HomeMy WebLinkAboutBLW-039 Sealed Truss Drawings.PDFRe:
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI-2002 Chapter 2.
The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision
based on the parameters provided by Carter Lee Building Components.
Liu, Xuegang
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Pages or sheets covered by this seal: I16269203 thru I16269224
My license renewal date for the state of Indiana is July 31, 2010.
Q0150310
14515 North Outer Forty Drive
Suite 300
Chesterfield, MO 63017-5746
MiTek Industries, Inc.
March 4,2010
Job
Q0150310
Truss
GE1
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269204
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:46 2010 Page 1
Scale = 1:69.6
1
2
3
4 5
6
7
8
9
21 20
19 18 17 1615 14 13 12 11 10
4x6 4x8
3x6
3x12
4x6
4x6
3x4
3x6
3x4
4x8
4x8
2x4
2x4
2x4
2x4
5x6
9-2-0
9-2-0
12-9-0
3-7-0
17-10-12
5-1-12
23-2-0
5-3-4
-0-10-0
0-10-0
4-8-12
4-8-12
9-2-0
4-5-4
12-9-0
3-7-0
17-10-12
5-1-12
23-2-0
5-3-4
Job
Q0150310
Truss
GE2
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269205
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:47 2010 Page 1
Scale = 1:49.4
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
3x4
3x4
4x6
3x4
3x4
11-3-0
11-3-0
-0-10-0
0-10-0
5-7-8
5-7-8
11-3-0
5-7-8
12-1-0
0-10-0
1-10-0
7-5-8
1-10-0
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
Job
Q0150310
Truss
GE3
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269206
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:48 2010 Page 1
Scale = 1:71.1
1
2
3
4 5
6
7
8
15 14 13 12
11
10 9
16 17 18
4x8 4x6
2x4
4x6
3x6
3x4 3x4 3x12
3x6
3x4
4x6
2x4
4x6
Nailed
Nailed
Nailed
Nailed
Nailed
4-4-9
4-4-9
8-5-10
4-1-1
12-6-6
4-0-12
16-7-7
4-1-1
21-0-0
4-4-9
-0-10-0
0-10-0
4-4-9
4-4-9
8-5-10
4-1-1
12-6-6
4-0-12
16-7-7
Job
Q0150310
Truss
GE4
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269207
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:50 2010 Page 1
Scale = 1:52.2
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
3x6
3x6
4x6
3x6
3x6
10-8-8
10-8-8
-0-10-0
0-10-0
5-4-4
5-4-4
10-8-8
5-4-4
11-6-8
0-10-0
2-6-6
7-10-10
2-6-6
12.00 12
Plate Offsets (X,Y): [10:0-0-0,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Job
Q0150310
Truss
GE5
Truss Type
GABLE
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269208
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:53 2010 Page 1
Scale = 1:26.2
1
2
3
4
5
9 8 7 6
2x4
1.5x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
7-5-8
7-5-8
7-5-8
7-5-8
3-8-12
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.15
Job
Q0150310
Truss
GE6
Truss Type
GABLE
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269209
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:54 2010 Page 1
Scale = 1:51.0
1
2
3
4
5
6
7
8
9
10
11
12
3x4 23 22 21 20 19 18 17 16 15 14 13
3x6
3x4
16-8-8
16-8-8
16-8-8
16-8-8
8-4-4
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
Job
Q0150310
Truss
GE7
Truss Type
GABLE
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269210
