DAYS OF AWARD OF CONTRACT. DESIGN FEES WILL ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. THE OWNER RESERVES THE RIGHT TO WITHHOLD PAYMENT FROM THE CONSTRUCTION CONTRACT TO COVER ANY AND ALL OF THESE FEES AND EXPENSES. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGNER/ARCHITECT IF A SPECIFIED ITEM BECOMES DISCONTINUED. 10. CONTRACTOR I5 RESPONSIBLE FOR COMPLETE PATCH AND REPAIR OF ALL SURFACES DAMAGED DURING DEMOLITION AND /OR CONSTRUCTION, ALL DAMAGED SURFACES SHALL BE REPAIRED OR REPLACED USING MATERIALS WITH MINIMUM QUALTY EQUAL TO THAT OF ORIGINAL OR ADJACENT MATERIAL, WHICHEVER QUALITY IS HIGHER. ALL REPAIRED /REPLACED SURFACES ME TO BE PREPARED TO RECEIVE FINISHES AS SCHEDULED WITHOUT VISIBLE SEAM OR SEPARATION. I I. ANY WORK DEVIATING FROM CONTRACT DOCUMENTS AND /OR SPECIFICATIONS SHALL ONLY BE MADE UPON WRITTEN APPROVAL OF THE DESIGNER/ARCHITECT AND THE OWNER'S DESIGNATED REPRESENTATIVE CHANGE ORDER REQUEST AND APPROVAL SHALL BE MADE PRIOR TO PROCEEDING WITH ANY CHANGE ORDER WORK. DESIGNER/ARCHITECT SHALL BE NOTIFIED OF ANY DELAY OF WORK THAT COULD RESULT BY THE DELAY IN CHANGE ORDER APPROVAL. 12. CONTRACTOR WILL BE RESPONSIBLE FOR DEVELOPING AND PROVIDING ALL MECHANICAL ELECTRICAL, PLUMBING, AND /OR SPRINKLER DRAWINGS AND CALCULATIONS AS REQUIRED TO MEET THE SCOPE OF WORK CALLED OUT FOR THE ATTACHED DRAWINGS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE FILING OF THESE DRAWINGS WITH THE APPROPRIATE GOVERNMENT BODY FOR CONSTRUCTION, IF REQUIRED. ALL ABOVE DOCUMENTS ARE TO BE REVIEWED AND APPROVED BY AMICA DESIGN ARCHITECT. ANY REFERENCE TO ENGINEER WITHIN THESE DOCUMENTS 15 REFERRING TO GENERAL CONTRACTORS SUB CONTRACTOR PROVIDING ABOVE DOCUMENTATION. PURCHASE AGREEMENTS: A AMICA HAS ESTABLISHED PURCHASE AGREEMENTS WITH THE FOLLOWING MANUFACTURERS OR VENDORS. THE GENERAL CONTRACTOR SHALL PROCURE MATERIALS FROM THESE MANUFACTURER'S FOR THIS PROJECT. GENERAL CONTRACTOR 15 RESPONSIBLE FOR INSTALLATION OF MATERIALS. MATERIALS SHALL BE INSTALLED BY GENERAL CONTRACTOR AS PER MANUFACTURER'S RECOMMENDATIONS AND AMICA'S SPECIFICATIONS: I. LIGHTING: COOPER LIGHTING: BRIAN MAITE M J ELECTRICAL SUPPLY, INC 31 WEST 377 SCHOGER ROAD NAPERVILLE, IL 60564 PHONE: 630.851.1925 E -MAIL: bmaite@mjelectricaLcom 2. FLOORING MATERIALS, INCLUDING CARPET, VCT, AND VINYL BASE MARK CASPER MOHAWK INDUSTRIES 377 MERCHANDISE MART CHICAGO, IL 60654 PHONE: 630.258.3366 E -MAIL: MARK_CASPER@MOHAWKIND.COM BUILDING PERFORMANCE SPECIFICATIONS: I. DESIGN CONDITIONS: INDOOR TEMP 1 MAX. HUMIDITY TO BE CONSISTENT WITH THE RANGES SET FOURTH IN THE LEASE. 2. TYPE: FAN POWERED VARIABLE AIR VOLUME 3. CONTROLS: ONE THERMOSTAT PER ZONE 4. AIR DISTRIBUTION: 1.0 TO 1.2 CFM 1 GROSS SQ. FT., PRIMARY AIR AT 55 DEGREE F AND 20 DEGREE TEMPERATURE RISE 5. NOISE LEVEL IN OFFICE AREAS NOT TO EXCEED 35 NC 6. ENERGY BUDGET: NEGATIVE PRESSURE MAINTAINED. 7. HEATING: MEETS ASHRAE STANDARD 90 ELECTRIC HEAT AT PERIMETER FAN POWERED BOXES. 8. ENERGY MANAGEMENT SYSTEM IS CENTRALIZED, COMPUTERIZED DDC MANAGEMENT SYSTEM. 9. FAN SYSTEM: ONE PER FLOOR IN BUILDING CORE, WIRED TO CENTRAL MANAGEMENT SYSTEM. 10. PREMISES SHALL BE PROVIDED WITH ELECTRICAL POWER TO SUPPORT TENANTS USE OF THE PREMISES AS DEPICTED IN THESE PLANS. HVAC NOTES: I. INTERIOR ZONING: ONE ZONE PER 1600 USABLE SQUARE FEET OPEN OFFICE, MINIMUM. 2. PERIMETER ZONING: ONE ZONE PER 800 USABLE SQUARE FEET, MINIMUM. 