Loading...
HomeMy WebLinkAboutL102 Planting PlanLANDSCAPE NOTES 1. All planting beds are to incorporate Dewitt Weed Barrier, or equivalent, between a minimum of three inches of shredded hardwood mulch and a minimum of six inches of topsoil or planting mix. An approved pre-emergent herbicide shall be applied in all planting beds before and after mulching at rates specified by the manufacturer. 2. All soil in designated planting areas to be loosened to depth of 6 inches prior to planting. 3. It is the landscape contractor's responsibility to provide and verify that the topsoil in the planting areas is not over compacted and is reasonably free from subsoil, stones, downed timber, brush, roots, stumps, rubbish, broken concrete, and any other material that may impede the establishment of the proposed plant material. 4. All trees and evergreen plant material to be balled and buriapped, unless otherwise noted. 5. All shrubs may either be container grown, or balled and burlapped. 6. The landscape contractor shall supply all plant material in quantities sufficient to complete all plantings shown on the drawings. If quantities of plant materials shown on the drawings conflicts with quantities given on the plant list, the quantities shown on the drawings shall supersede the 7 las eviction from the project specifications effecting the health, handling, fertilization, ma inte and general condition of the specified plant material must be presented to the owner in written format for approval prior to execution. The landscape contractor shall assume full responsibility and associated cost for all changes made without proper approval. 8, All plant material to be planted at the same relative depth as before transplanted. 9. Flood all plants twice during the first twenty-four hour period after planting. 10. Begin maintenance immediately after planting and continue until final acceptance. 11. All plant material shall be guaranteed for one full year from date of acceptance. 12. All plants to be guaranteed and maintained to be in healthy condition for one full year after acceptance of all planting. 13, All new planting material shall meet or exceed (ASNS) American Standards for Nursery Stock Specifications of Quality. 14. All proposed plant materials are shown at 3/4 mature growth. Space as indicated on plant list or to proper horticultural methods. 15. Tree caliper size indicates the diameter of the trunk taken at 6 inches above ground level or top of 16. All planting bed lines are to have a cleared spade cut edge to a minimum depth of 4 inches. root ball. 17. Keep the soil of all balled and container plants moist until they are planted, If plants cannot be planted immediately, they should be heeled in and balls /containers should be covered with mulch. The location of a designated landscape material staging area shall be determined by both the landscape contractor and the owners on site representative. 18. The landscape contractor shall coordinate all finish grading of all lawn areas with the general contractor and owner prior to beginning any final grading work. A minimum of 4" inches topsoil shall be provided over all lawn areas receiving seed or sod. All work shall be in accordance with the Project Specifications Section 02900 and 02930. 19. Contact all Utility Companies to locate all mains, conduits, service lines, etc., in the affected construction area. 20. The location and protection of utility structures and facilities, their support and maintenance during landscape construction (in cooperation with applicable utility) is the expressed responsibility of the landscape contractor. 21. The landscape contractor is responsible for coordinating and scheduling the landscape installation with other site work to assure proper placement of plant materials and other landscaping. TOP OF BANK OF POND Plant Type Deciduous Shrubs and Grasses Evergree Shrubs Deciduous Trees Ornamental Trees EFC PLANT MATERIAL M chlino Soo Sheet 1101 M tchbne Soo Shoot L102 Key Number Size AA 3 #5 CS 84 #3 PFA 140 #3 PF 35 #3 SB 92 #3 SJ 58 #3 VP 80 #5 BS 588 18" JC 139 #5 JS 44 #5 IG 140 #5 IM 89 #5 IV 362 #5 TMD 209 18 -24" FG 12 2.5" ACS 27 2.5" TD 8 8' GT 25 2.5" QR 20 2.5" GB 35 2" QB 37 2.5" TA 18 2.5" TT 16 2.5" UP 12 2.5" AS 2 6' cl. AG 32 1.5" CK 7 1.5" MQ 9 1.5" PS 8 1.5" SR 17 1.5" SCHEDULE Space to Proper Horticultural Methods Botanical Name Aronia a. 