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:11:57 2010 Page 1
Scale = 1:68.5
1 2
3 4
5
6
7
8
9
10
11
12
13
14
15 16
17
18
19
20
21
22
23
24
25
26
27
28
29
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30
3x6
5x6
3x6
3x6
3x6 3x6
3x6
36-0-8
36-0-8
-0-10-0
0-10-0
18-0-4
18-0-4
36-0-8
18-0-4
36-10-8
0-10-0
0-6-0
9-6-2
Job
Q0150310
Truss
GE8
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269211
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:00 2010 Page 1
Scale = 1:73.0
1
2
3
4
5
6
7
8
9
10
20 19
18
17 16
15 14
13 12 11
3x6
5x6
3x6
10x10
6x8
3x4
3x6 3x6
4x6
3x4
4x8
3x6
3x6
3x4
4x10
2x4
2x4
2x4
2x4
5x6
4x6
2-0-8
2-0-8
7-9-12
5-9-4
13-7-0
5-9-4
20-10-14
7-3-14
28-2-13
7-3-14
Job
Q0150310
Truss
GE9
Truss Type
GABLE
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269212
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:02 2010 Page 1
Scale = 1:50.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24
3x6
4x6
3x6
3x4
3x6
3x4
27-9-8
27-9-8
-0-10-0
0-10-0
13-10-12
13-10-12
27-9-8
13-10-12
28-7-8
0-10-0
0-6-0
7-5-6
0-6-0
6.00 12
LOADING (psf)
Job
Q0150310
Truss
GR1
Truss Type
ROOF TRUSS
Qty
1
Ply
2
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269213
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:04 2010 Page 1
Scale = 1:74.4
1
2
3 4
5
6
7
8
14 13 12 11 10
15 16 17 18 19 20 21 9 22 23
6x10
5x10 MT18H
8x8
3x6
4x10
8x8 WB
3x6
10x10 10x10 10x10
4x10
3x12
6x16
Nailed
4-8-12
4-8-12
9-2-0
4-5-4
12-9-0
3-7-0
17-9-12
5-0-12
23-2-0
5-4-4
4-8-12
4-8-12
9-2-0
4-5-4
12-9-0
3-7-0
17-9-12
5-0-12
23-2-0
5-4-4
24-0-0
0-10-0
1-10-0
11-0-0
Job
Q0150310
Truss
GR1
Truss Type
ROOF TRUSS
Qty
1
Ply
2
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269213
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:04 2010 Page 2
NOTES
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1588 lb down and 256 lb up at 1-10-12, 1588 lb down and 256 lb up at
3-10-12, 1588 lb down and 256 lb up at 5-10-12, 1588 lb down and 256 lb up at 7-10-12, 1588 lb down and 256 lb up at 9-10-12, 1588 lb down and 256 lb up at 11-10-12, 1588
lb down and 256 lb up at 13-10-12, 1588 lb down and 256 lb up at 15-10-12, 1588 lb down and 256 lb up at 17-10-12, and 1588 lb down and 256 lb up at 19-10-12, and 1593 lb
down and 257 lb up at 21-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-70, 3-4=-70, 4-8=-70, 7-14=-20
Concentrated Loads (lb)
Vert: 10=-1588(B) 9=-1588(B) 7=-24(B) 15=-1588(B) 16=-1588(B) 17=-1588(B) 18=-1588(B) 19=-1588(B) 20=-1588(B) 21=-1588(B) 22=-1588(B) 23=-1593(B)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
Job
Q0150310
Truss
H1
Truss Type
ROOF TRUSS
Qty
5
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269214
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:05 2010 Page 1
Scale = 1:67.5
1
2
3 4
5
6
11 10 9 8
7
3x4
4x6 4x8
3x4
3x6
3x12
4x6
3x4
4x6
4x6 4x6
8-5-10
8-5-10
12-6-6
4-0-12
21-0-0
8-5-10
4-4-9
4-4-9
8-5-10
4-1-1
12-6-6
4-0-12
16-7-7
4-1-1
21-0-0
4-4-9
2-6-6
11-0-0
2-6-6
11-0-0
12.00 12
