HomeMy WebLinkAbout04100007-10, 13, & 15 KFC & Lohn John Silvers - Site Details - C2.2rr Iry 6 e N.T.S. N.T.S. N.T.S. N.T.S. 17 18 19 20 NOSE DOWN TO FINISH GRADE CURB TAPER NOT USED NOT USED NOT USED ita Zn C-0" TYPE 1 11111111 TYPE 2 TYPICAL ELEVATION STD. 6" CURB DRIVEWAY SURFACE N.T.S. N.T.S. N.T.S. N.T.S. 14 15 6 CONCRETE CURB, AS DETAILED ELSEWHERE NOTF crF P1 tql tr A T±r” "ADA: A PF.7.C.ILIRCE GUIDE" FOR PEFEPENCES ACCESSIBLE (HANDICAP) RAMPS: GENERAL: PROVIDE RAMPS WHEN REQUIRED WITH SLOPE BETWEEN 1: 20 (MINIMUM) TO 1:12 (MAXIMUM). USE THE LEAST POSSIBLE SLOPE FOR ANY REQUIRED RAMP. (REFERENCE: 4.8) A. MINIMUM CLEAR WIDTH OF RAMP SHALL BE 36". (REFERENCE: 4.8.3) B. LANDINGS SHALL BE AT LEAST AS WIDE AS THE RAMP RUN LEADING TO IT AND SHALL BE A MINIMUM OF 60 IN. CLEAR IN LENGTH. (REFERENCE: 4.8.4) C. NOWHERE SHALL THE CROSS SLOPE OF AN ACCESSIBLE ROUTE EXCEED 1:50 (2 PERCENT IN ANY DIRECTION). (REFERENCE: 4.3.7) D. E. PROVIDE DETECTABLE WARNINGS ON PAVEMENT AND WALKING SURFACES WITH AT LEAST 70 PERCENT CONTRAST WHERE INDICATED ON SITE PLAN OR AS DIRECTED BY C.E. EXTEND WARNING SURFACE THE FULL WIDTH AND DEPTH OF RAMP AND WALKING SURFACE WHERE REQUIRED. A -4'574 .4, B. c. D. A. FINISHED SURFACES SHALL BE SLIP-RESISTANT (MEDIUM BROOM FINISH OR EQUIVALENT, UNLESS OTHERWISE INDICATED ON SITE PLAN). (REFERENCE: 4.5.1) APPROVED DETECTABLE WARNING SURFACE AS FOLLOWS: 1. FINISH: BROOM FINISH OVER SCORED JOINTS. 2. COLOR: TRAFFIC YELLOW OR BLUE EITHER INTEGRAL COLOR OR SURFACE APPLIED COLOR HARDNER TYPE AS RECOMMENDED BY MANUFACTURER TO MATCH COLOR #33538 PER FEDERAL STANDARD #595A. 3. SURFACE APPLIED COLOR HARDNER: HEAVY DUTY TYPE AS RECOMMENDED BY SYSTEMS MANUFACTURER. e."1 531... TYPE A OBLIQUE VIEW *NOTE: IF RAMP IS ADJACENT TO WALKWAY INSTEAD OF LAWN AS SHOWN ABOVE, THEN SIDE FLARES SHALL BE 6 IN LIEU OF 12. 6" CONCRETE CURB AS DETAILED ELSEWHERE, FLUSH WITH PAVEMENT PAVEMENT AS DETAILED ELSEWHERE TYPE B OBLIQUE VIEW ACCESSIBLE (HANDICAP) PARKING SPACES: PROVIDE ACCESSIBLE PARKING SPACES PER ITEM #2 THIS SHEET. PROVIDE ONE VAN-ACCESSIBLE PARKING SPACE IN EVERY 8 ACCESSIBLE PARKING SPACES REQUIRED, BUT NOT LESS THAN ONE PER SITE AS FOLLOWS. ACCESSIBLE PARKING „SPACES REQUIRED: MINIMUM 96 INCHES WIDE WITH A MINIMUM VERTICAL CLEARANCE OF 114 INCHES (IF POSSIBLE) AND LOCATED (IF POSSIBLE) ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL FROM (ADJACENT) PARKING TO AN (ACCESSIBLE) ENTRANCE. SEE FIGURES #1 #2 THIS SHEET. PROVIDE 60 INCHES MINIMUM ACCESS AISLE ADJACENT TO PARKING SPACE. VAN-ACCESSIBLE PARKING SPACE: MINIMUM 96 INCHES WIDE WITH A MINIMUM VERTICAL CLEARANCE OF 114 INCHES (IF POSSIBLE) AND LOCATED (IF POSSIBLE) ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL FROM (ADJACENT) PARKING TO AN (ACCESSIBLE) ENTRANCE. PROVIDE 96 INCHES MINIMUM ACCESS AISLE ADJACENT TO PARKING SPACE IF ONLY ONE IS REQUIRED OR BETWEEN ACCESSIBLE AND VAN-ACCESSIBLE PARKING SPACE. SEE FIGURES #1 #2 THIS SHEET. SIGNAGE: PROVIDE A MOUNTED SIGN SHOWING THE INTERNATIONAL ACCESSIBILITY SYMBOL AT ALL ACCESSIBLE PARKING SPACES. PROVIDE AN ADDITIONAL SIGN, MOUNTED BELOW THE ACCESSIBILITY SYMBOL THAT READS "VAN-ACCESSIBLE" FOR VAN-ACCESSIBLE PARKING SPACES. LOCATE SIGNAGE SO AS NOT TO BE OBSCURED BY A PARKED VEHICLE. SEE ITEMS #1, #2, #3, AND #4 THIS SHEET. 