3. AVAILABLE TENANT SUPPLEMENTAL: COOLING: CHILLED WATER, CONDENSER WATER EXHAUST: KITCHEN EXHAUST, GENERAL EXHAUST, REPRODUCTION EQUIPMENT EXHAUST. 4. SEE SHEET A6I0 FOR LAN ROOM SUPPLEMENTAL COOLING REQUIREMENTS. 5. ALL THERMOSTATS, WITHIN ENCLOSED SPACES, ARE TO BE LOCATED WITHIN 6' ADJACENCY TO SWITCHING FOR THAT SPACE. THERMOSTATS IN OPEN AREAS ARE TO BE LOCATED WITHIN 6' OF CLOSEST EDGE OF A WALL AT 48" A.F.F. REFER TO FURNITURE DRAWINGS TO INSURE PROPER PLACEMENT WITHIN ENCLOSED SPACES. ELECTRICAL AND COMMUNICATIONS NOTES: I. SEE NOTES ON ELECTRICAL AND COMMUNICATION SHEET A810. 2. POWER POLES ARE NOT TO BE USED. POWER/COMMUNICATIONS I5 TO BE RUN THROUGH WALLS. IF POWER/COMMUNICATIONS CANNOT BE BROUGHT THROUGH WALLS, FLOOR CORES ARE TO BE USED. 3. A B. C. D. E. F. DEVICE COLORS ARE TO BE: ELECTRICAL IN DRYWALL PARTITION: T.B.D. DEDICATED ELECTRICAL IN DRYWALL PARTITION: T.B.D. COMMUNICATIONS IN DRYWALL PARTITION: VOICE WHITE, DATA BLACK, ANALOG: BLUE. ELECTRICAL IN FURNITURE: T.B.D. DEDICATED ELECTRICAL IN FURNITURE: T.B.D. COMMUNICATIONS IN FURNITURE VOICE: WHITE, DATA BLACK, ANALOG: BLUE. 4. WIRING TO BE DETERMINED BY ENGINEER. 5. COMPUTER OUTLETS ARE TO BE DEDICATED. 6. EACH WORKSTATION AREA REQUIRES (2) SHARED CIRCUITS MINIMUM (MAXIMUM OF (6) WORKSTATIONS TO BE LOCATED ON SHARED CIRCUITS. FINAL CIRCUITING TO BE BY ENGINEER.) 7. CONTRACTOR SHALL REMOVE ALL EXISTING CABLING. 8. COMMUNICATIONS ARE FOR REFERENCE ONLY. AMICA VENDOR TO INSTALL ALL COMMUNICATIONS WIRING. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL INFRASTRUCTURE (CONDUIT AND PULL STRINGS) REQUIRED FOR THE INSTALLATION OF CABLING. CONTRACTOR TO CONFIRM ALL CONDUIT SIZING BASED ON SPECIFICATIONS INDICATED. 9. TO STAY COMPLIANT WITH N EC AND TIA 568 THE FOLLOWING CHART IS TO BE ADHERED TO FOR SIZING FLEX TUBING, CONDUIT AND SLEEVES (WALL PENETRATIONS NO BENDS LENGTH NOT TO EXCEED 24"). NUMBER OF CABLES: 10. WIRING TYPES: DATA CAT 6; VOICE: CAT 6. DOORS AND WINDOWS: MAX FILL SYSTIMAX CAT 6 UTP/ CMP WITH 0.215 NOMINAL DIAMETER SIZE I I. LOW VOLTAGE CABLING: ALL LOW VOLTAGE CABLING IS TO BE COLOR COORDINATED. AVAYA COMMSCOPE SYSTIMAX STANDARDS ARE TO BE USED FOR LOW VOLTAGE CABUNG. AMICA TO PROVIDE COMPLETE SPECIFICATIONS FOR ALL LOW VOLTAGE REQUIREMENTS. 12. SYSTEMS FURNITURE POWERI COMMUNICATION SUPPLIED THROUGH SYSTEMS FURNITURE WALLS AND PANELS SHALL COMPLY WITH ALL LOCAL AND STATE BUILDING AND ELECTRICAL CODES. 13. CARD READER SYSTEM: FINAL SYSTEM SPECIFICATION TO BE APPROVED BY AMICA AND THEIR DESIGN ARCHITECT. CONTRACTOR TO PROVIDE INFRASTRUCTURE TO INSTALL SYSTEM. AMICA VENDOR TO PROVIDE AND INSTALL CARD READER SYSTEM. FINAL CARD READER LOCATIONS TO BE APPROVED BY AMICA AND THEIR DESIGN ARCHITECT. I. ALL DOORS ARE TO BE FULL HEIGHT SOLID CORE HARDWOOD OR BUILDING STANDARD. DOORS ARE TO BE STAINED TO MATCH BUILDING STANDARD. 2. MINIMUM DOOR HARDWARE TO INCLUDE: (4) HINGES, STANLEY US26, 4-1/2" X 41/2" FBBI79, (1) MORTISE LOCKSET: SCHLAGE 625 L9080P 07A, (1) FLOOR STOP. HAGAR, U526F. 3. ALL WINDOWS SHALL HAVE MINI BLINDS, IF NOT ALREADY IN PLACE. 1 AREA OF WORK 111 moommom 11 11111111111111111111 1 1111111 1111111111111111 1111111111111111 111 11 11111111111111111 NTS 1 n I 1 1 KEY PLAN 00:1/ NO SCALE PLUMBING RISER DIAGRAM b b 119 U Q W IT z 0 co 0 Q U O Z 0_ 0 d U Vn W 0 L O 0 Z w 0 0- LJ 0 GO U_ 0 OD 0 N z Q 0 w CC 0 U 0 0 0 z O O C(3)1= 1 W N 0 1 N O r Z Y O O r 0 N 0 0 4 I w 1 w DRAWING NO. A00 I SHEET OF R 0 P N M L K H G F E D C B R 0 P N M L K H F E D C B TITLE: A GENERAL NOTES A