Plate Offsets (X,Y): [3:0-4-4,0-1-12], [4:0-6-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
Job
Q0150310
Truss
J8
Truss Type
ROOF TRUSS
Qty
5
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269215
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:05 2010 Page 1
Scale = 1:19.0
1
2
5
3
4
3x4
3x4
2-0-0
2-0-0
-0-10-0
0-10-0
2-0-0
2-0-0
2-1-6
3-1-6
2-7-11
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.32
0.17
0.00
DEFL
Job
Q0150310
Truss
PB1
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269216
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:06 2010 Page 1
Scale = 1:11.3
1
2
3
4
5
6
4x6
2x4 1.5x4 2x4
3-7-0
3-7-0
1-9-8
1-9-8
3-7-0
1-9-8
0-5-3
1-9-4
0-1-8
0-5-3
0-1-8
12.00 12
Plate Offsets (X,Y): [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
Job
Q0150310
Truss
PB2
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269217
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:07 2010 Page 1
Scale: 1"=1’
1
2
3
2x4 4
4x6
2x4
1.5x4
1-9-8
1-9-8
3-7-0
1-9-8
1-9-8
1-9-8
3-7-0
1-9-8
1-9-8
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.06
0.04
0.03
DEFL
Job
Q0150310
Truss
PB3
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269218
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:07 2010 Page 1
Scale = 1:13.2
1
2
3
2x4 4
4x6
2x4
1.5x4
2-0-6
2-0-6
4-0-12
2-0-6
2-0-6
2-0-6
4-0-12
2-0-6
2-0-6
12.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.08
0.05
0.04
DEFL
Job
Q0150310
Truss
PB4
Truss Type
ROOF TRUSS
Qty
10
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269219
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:08 2010 Page 1
Scale = 1:12.5
1
2
3
4
5
6
4x6
2x4 1.5x4 2x4
4-0-12
4-0-12
2-0-6
2-0-6
4-0-12
2-0-6
0-5-3
2-0-2
0-1-8
0-5-3
0-1-8
12.00 12
Plate Offsets (X,Y): [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
Job
Q0150310
Truss
T1
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269220
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:09 2010 Page 1
Scale = 1:51.5
1
2
3
4
7 6 5
4x6
6x8
2x4 3x12 2x4
6x8
5-4-4
5-4-4
10-8-8
5-4-4
-0-10-0
0-10-0
5-4-4
5-4-4
10-8-8
5-4-4
2-6-6
7-10-10
2-6-6
12.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge], [4:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
Job
Q0150310
Truss
T2
Truss Type
ROOF TRUSS
Qty
5
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269221
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:10 2010 Page 1
Scale = 1:67.5
1
2
3
4 5
6
7
8
13 12 11 10
9
4x6 4x8
3x6
3x12
4x6
3x4
4x6
3x4
4x6 4x6
3x4
8-5-10
8-5-10
12-6-6
4-0-12
21-0-0
8-5-10
-0-10-0
0-10-0
4-4-9
4-4-9
8-5-10
4-1-1
12-6-6
4-0-12
16-7-7
4-1-1
21-0-0
4-4-9
21-10-0
0-10-0
2-6-6
11-0-0
2-6-6
11-0-0
12.00 12
Plate Offsets (X,Y): [4:0-4-4,0-1-12], [5:0-6-4,0-1-12]
LOADING (psf)
Job
Q0150310
Truss
T3A
Truss Type
ROOF TRUSS
Qty
11
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269222
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:11 2010 Page 1
Scale = 1:65.7
1 2
3
4
5
6
7
8
9
10
15 14 13
12 11
3x6
5x6
3x6
5x8
3x6
3x12
3x4
3x4
1.5x4
3x4
3x4
1.5x4
5x8
3x6
9-1-9
9-1-9
18-0-4
8-10-11
26-10-15
8-10-11
36-0-8