'Brilliantissima' Cornus s. `Isanti' Itea v. `Sprich' Ligustrum x vicaryi Spiraea j. `Neon Flash' Spiraea j. `Goldmound' Viburnum plicatum `tomentosum' Buxus x k `Green Velvet' Juniperus c. `Sea Green' Juniperus Scopulorum Ilex x Glabra `Nordic' Ilex x. meserveae `Blue Girl' Ilex verticillata Taxus media `Densiformis' Fagus grandifolia Acer saccharum Taxodium distic!Lm Gleditsia t. `Inermis' Quercus rubra Ginkgo biloba Quercus bicolor Ulmus x `Morton' Quercus x `Long' Ulmus x Allee' Amelanchier Arborea `Springtime' Amelanchier x grandiflor Cornus Kousa Magnolia x. quimquepeta `Galaxy' Prunus serrulata `Kwanzan' Syringa Reticulata Euonymus f. 'Colorata' Common Name Red Chokeberry Isanti Dogwood Little Henry Dwarf Sweetspire Golden Vicary Privet Neon Flash Spirea Goldmound Spirea Doublefile Viburnum Green Velvet Boxwood Sea Green Juniper Skyrocket Juniper Nordic Inkberry Blue Girl Holly Winterberry Dense Spreading Yew American Beech Sugar Maple Bald Cypress Thornless Honeylocust Red Oak Ginkgo Swamp White Oak Accolade Elm Regal Prince Oak Allee Elm Shadblow Serviceberry Autumn Brilliance Serviceberry Kousa Dogwood Galaxy Magnolia Kwanzan Cherry Japanese Tree Lilac Purpleaf Wintercreeper Remarks Ali Plant Selections Shall Be Of Locally Grown Plant Material. All Plant Material Shall Be Of Comparable Size and Shape. All Plant Material Shall Have Uniform Branching Providing For Consistent Shape And Free Of Bare Spots. Trees 5" Cal. Or Larger No •Stoking Required Under 5" Cal. Min. Evergreen Tree Planting Section (Not To Scale) Plan View (Not To Scale) 1 l 1 (s ,s Tree Planting Section (Not To Scale) Planting Mixture Planting Mixture t..� ��.l� Vii:. °;iF�.: pit 6" Min. Shrub .Planting Section (Not To Scale) Plant Trees With Root Flare at Grade Level 3 Shredded Hardwood Mulch Do Not Pile Mulch on Tree Trunk Remove All Wire, Strings And Burlap From Top Of Ball Finish Grade, Plant Tree 6" Higher Than Grade 4" High Compacted Saucer Slow Release Fertilizer Tablets Per Manufacturer's Recommendations Compacted Saucer 3" Mulch Bed Top Of Root Bali 7' Stake locate One Stake Directly Sw Of Tree Tree Trunk Reinforced Rubber Hose #10 Wire Note: Remove Wires and Stakes After One Year 3 Reinforced Rubber Hose Sections With Double Strand Of #10 Wire Wrap `7 0 Double Strand Wire At Least Twice Around Each Post Wra Tree From Bottom Up With 5070 Overlap And Tie Securely Plant Trees With Root Flare at Grade Level 3" Shredded Hardwood Mulch Do Not Pile Mulch on Tree Trunk Remove All Wire, Strings And Burlap From Top Of Ball Finish Grade, Plant Tree 6" Higher Than Grade 6" High Compacted Saucer Slow Release Fertilizer Tablets Per Manufacturer's Recommendations Plant Shrub With Root Flare at Grade Level 3" Shredded Hardwood Mulch Do Not Pile Mulch on Shrub Stem Remove All Wire, Strings And Burlap From Top Of Ball Finish Grade 4" High Compacted Saucer t Slow Release Fertilizer Tablets Per Manufacturer's Recommendations Planting Mixture DON'T DIG BLIND NORTH 1-800-382-6644 WI ICU rri 1 -800- 428 -6200 FOR MIS OUTME OF INDIANA SLUE =MKS OF ML D STwO UNDERCPC00 UT IMS SNOW OH rtes IiM ARE i!A*iD UPON ADO* CREW MEE {k a but eo�4 manholes, Nat uarati awl mob moa�Zpaa grant by TIM M1 ARE SFECLIATE ki NATURE. T> E I,LAT ALSO L E OM =NO IAOOtaIala MIS FOR wat T I IS No 14801E ORCUO E4DC110E CR FOR MICR No AOWE CROUHF Meet RAS CESMO,. TIE WET LOCXDONS OF SAO COSTING ttlbtRCROUO U111I15 MED of 4i •ID eT TIE OOHtRACTt r"Cil To A 2 W+SZEIT,,. Darn ep Moiled Br co o) N 0 l (0 d- p 0 a Qi o t` a ce Z •L 0 j N .S a N a N rL r- T-Q cj 5 co w cr) `q4� Q���s i (n PE19900458 sTATE aF r o yA FGR KLC PED sco,ec t• L102 1/3/05 r ProJed Humber 020350 -20200 1- CD CD N X 0 o� oz o a. o 0