Loading...
HomeMy WebLinkAbout04100024 ADLS Amend Goddard School Lighting - Site Photometric PlanSTATISTICS DESCRIPTION AVG MAX MIN MAX /MIN AVG /MIN SITE 0.6 fc 5.8 fc 0.0 fc N A N A PARKING LOT 1.6 fc 5.0 fc 0.2 fc 25.0:1 8.2:1 r LUMINAIRE SCHEDULE SYMBOL LABEL Q TY CATALOG N UMBER DESCRIPTION LAMP FILE LUMENS LLF WATTS A 1 AVA- 3 -250MH CLEAR FLAT GLASS LENS CLEAR 250 MH /HOR PRORATED TO 1000 LUMENS AVA325M.ies 23000 0.72 295 C 1 AVA— F- 250MH —HS CLEAR FLAT GLASS LENS CLEAR 250 MH /HOR PRORATED TO 1000 LUMENS AVAF25MS.ies 23000 0.72 295 =I D 1 AVA- 3- 250MH —HS CLEAR FLAT GLASS LENS CLEAR 250 MH /HOR PRORATED TO 1000 LUMENS AVA325MS.ies 23000 0.72 295 mil r D, ET, I0 ;N F-r i; s ot1111II,, t, O N PE910337 r STATE OF YD IA NP.•; �,w e,, F S S /ONAL° SNS ei llitI111t DATE: D EF It r DWN BY: A C H CHKD. BY: JMP SCALE: 1 2 0' DATE: 01-27-2003 PROJECT NUMBER 02-123 DESIGN PHASE CONSTRUCTION PLAN NUMBER C6.O UTILITY STATEMENT: The underground utilities shown have been located from field survey information and existing drawings. The surveyor makes no guarantees that the underground utilities comprise all such utilities in the area, either in— service or abandoned. The surveyor further does not warrant that the underground utilities shown are in the exact location indicated although the surveyor does certify that they are located as accurately as possible from information available. The surveyor has not physically located the underground utilities. CAUTION THE LOCATIONS OF ALL EXISTING UNDERGROUND UTUTIES SHOWN ON THIS DRAWING ARE BASED ON ABOVE GROUND EVIDENCE OR INFORMATION GATHERED DURING THE FIELD SURVEY PORTION OF THIS PROJECT. AS SUCH, THIS INFORMATION IS SPECULATIVE IN NATURE ONLY AND SHOULD NOT BE CONSTRUED AS FACT. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTIUES FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF THE UNDERGROUND UTIUTIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF ANY AND ALL CONSTRUCTION. 1 -BOO -352 5544 CALL TOLL FREE 64 TIE REBAR 4 #5 REBAR 3R. CU. GROUND WIRE VICINITY MAP NOT TO SCALE 2" CLEARANCE TYP. 12" O.C. #4 TIE REBAR 12" O.C. NORTH r I L. II II iI I ir` J I Il am 1 I II 2' -0" l LIGHT POLE FOUNDATION o` NOT TO SCALE C 3 INLET RACEWAYS OF 2" CONTINUOUS CONDUIT 4-1"x36" ANCHOR RODS BOLT CIRCLE CONFIGURATION BY LIGHT MANUFACTURER 3" CLEARANCE FINISH PAVING Il 4 #5 REBAR 4" CLEARANCE i DETAIL OF COIL COIL TO BE OF #6 COPPER WIRE APPROXIMATELY 0' LONG PLACE FELT BETWEEN CONCRETE AND COIL TO PREVENT BONDING i a a a J 4 J• �i k �o �O .o� o so. A woods V CV g IE so° o o �o• 0 0 O 'O- o e 0 ,69f 'O' so. o 'o. 'O- 0 0 o o .o• o s p. o sO O 'o' 'Oo .o. o o so- rass) x1 concrete- mound 1 a I 1 X x x x r- X X X X X X X X X NORTH 20 0 10 20 IN FEET 1 inch 20 ft.