9-1-9
-0-10-0
0-10-0
6-1-15
6-1-15
12-1-2
5-11-2
18-0-4
5-11-2
23-11-6
5-11-2
29-10-9
5-11-2
Job
Q0150310
Truss
T3B
Truss Type
ROOF TRUSS
Qty
1
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269223
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:13 2010 Page 1
Scale = 1:65.2
1
2
3
4
5
6
7
8
9
14 13
12
11 10
3x6
5x6
3x6
5x8
3x6 3x12
3x4
3x4
1.5x4
3x4
3x4
1.5x4
5x8
3x6
9-1-9
9-1-9
18-0-4
8-10-11
26-10-15
8-10-11
36-0-8
9-1-9
6-1-15
6-1-15
12-1-2
5-11-2
18-0-4
5-11-2
23-11-6
5-11-2
29-10-9
5-11-2
36-0-8
6-1-15
Job
Q0150310
Truss
T6
Truss Type
SPECIAL
Qty
6
Ply
1
q0150310 lot#39 BELLEWOOD JOB#BLW-039
Job Reference (optional)
I16269224
CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158 7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Mar 04 08:12:14 2010 Page 1
Scale = 1:51.6
1
2
3
4
5
6
7
8
13 12
11
5x12 10 9
5x6
3x6
10x16
6x8
3x6
4x8
3x4
4x6
5x6
3x4
2-0-8
2-0-8
7-10-2
5-9-10
13-7-0
5-8-14
20-5-11
6-10-11
27-6-8
7-0-13
2-0-8
2-0-8
7-10-2
5-9-10
13-7-12
5-9-10
20-5-11
6-9-15
27-6-8
7-0-13
28-4-8
0-10-0
0-7-8
7-5-6
WEBS
6-4-8 dimensions shown in ft-in-sixteenths
Industry Standards:
Plate location details available in MiTek 20/20
software or upon request.
*
Symbols Numbering System General Safety Notes
PLATE LOCATION AND ORIENTATION
3/
4
1 "
For 4 x 2 orientation, locate
plates 0-
1/
16"
This symbol indicates the
required direction of slots in
connector plates.
PLATE SIZE
4 x 4
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T, I or Eliminator bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
BEARING
TOP CHORDS
BOTTOM CHORDS
1 2 3
4
8 7 6 5
TOP CHORD
TOP CHORD
C1-2 C2-3
C3-4
C4-5
C7-8 C6-7 C5-6
C1-8
W1-7
W2-7
W3-7
W3-6
W4-6
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
ICC-ES Reports:
ESR-1311, ESR-1352, ER-5243, 9604B,
95-43, 96-31, 9667A
NER-487, NER-561
95110, 84-32, 96-67, ER-3907, 9432A
0-
1/
16" from outside
edge of truss.
WEBS
MiTek Engineering Reference Sheet: MII-7473 rev. 10-’08
' 2006 MiTekfi All Rights Reserved
dimensions shown in ft-in-sixteenths
(Drawings not to scale)
6-4-8
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Industry Standards:
Plate location details available in MiTek 20/20
software or upon request.
*
General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative T, I, or Eliminator
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.
Symbols Numbering System
PLATE LOCATION AND ORIENTATION
3/
4
1 " Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
For 4 x 2 orientation, locate
plates 0-
1/
16"
This symbol indicates the
required direction of slots in
connector plates.
PLATE SIZE
4 x 4
The first dimension is the plate
width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T, I or Eliminator bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
LATERAL BRACING LOCATION
BEARING
TOP CHORDS
BOTTOM CHORDS
1 2 3
4
8 7 6 5
TOP CHORD
TOP CHORD
C1-2 C2-3
C3-4
C4-5
C7-8 C6-7 C5-6
C1-8
W1-7
W2-7
W3-7
W3-6
W4-6
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
0-
1/
16" from outside
edge of truss.
