Loading...
HomeMy WebLinkAbout0003.99 Miscellaneous805-807.2 TABLE 8-A, TABLE 8-B 1997 UNIFORM BUILDING CODE 2: The textile wall covering. shall meet the acceptance criteria of UBC,Standard 842 when tested using a product mounting sys- tem, including adhesive, representative of actual use.. SECTION 806 — INSULATION Thermal and acoustical insulation installed on walls or ceilings shall comply with Section 707. 807.1 Floors and Walls in Water Closet Compartment and Showers. 807.1.1 Floors. In other than dwelling Units, toilet room floors shall have a smooth, hard nonabsorbent surface such as pordand cement, concrete, ceramietile. or other approved material that ex- tends upward onto the walls at least 5 inches (127 n1m): 807.1.2 Walls. Walls within 2 feet (610 n1m) of..thefront and sines of urinals and water closets shall have a smooth, hard non - absorbent surface of portland cement, concrete, ceramic the or other smooth, hard nonabscrbent surface to a height of feet (1219 mm),and except for structural elements, the materials used in such walls shall'be of a type that is not adversely affected by moisture. See Section 25126r other limitations. EXCEPTIONS: 1. Dwelling units and guest rooms. 2. Toilet rooms that are not accessible to the public and that have not more than one water closet. In all occupancies, accessories such as grab bars! towel bars, pa- per dispensers and soap dishes. provided on or within walls, shall be installed and sealer) to protect structural elements from mois- ture. 807.1.3 Showers. Showers in all occupancies shall be finished as specified in Sections 807.1.1 and 807.1.2 to a height of not less than 70 inches (078 mm) above the drain inlet. Materials other than structural elementsusedinsuch -walls shall be of a type that is not adversely affected by moisture. See Section 2512 for other limitations. 807.1.4 Shower doors. For shower doors, see Sections 2406.4 and 2407. 807.2 Water Closet Room Separation. See Section 302.6 for requirements to separate water closet rooms. /fie Clods /ricer✓ iCQ C!J G Ps90C S idJ�� drOY/d7Q�aS7fi�� CPS �lH is t/le �rBZGic� t`o/l:/ens �u-/ir TABLE6-A— FLAME-SP.RcEAyD 8CLASSIFICATION �ra,.c die a�%ems'• f�/ ,MATERIAL DIIGI IFIFn wN TABLE 8-B—MAXIMUM FLAME -SPREAD CLASSI OCCUPANCY GROUP ENCLOSED VERTICAL EXITWAYS OTHER E%ITWAYSi ROOMS OR AREAS A II 113 B I III E I II F If III III R I II 1114 1 15 _ IIh 1-3 1 M I III R-I I III R-3 111 III IIIT S-I. S-2 - II II 111 S-3, S-4, S-5 I II III U NO RESTRICTIONS roam plastics shall comply with the requirements specified in Section 2602. Carpeting on ceilings and textile wall coverings shall comply with the requirements specified in Sections 8042 and 805, respectively. '-Finish classification is not applicable lu interior walls and ceilings of exlerior exit access balconies. xln Group A, Divisions 3 and 4 Occupancies, Class III may be used. aOver two stories shall be of Class H. - 51n'Group l, Divisions land 3 Occupancies, Class II may be used. 6Class III may be used in administrative spaces. 711ame-spread provisions are not applicable to kitchens and bathrooms or Group R. Division 3 Occupancies. 1-92