Loading...
HomeMy WebLinkAbout961.98 Weston Shoppes - Foundation Details F2.1DRAWING REVIEW ISM! A MAI' 28, laclb A A A BUILDING AOENCY SUFSIITTAL MAY 2/1), 14e115 CONSTRUCTION Ellb/ISSUE_ A A 46. A 1412 VM ectem same MN Pita SCALE OWN Itti W 110' i JIM FIN. FLOOR INTERIOR TYPICAL COLUMN I SOLAT1 ON JOINT SCALE 3/4" (12. SCALE 3/4" l'-0" 0 a a a I a a a CONTROL JOINT paw 000• 0110. an•••• 20•11• NN ITYP I CAL. EXTERIOR t Y FOUNPATI ON Pcitirkt42S 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER AND MIN. 4" GRANULAR FILL. 2" RIGID PERIMETER INSULATION Its EXPANSION JOINT MATERIAL 11/ POURED ELASTOMERIC POLYMER SEALANT TOP 4 CONC. SIDEWALK 11/ 6 X 6 1WIF (W1.4 X Wf.4) OVER MIN. 4" GRANULAR FU-. SLOPE Iv PER FOOT SEE CIVIL EN6. Dt165. STEEL COLUMN CONC. FOOTING, SEE FOUNDATION PLAN FIN. FLOOR PIN. PLAN '43 Ir a k SCALE 3/4" SCALE 3/4" 1 0 60tikiti LEVFLLIN6• I BEAP.ING PLATES a A SCALE 3/4" 11. PLAN 2 X 1 ANCtlIOR BOLTS (A36) 1.-r ht 5ECTION TI AL ANCHOR 9E171 N6 P!TA T R1610 PERIMETER INSULATION I. EXPANSION JOINT MATERIAL IN/ POURED ELASTOMERIG POLYMER SEALANT TOP SEE CIVIL ENG. VASS. FOR CURBS AND SIDEWALK OUTSIDE PACE OF STEEL COLUMN ANCHOR BOLT TYP I CAL EXTERIOR COLUMN PILASTER VETA I Ls• 4" CONC. SLAB OVER 6 MIL VAPOR BARMIER AND MIN. 4" GRANULAR FILL I 4" CONC. SIDEWALK PI/ 6 X 6 WIAIF (H1.4 X WI.4) OVER MIN. 4' GRANULAR FILL. SLOPE 46 PER FOOT. DOWEL TO BLOCK AT 2 0.C. REBAR AT 2LON O.G. &ROUT CORES AT REBARS SOLID CONC. FOOTING, SEE FOUNDATION TYP I CAL STOREFRONT ENTRY FOUNDATION 1/2• PREFORMED EXPANSION JOINT MATERIAL CONCRETE OR GROUT 2" RIGID PERIMETER INSULAtION FILL A/ CONCRETE MIN. PSt 4 *5 REBARS'DOWELED TO FOOTING 1 5 se TIES CONCRETE FOOTINS, SEE FOUNDATION PLAN FOR DETAILS CONSTRUCTION JOINT Zo FIN. FLOOR tONCRETE FLOOR SLAf3 a SCALE 5/4" *NT"! CAL SLAB ON GRADE JO INT SCALE I 1 'Writ CAL HALL FOUNDATION AT DOORS SCALE 3/4' II-0" (L. 4" C.ONC. SLAY3 OVER b MIL VAPOR BARRIER AND MIN. 4" GRANULAR FILL 2' mem, PERIMETER INSULATION Pi" EXPANSION JOINT MATERIAL II/ POURED ELASTOMERIC POLYMER SEALANT TOP SLOPE DR CONTROL. JOINT 4' ce*lc;. 51v94A1J(p4/ 6x6HHF (111:4 X 111.4) OVER MIN. 4" 6RANULAR FILL. SLOPE 4' PER FOOT. DOWEL TO BLOCK AT 2'-0" O.G. SEE CIVIL EKG. DWISS. FOR *4 REBAR AT 2'-0" O.G. GROUT CORES AT REBARS SOLID CONC. FOOTING, SEE FOUNDATION PLAN a, a 0 a aTYP I CAL INTER' OR COLUMN oesrAii. •4 4. STEEL COLUMN SAWED OR PREMOLDED JOINT JOINT SEALANT FIN. FLOOR JOINT FILLER NOT TO BOND 11/ SEALANT PIN. FLOOR '1? PREFORMED EXPANSION JOINT MATERIAL EDGE OF SLAB 4 CONCRE'T'E OR GROUT FIN. FLOOR' INTERIOR COLUt-1N FOOTIN5, SEE FOUNDATION PLAN 0•4" ANCHOR BOLT CONCRETE COVER IN FOOTINGS SHALL BE 3". ALL OTHER PARTS SHALL HAVE 2" COVER, UNLES OTHERWISE NOTED. GENERAL NOTES:. CONCReTe REINFORCED CONCRETE HAS BEEN tesieNED 1t4 ACCORDANCE WITH THE LATEST EDITION OF me IP 