0-6-0
0-8-0
6.00 12
4.57 12
Plate Offsets (X,Y): [1:0-6-0,0-2-0], [7:0-0-3,0-0-9], [11:0-2-12,0-2-8], [13:0-6-6,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.57
1.00
0.77
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.38
0.21
(loc)
12-13
12-13
7
l/defl
>999
>864
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 116 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2 *Except*
4-10: 2 X 4 SPF Stud, 1-13: 2 X 4 SYP No.1
WEBS 2 X 4 SPF Stud *Except*
2-13: 2 X 6 SPF No.2
SLIDER Left 2 X 3 SPF No.2 2-3-15
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=1227/Mechanical, 7=1298/0-3-8
Max Horz 1=-102(LC 6)
Max Uplift1=-185(LC 5), 7=-233(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4049/668, 2-3=-2283/355, 3-4=-1561/275, 4-6=-1589/286, 6-7=-2151/317
BOT CHORD 12-13=-576/2965, 11-12=-276/1994, 4-11=-93/886, 9-10=-9/275, 7-9=-174/1804,
1-13=-647/3506
WEBS 3-12=0/370, 3-11=-793/233, 9-11=-187/1537, 6-11=-585/221, 2-13=-142/1226,
2-12=-980/303
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=185.
6) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 7.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0-6-0
9-6-2
0-6-0
6.00 12
Plate Offsets (X,Y): [1:0-0-3,0-1-1], [9:0-0-3,0-1-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.60
0.94
0.29
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.17
-0.52
0.16
(loc)
12
9-10
9
l/defl
>999
>828
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 141 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
5-12,6-12,4-12: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 6-12, 4-12
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=1613/0-3-8, 9=1613/Mechanical
Max Horz 1=-121(LC 3)
Max Uplift1=-244(LC 5), 9=-245(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2929/468, 2-4=-2661/442, 4-5=-1886/370, 5-6=-1886/370, 6-8=-2678/445,
8-9=-2954/473
BOT CHORD 1-14=-447/2519, 12-14=-277/2084, 10-12=-176/2091, 9-10=-336/2548
WEBS 5-12=-171/1181, 6-12=-728/265, 6-10=-58/513, 8-10=-359/217, 4-12=-719/264,
4-14=-55/497, 2-14=-342/213
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=245.
6) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 1.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
36-0-8
6-1-15
0-6-0
9-6-2
0-6-0
6.00 12
Plate Offsets (X,Y): [2:0-0-3,0-1-1], [10:0-0-3,0-1-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.57
0.92
0.29
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.17
-0.50
0.16
(loc)
13
10-11
10
l/defl
>999
>859
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 142 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
6-13,7-13,5-13: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-9-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 7-13, 5-13
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=1678/0-3-8, 10=1608/Mechanical
Max Horz 2=130(LC 5)
Max Uplift2=-290(LC 5), 10=-244(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2913/461, 3-5=-2645/435, 5-6=-1876/369, 6-7=-1876/368, 7-9=-2651/441,
9-10=-2920/467
BOT CHORD 2-15=-440/2502, 13-15=-273/2073, 11-13=-173/2075, 10-11=-330/2510
WEBS 6-13=-170/1172, 7-13=-719/264, 7-11=-55/497, 9-11=-342/214, 5-13=-716/262,
5-15=-50/491, 3-15=-337/210
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=244.
6) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 2.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.43
0.72
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.28
0.02
(loc)
9-11
9-11
9
l/defl
>999
>876
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 134 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-12
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 13=1000/0-3-8, 9=1000/0-3-8
Max Horz 13=-373(LC 3)
Max Uplift13=-146(LC 5), 9=-146(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-736/254, 4-5=-449/246, 5-6=-736/254, 2-13=-304/243, 7-9=-304/243
BOT CHORD 12-13=-247/475, 11-12=-95/448, 9-11=-46/475
WEBS 3-13=-720/119, 6-9=-719/119
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 13 and 9.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
BC
WB
(Matrix)
0.38
0.17
0.08
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
-0.00
(loc)
6-7
6-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 57 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
2-6,4-6: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 7=541/0-3-8, 5=466/0-3-8
Max Horz 7=290(LC 4)
Max Uplift7=-82(LC 5), 5=-82(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-389/138, 3-4=-388/142, 2-7=-487/108, 4-5=-411/108
BOT CHORD 6-7=-293/271
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 7 and 5.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0.04
0.02
0.01
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
4
4
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 11 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=106/2-11-6, 4=106/2-11-6, 6=97/2-11-6
Max Horz 2=50(LC 4)
Max Uplift2=-36(LC 5), 4=-41(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 2 and 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=170/0-3-8, 3=170/0-3-8
Max Horz 1=-53(LC 3)
Max Uplift1=-23(LC 5), 3=-23(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
4
4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 10 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-7-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=148/0-3-8, 3=148/0-3-8
Max Horz 1=45(LC 4)
Max Uplift1=-20(LC 5), 3=-20(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0.03
0.02
0.01
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
4
4
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 10 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-7-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=93/2-5-10, 4=93/2-5-10, 6=80/2-5-10
Max Horz 2=-42(LC 3)
Max Uplift2=-33(LC 5), 4=-37(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 2 and 4.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.03
(loc)
5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 5=169/0-3-8, 4=17/Mechanical, 3=47/Mechanical
Max Horz 5=106(LC 5)
Max Uplift4=-35(LC 5), 3=-63(LC 5)
Max Grav 5=169(LC 1), 4=35(LC 2), 3=47(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.55
0.42
0.71
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.28
0.02
(loc)
7-9
7-9
7
l/defl
>999
>879
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 131 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-10
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 11=932/0-3-8, 7=932/0-3-8
Max Horz 11=369(LC 4)
Max Uplift11=-106(LC 6), 7=-106(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-740/247, 3-4=-452/240, 4-5=-740/247
BOT CHORD 10-11=-258/480, 9-10=-108/451, 7-9=-58/480
WEBS 2-11=-710/133, 5-7=-709/134
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 11 and 7.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0-7-0
11-0-0
12.00 12
Plate Offsets (X,Y): [1:0-4-12,Edge], [3:0-3-12,0-2-12], [4:0-3-8,Edge], [7:0-1-9,0-1-9], [12:0-3-8,0-5-0], [13:0-3-8,0-5-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.89
0.97
0.72
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.27
0.07
(loc)
9-11
9-11
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 347 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
3-4: 2 X 6 SPF No.2, 5-8: 2 X 4 SYP 2400F 2.0E
BOT CHORD 2 X 6 SYP No.1
WEBS 2 X 4 SPF No.2 *Except*
2-13: 2 X 4 SPF Stud, 1-14: 2 X 6 SPF No.2
WEDGE
Right: 2 X 12 SYP No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-7-7 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 14=9548/0-5-10 (input: 0-3-8), 7=10066/0-5-15 (input: 0-3-8)
Max Horz 14=-372(LC 3)
Max Uplift14=-1491(LC 5), 7=-1663(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-8821/1430, 2-3=-7493/1331, 3-4=-5548/1063, 4-6=-7859/1378, 6-7=-11357/1806,
1-14=-8229/1309
BOT CHORD 13-14=-449/898, 12-13=-1078/6141, 11-12=-872/5293, 9-11=-1137/7772, 7-9=-1137/7772
WEBS 2-13=-314/1924, 2-12=-1536/429, 3-12=-760/4171, 3-11=-283/930, 4-11=-891/5144,
6-11=-3343/728, 6-9=-703/4742, 1-13=-841/5576
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc, 2 X 6 - 2 rows at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-6-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) WARNING: Required bearing size at joint(s) 14, 7 greater than input bearing size.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=1491,
7=1663.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) "Nailed" indicates 3-10d or 3-12d common wire toe-nails. For more details refer to MiTek’s ST-TOENAIL Detail.
Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.14
0.09
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.01
(loc)
23
23
22
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 149 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 27-9-8.
