HomeMy WebLinkAbout0T.201 LIFE SAFETY PLAN.PDF
INNOVATIVE EXERCISE RESEARCH ... SHEET NUMBER SHEET TITLE ARCHITECTCONSTRUCTION DRAWINGS FOR: REVISIONS MARK DATE DESCRIPTION SEAL BROAD RIPPLE DESIGN ASSOCIATES, LLC. AND PRIOR WRITTEN
CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN, AND c COPYRIGHT 2010 JAMES R. STUTZMAN, AIA, INDIANAPOLIS BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, BUILDING
OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS OR THE RESULTING ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS
SUBMISSION AND THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC RIPPLE DESIGN ASSOCIATES, LLC. RIGHTS
OR OTHER RESERVED RIGHTS. UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND BROAD OF THE ARCHITECT AND BROAD RIPPLE DESIGN ASSOCIATES, LLC. COPYRIGHT & OWNERSHIP OF DOCUMENTS
260 1st AVE. SW CARMEL, IN 46032 EVAN J. DENIS DRAWN BY: T.201 LIFE SAFETY PLAN ACCESABLE ROUTE ACCESABLE ROUTE ACCESABLE ROUTE PARKING 3RD ST. SW 1ST AVE. SW PARKING EXIT TRAVEL= 81'-0"
EXIT TRAVEL= 70'-0" 6554 SQ. FT. EGRESS NEW CONNECTING WALK EGRESS VEST. EXISTING RAMP GROSS SQ. FT. A: 6,553.98 sq ft SCALE: 1/8" = 1'-0" 1 LIFE SAFETY PLAN INNOVATIVE EXERCISE CODE
RESEARCH APPLICABLE BUILDING CODES General Administrative Rules (675 IAC 12) !2006 Edition Indiana Building Code (IBC 2006) !2008 Edition Indiana Building Code -Accessibility (ICC/ANSI
A117.1-2003) !2008 Edition Indiana Building Code -Structural (ASCE 7-2005) !2008 Edition Indiana Plumbing Code (UPC 1997) !1999 Edition Indiana Electrical Code (NFPA 70-2008) !2009 Edition
Indiana Mechanical Code (IMC 2006) !2008 Edition Indiana Fuel Gas Code (IFGC 2006) !2008 Edition OCCUPANCY GROUP Group B-Business Group for Clinic (Outpatient); Professional Services;
Training/Skill Development per IBC 304.1 CONSTRUCTION TYPE Construction Type V-B Existing Construction; Exterior walls concrete masonry; Unprotected pre-engineered steel structure; wood
stud furring; New Construction: Interior partitions of non-rated wood stud and drywall BUILDING AREAS Allowable !Occupancy Group B; Type V-B Construction (IBC Table 503) !9,000 square
feet Actual !Interior Area of Exercise Room 1 !1,604 net square feet !Interior Area of Exercise Room 2 !1,379 net square feet !Exam, Waiting & Office Area !3,017 net square feet !Actual
gross building area (exterior face of walls) !6,554 gross square feet OCCUPANT LOADING Interior Area of Exercise Room 1 (50 @1,604 square feet) !32 persons Interior Area of Exercise
Room 2 (50 @1,379 square feet) !28 persons Exam, Waiting & Office Area (100 gross @3,017 square feet) !31 persons Total Building Occupant Load !91 persons EGRESS REQUIREMENTS Two means
of egress required per IBC Table 1019.1 All exit doors to be provided with illuminated exit signs per IBC 1011.1 1011.1 All exit doors to be illuminated per IBC 1006.1 ACCESSIBILITY
REQUIREMENTS All existing restrooms to meet ICC/ANSI A117.1-2003; Chapter 6 Front entry at grade. Threshold height meeting ICC/ANSI A117.1-2003 MINIMUM PLUMBING FIXTURES Water Closets:
1 per 25 occupants: (minimum) !4 required Lavatories: 1 per 40 occupants: (minimum) !3 required !Distribution:! ! !Men: !1 water closet & 1 urinal; or ! ! !2 water closets ! ! !2 lavs
(recommended) 1 (minimum) ! !Women !2 water closets ! ! !2 lavs Drinking Fountain: 1 per 100 occupants (ANSI A117.1 hi/lo type) !1 required 660 east 62nd. street indianapolis, indiana
46220-1870 (phone) 317.251.0533 (fax) 317.255.2885 brda a r c h i t e c t s w w w b r o a d r i p p l e d e s i g n c o m b r o a d r i p p l e d e s i g n a s s o c i a t e s, L.L.C.