02580 PAVEMENT MARKING MARKING (STRIPING) PAINT FOR PARKING SPACES, TRAFFIC ARROWS, HANDICAP PARKING AND SYMBOLS, ETC., PER ASTM-P -7B-66T STANDARDS AND AS FOLLOWS: 5. PAINT HANDICAP SYMBOLS AND HANDICAP ACCESS RAMPS Pt CIE. 16 ADA COMPLIANCE SPECIFICATION WHITACRE GREER PAVERS WITH DETECTABLE WARNING SURFACE, COLOR 30, INSTALLED ON A 1/2" DEEP LATEX MODIFIED CEMENT MORTAR SETTING BED. SLOPE PER DETAIL ABOVE TO FRONT EDGE OF CURB 46 XTJ1T1 I H, 1_111 III t!!! I I c !II 111 li: I Ili-- 2 TYPICAL RAMP SECTION A-A 1. NEW SURFACES: RUBBER BASE TYPE (CHLORINATED RUBBER) TO MEET FEDERAL SPECIFICATION TTP-115. 2. EXISTING SURFACES WITHOUT ANY SEAL COATING: OIL BASE (ALKYD RESIN TYPE TO MEET FEDERAL SPECIFICATION TTP- 85. 3. NEW OR EXISTING SURFACES WITH A TOP COATING OR SEAL COATING (USUALLY WATER BASE): WATER PASE TYPE TO WET FEDERAL SPECIFICATION TTP-( 4. PROVIDE A NON-SLIP AGGREGATE *ADDITIVE TO MARKING PAINT USED AT HANDICAP ACCESS RAMPS. APPLY 2 COATS WITH STRAIGHT EDGES, YELLOW EXCL MATCH ADJACINT OR EVITINO COLOR WHEN THE PAVING IS AN EXPANSION OR SEGMENT OF A LARGER LOT. t7 .7•" ...111111111.0011141.' /10.110 CONCRETE WALKWAY CONSTRUCTION, AS DETAILED ELSEWHERE 1. INTERNATIONAL HANDICAP SYMBOL: 2. "ADA" REGULATIONS FOR NUMBER OF PARKING SPACES: 3. UNIVERSAL PARKING SPACE DESIGN (FOR MORE THAN ONE STALL): 4. SINGLE *VAN-ACCESSIBLE SPACE: 5. COMPONENTS OF A SINGLE RAMP RUN NOTE THAT IN 7111S CASE ALL SPACES ARE "VAN-ACCESSIBLE" LLJ TOTAL PARKING IN LOT 1 TO 25 26 TO 50 51 TO 75 76 TO 100 SLOPE REGULAR STALLS LEVEL LANDING CONC. SIDEWALK 0 REGULAR STALLS 4•1111.1.1.■■• -•■•••••11.- 8'-0" 1:16 TO 1:20 30 760 8 EJ 96" 26:d MIN. MIN. REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES 1 .2 8'-0" MIN. MIN. MIN. MIN. FIGURE #1 FIGURE #2 SURFACE OF RAMP HORIZ. PROJECTION OR RUN MAXIMUM RISE IN MM 1:12 TO 1:16 30 760 30 40 3 4 PLEASE NOTE IF ONLY ONE HANDICAP SPACE IS PROVIDED ON SITE, THEN THAT SPACE MUST BE DESIGNATED AS "VAN-ACCESSIBLE" AND SHALL COMPLY FULLY WITH NUMBER 4 BELOW SIGN W/ INTERNATIONAL SYMBOL OF ACCESSIBIUTY LOCATED FOR UNOBSTRUCTED VIEW NOTE: AN ADDITIONAL SIGN READING: "VAN-ACCESSIBLE" SHALL ALSO BE MOUNTED SO AS NOT TO BE OBSCURED BY A PARKED VEHICLE. 8'-0" 8'-0" MIN. CONC. SIDEWALK PLEASE_NOTE: HANDICAP RAMPS AS REQUIRED BY "ADA" REGULATIONS CANNOT BE LOCATED WITHIN THE SPACE DENOTED AS "ACCESS AISLE" AS NOTED ON FIGURES 1 AND 2 ABOVE. REQUIRED ACCESS AISLE REGULAR STALLS PLEASE NOTE: HANDICAP RAMPS AS REQUIRED BY "ADA" REGULATIONS CANNOT BE LOCATED WITHIN THE SPACE DENOTED AS "ACCESS AISLE" AS NOTED ON FIGURE 1 ABOVE AND FIGURE 2 BELOW. SIGN W/ INTERNATIONAL SYMBOL OF ACCESSIBILITY LOCATED FOR UNOBSTRUCTED VIEW NOTE: AN ADDITIONAL SIGN READING: "VAN-ACCESSIBLE" SHALL ALSO BE MOUNTED SO AS NOT TO BE OBSCURED BY A PARKED VEHICLE. REQUIRED ACCESS AISLE REGULAR STALLS LEVEL LANDING FIGURE #3 (REPRINT OF ADA A RESOURCE GUIDE; SECTION 4.8, F1G. 16) 9 12 MAXIMUM HORIZONTAL PROJECTION FT M N.T.S. 4 PI OT DATE: CON TRAC I DAT E BUILDING TYPE: P1 AN VIT1SION. SITE NUMBER. STORT NUMB1_11 3 r- Ln m t 0 (f) c 0 (f) 0 0 C.) 9 t" (3 0 tr x 0 0 6 KFC LJS 0 owiti4iflii V N r 5 4 01,, ..a T k 5 6, 0 ;;;(4'TE iT)F „Z. 1331 S. RANGFI INI ROAD CARMEL IN 46032 KL60-y04 SITE DETAILS 0' h.! XX XX.XX KI _60-W4 Jan044 12-XXXX 2004087 05 .4 0827.04 1