(lb) - Max Horz 2=-98(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 34, 35, 36, 37, 38, 39, 40, 41, 32, 30, 29, 28, 27, 26, 25, 24,
22
Max Grav All reactions 250 lb or less at joint(s) 2, 33, 34, 35, 36, 37, 38, 39, 40, 32, 30, 29, 28, 27, 26, 25,
22 except 41=282(LC 9), 24=282(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 2, 34, 35, 36, 37, 38, 39,
40, 41, 32, 30, 29, 28, 27, 26, 25, 24, and 22.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
35-9-8
7-6-11
2-0-8
2-0-8
7-9-12
5-9-4
13-7-0
5-9-4
17-9-4
4-2-4
23-8-6
5-11-2
29-7-9
5-11-2
35-9-8
6-1-15
0-7-8
9-6-2
0-6-0
0-8-0
6.00 12
4.57 12
Plate Offsets (X,Y): [1:0-3-4,0-2-0], [6:0-3-0,0-2-1], [8:0-3-0,0-3-0], [10:0-0-13,0-1-8], [14:0-2-8,0-1-8], [18:0-2-8,0-2-8], [20:0-6-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.63
0.77
0.79
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.32
0.16
(loc)
19-20
19-20
15
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 279 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2 *Except*
18-20,1-20: 2 X 4 SYP No.1, 5-17: 2 X 4 SPF Stud
WEBS 2 X 4 SPF Stud *Except*
6-18,6-16,7-15: 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
6-21: 2 X 4 SPF No.2
SLIDER Left 2 X 3 SPF No.2 2-3-15
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
1 Row at midpt 5-18
WEBS 1 Row at midpt 6-16, 7-15
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 8-6-8 except (jt=length) 1=Mechanical.
(lb) - Max Horz 1=122(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 13, 12, 11 except 15=-287(LC 5),
1=-182(LC 5), 10=-218(LC 9)
Max Grav All reactions 250 lb or less at joint(s) 12, 11, 10 except 15=2077(LC 1),
1=1163(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3736/684, 2-4=-2139/358, 4-5=-1411/269, 5-6=-1347/373, 6-7=-778/243,
7-9=-114/875, 9-10=-156/710
BOT CHORD 19-20=-631/2833, 18-19=-311/1866, 5-18=-340/193, 15-16=0/410, 13-15=-537/168,
12-13=-537/168, 11-12=-537/168, 10-11=-537/168, 1-20=-693/3221
WEBS 2-19=-975/323, 4-19=0/363, 4-18=-809/243, 16-18=0/516, 6-18=-265/996, 6-16=-406/104,
7-16=-8/537, 7-15=-1890/295, 9-15=-416/227, 2-20=-152/1093
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 12, 11 except (jt=lb)
15=287, 1=182, 10=218.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0-6-0
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.15
0.09
0.10
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.01
(loc)
29
29
28
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 224 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
15-42,14-43,13-45,16-41,17-39: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 15-42, 14-43, 16-41
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 36-0-8.
(lb) - Max Horz 2=-124(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 43, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 41, 39, 38, 37, 36,
35, 34, 33, 32, 31, 30, 28
Max Grav All reactions 250 lb or less at joint(s) 2, 42, 43, 45, 46, 47, 48, 49, 50, 51, 52, 53, 41, 39, 38, 37,
36, 35, 34, 33, 32, 31, 28 except 54=296(LC 9), 30=296(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 14-15=-31/253
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 2, 43, 45, 46, 47, 48, 49,
50, 51, 52, 53, 54, 41, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, and 28.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0.33
0.27
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
13
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 96 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 12-13
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 16-8-8.
(lb) - Max Horz 1=339(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 13, 14, 15, 16, 17, 18, 19, 20, 21, 22,
23
Max Grav All reactions 250 lb or less at joint(s) 1, 13, 14, 15, 16, 17, 18, 19, 20,
21, 22 except 23=252(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-289/46, 2-3=-254/14
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 14, 15, 16, 17, 18,
19, 20, 21, 22, 23.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
0.07
0.04
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 7-5-8.
(lb) - Max Horz 1=142(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 6, 7, 8, 9
Max Grav All reactions 250 lb or less at joint(s) 1, 6, 7, 8 except 9=260(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 8, 9.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.63
0.37
0.30
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 78 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud *Except*
6-16: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 10-8-8.
