Loading...
HomeMy WebLinkAbout05010007 1799 Halifax VOWC pg. 2.20AREA FIRST FLOOR 2705 SECOND FLOOR 1051 TOTAL 3756 PARTIAL BASEMENT 2380 FULL BASEXAT 2781 GARAGE 647 PORCH 'A, 218 PORCH 8, '0' 81 PORCH 100 PORCH 68 DBL WINDOW WALL DE SCALE 1/4' 1'-0' (WINDOW R.O. PER SPEC) SCALE 1/4" 1' -0" SEE PLAN FOR HEADER SIZE 16d NAILS PER STUD T. 2x4 PLATE 1 6d NAILS 12" OC. AT EACH HEADER MENDER (WINDOW R.O. PER SPEC) BOTTOM PLATE CO 0 NOTE FASTEN EACH PLATE TO EACH HEADER PLY W/ 16d COMMON NAILS AT 12' 0.C. NAIL FIRST ADJACENT KING TO EACH PLATE AND HEADER PLY WITH 2 -16d COMMON NAILS, TYPICAL -SEE PLAN FOR TRIM STUD REQUIREMENTS 17' -8" OPT. BEDROOM 4 OPTIONAL BEDROOM CONVERSION 216 i I 42' KNEEWALL PER CODE 3' -4» 2' -7 1/4 (-0 1/2" 3' -9 1/2 PELLA -2 --3359 FIX WS -23660 FIX RREBIDCWIG AS REQ'D 4-2x4 1R /1S 4' -5 1/2" OPEN TO BELOW BEDROOM 2 6 -V 0.G 7280 ARCH TOP 1R94 PRE ENGINEERED WOOD ROOF TRUSSES 0 24" O.C. MAX. PROVIDE BACKING FOR HANDRAIL (-5 1/2 PEU.A --2 -3359 FIX WS-2-3660 FIX OPEN TO BELOW 1- -31/2" 42" KNEEWALL PER CODE 5 1/2" (--7" 12" DROP HDR 20' -0 1/2" 1N -WALL GIRO TRUSS 8' -O' C G. BEDROOM 3 Bd ¢4 SECOND FLOOR PLAN SCALE 1/4' NOTE ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD. ALL STUDS ARE 3 1/2' UNLESS NOTED. All DIMENSIONS PRESENTED HERE ARE FRAME MEWS ONLY SEE SHT.1.1 FOR FOUNDATION FOOTPRINT. REVIEW ALL WINDOW HDR HEIGHTS PER PLATE HT. AND VERIFY W/ ELEVATIONS AND CORNICE DETAILS NOTES 1. ALL CASED OPENINGS GREATER THAN 48" MADE HOLD HEADER TIGHT TO PLATE Z ALL 81 -FOLD DOORS R.O.'S 1 1/2 WIDER THAN DOORS HEADER HT. 82" AFF 3. ALL Bi -PASS DOORS R.O.'S 1' WIDER THAN DOOR HEADER HT 83" AFF 4. TOWEL BARS (T8) OVER CABINETS AND TOILETS BLOCKING TO BE 55 AFF TO CL 5. TOWEL BARS CO NOT OVER CABINETS AND TOILETS BLOCKING TO BE 39 AFF TO CL 6. BLOCKING FOR TISSUE HOLDERS (TH) TO BE 24 AFT 7. HEADERS OVER 48" LONG REQUIRE DOUBLE CRIPPLE 8. DENOTES LOCATION OF WALL BRACING. WAILS NOT NOTED IN THIS MANNER SHALL BE BRACED IN ACCORDANCE WITH IRC SECTION 8602.10 AND TABLE R602.10.3. NOTE: CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AU. DIMENSIONS AFFECTING CONTRACTOR'S PRODUCTS. INSTAL ATIONS OR FABRICATIONS IN THE FIELD PRIO R TO EXPEDITING DIE CONSTRUCTION OF SUCH %OR C ERRORS AND OMISSIONS t'rtiICH MAY OCCUR IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF 1)HE NOTE: WINDOWS SHOW BOTH PELLA PRO-LINE AND WEATHERSHIELD WINDOW RO.S ARCHITECT, IN WRITING, AND YRITIEN INSTRUCTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL BE HEED RESPONSIBLE FOR ANY ERRORS, DISCREPANCIES OR OMISSIONS FOR Weil 111E CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO CONS1RUC110N AND /OR FABRICATION OF THE Mk Field verify all dimensions DO N DRA W I NGS! NOTES: SEE ELEVATION DRAVI1NGS FOR STRUCTURAL WAIL SHEATHING LOCATIONS AND REQUIR TENTS ROOF SHEATHING SPECIFICATION: 7/16' THICK STRUCTURAL WRING (24/16 SPAN RATING) FASTEN %ITH 8d COMMON NAILS SPACED 6' AT PANEL EDGES AND It AT INTERMEDIATE SUPPORTS. a) CI Pi x r Pti .94 1*** 0 44 0 4.4 U) 7 d Cn X '94 g w Q COPYRIGHT 2002 PULTE HOME CORPORATION DRAWN 8Y: Midwest Arch Dept DATE: 01 -05 -2004 REV No. DATE COMMUNITY-SPEC LEVEL Village of West Clay Level 5 GARAGE LEFT PLAN Name No. Crestview 37 3756—IN—Lev4-220 SHEET No. 2.20