(lb) - Max Horz 20=-275(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-342(LC 3),
12=-329(LC 4), 19=-364(LC 4), 13=-353(LC 3)
Max Grav All reactions 250 lb or less at joint(s) 17, 18, 15, 14 except 20=313(LC 4),
12=301(LC 3), 16=320(LC 6), 19=348(LC 3), 13=338(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-30/256, 5-6=-31/274, 6-7=-31/272, 7-8=-30/254
WEBS 6-16=-303/0
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 20, 12, 17, 18, 19, 15, 14,
and 13.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
This component is to be used in
conjunction with a rigid diaphragm.
This diaphragm must be capable of
transferring roof loads to the ground
with negligible lateral deflections.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
4-1-1
21-0-0
4-4-9
21-10-0
0-10-0
2-6-6
11-0-0
2-6-6
11-0-0
12.00 12
Plate Offsets (X,Y): [4:0-6-4,0-1-12], [5:0-4-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.25
0.12
0.34
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
-0.03
0.01
(loc)
13
13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 154 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
3-14,6-10,2-14,7-10: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-12
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 15=997/0-3-8, 9=988/0-3-8
Max Horz 15=-369(LC 3)
Max Uplift15=-197(LC 5), 9=-331(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-803/211, 3-4=-728/314, 4-5=-443/307, 5-6=-728/341, 6-7=-798/286, 2-15=-947/216,
7-9=-941/293
BOT CHORD 14-15=-354/360, 13-14=-264/494, 12-13=-194/443, 10-12=-120/491
WEBS 6-12=-111/266, 2-14=-65/505, 7-10=-118/501
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 15 and 9.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
8) "Nailed" indicates 3-10d or 3-12d common wire toe-nails. For more details refer to MiTek’s ST-TOENAIL Detail.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-70, 2-4=-70, 4-5=-70, 5-7=-70, 7-8=-70, 9-15=-20
Concentrated Loads (lb)
Vert: 12=3(F) 10=3(F) 16=3(F) 17=3(F) 18=3(F)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.45
0.27
0.29
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 74 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 11-3-0.
(lb) - Max Horz 20=-251(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-222(LC 3), 12=-206(LC 4), 19=-253(LC 4),
13=-241(LC 3)
Max Grav All reactions 250 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except 16=295(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-33/256, 6-7=-33/253
WEBS 6-16=-278/0
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 20, 12, 17, 18, 19, 15, 14,
and 13.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010
24-0-0
0-10-0
1-10-0
11-0-0
0-7-0
11-0-0
12.00 12
Plate Offsets (X,Y): [3:0-0-8,0-1-12], [4:0-4-4,0-1-12], [5:0-6-4,0-1-12], [6:0-3-0,0-3-0], [8:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
25.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.62
0.59
0.34
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.32
0.01
(loc)
20-21
20-21
8
l/defl
>999
>425
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 236 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
7-13: 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud *Except*
24-25,27-28,42-43: 2 X 4 SPF No.2
WEDGE
Right: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-20, 5-18
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 12-2-8 except (jt=length) 21=0-3-8.
(lb) - Max Horz 21=-358(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 13, 21, 8, 11 except 18=-110(LC 6),
19=-120(LC 2), 10=-157(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 17, 16, 14, 12, 11, 10 except
18=555(LC 1), 13=354(LC 1), 21=737(LC 9), 8=271(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-305/209, 3-4=-449/177, 5-7=-322/171, 7-8=-352/73, 2-21=-362/239
BOT CHORD 20-21=-224/346, 19-20=-87/297, 18-19=-87/297
WEBS 3-20=-180/267, 5-20=-113/377, 5-18=-505/48, 7-13=-329/84, 3-21=-347/107
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to uplift at jt(s) 18, 13, 21, 8, 19, 11, and
10.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.
March 4,2010