411„6„ 4RIP CONGRETEEgdsti CONCRETE INSTITUTE, REINFOING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE ACI STANDARDS, FOR BUILDINGS (ACI 301), DETAILS AND DETAILING OF CONCRETE REINFORCEMENT...Oat 315), AND THE MANUAL OF ENGIWER114/9 AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES (ACI 3I5R) BY THE AMERICAN CONCRETE INSTUTUTE, THE LATEST ErnoNE OF CONCRETE REINFORCING STEEL INSTITUTE'S ,REittORCING BAR 1?ETAILING ft.Acime REINFORCING BARS MAY ALSO BE USED. SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 302.IR. ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH THE LATEST EDMON OF COLD ingnjeg r (ACI) f3Y THE AMERIGAN CONCRETE INSTITUTE. AN ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE IF THE OUTSIDE TEMPERATURE 15 EXPECTED TO FALL BELOW 40 DEEREES FOR 24 HOURS AFTER THE POUR. THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO THE POLON& c,ONC,RETE AND COVERED UNDER THE SAME PROTECTION. SPECIAL CURING BOXES ARE NOT PERMITTED FOR THESE TEST CYLINDERS. MINIMUM CONCRETE Commessive STRENGTH OW AT 26 DAYS: FOOTINGS 3000 PSI SLAMS ON isRADE 3000 PSI CURBS, SIDEWALKS, SLABS EXPOSED TO DE-10ERS 4000 P51 (b% 1% ENTRAINED AIR BY VOLUME) CoONCIRETE RE NPORGEMENT: DEFORMED BARS NEW BILLET STEEL COMPLYING WITH ASTM A6I5-65 AND HAVING A MINIMUM YEILD STRENGTH OF 60,000 P51. WELDED HIRE FABRIC SMOOTH WIRE FABRIC COMPLYING HIM ASTM AI65. UNLESS OTHERWISE SHOWN OR NOTED, SPLICING OFt REINFORCING BARS SHALL CONFOR1-1 TO THE "REQUIREMENTS OF THE MOST CURRENT ACI BUILDING CODE. FOUNDATIONS: ALL EXTERIOR FOOTINGS TO Se 5 MINIMUM BELOW FINISH &RADE AND ON UNDISTURBED SOIL. ALL FOUNDATION EXCAVATIONS SHALL BE PERFORMED 1N ACCORDANCE WITH THE GEOTECHNICAL REPORT. THE EXCAVATION FOR EACH FOUNDATION SHALL BE INSPECTED BY A QUALIFIED eeorecHNIGAL --ENGINEER TO INSURE THAT THE DESIGN SOIL PRESSURES MAY BE OBTAINED. DESk5N NET SOIL PRESSURE: SPREAD FOOTINGS: 2000 PSF HALL FOOTINGS: 2000 PSF MASONRY ENGNEERED CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE 1121.211±1‘aaigrailigillaC5 FOR r.ONGRETE MASONRY STRUCTURES (ACI 531), BY THE AMERICAN CONCRETE INSTITUTE. CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO ALL REQUIREMENTS OF THE MOST aRRENT EDITION OF Er.ir.c MASONRY CONSTRUCTION (ACI 531.1) PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE. DESIGN MASONRY COMPRESSIVE STRENGTH (f•rn) SHALL BE 1350 PSI. MASONRY FZEINFORCEMENT: BOND BEAMS AND VERTICAL REINFORCEMENT IN BLOCK CORES: NEW BILLET STEEL COMPLYING 111TH ASTM A615-55 AND HAVING A MINIMUM YEILD STRENGTH OF 60,000 PSI. UNLESS OTHERWISE NOTED, MASONRY CORES (14HEfE SPECIFIED ON DRAWINGS) AND BOND BEAMS SHALL BE FILLED WITH CONCRETE MEETING THE FOLLOWING REQUIREMENTS: 2500 PSI 215-rwr COMPRESSIVE STRENSTH; 3/4" MAXIMUM AGGREGATE SIZE; AND 1 MAXIMUM SLUMP, PROVIDE BEARING PLATE WITH TWO I/2" X 1 HOOKED ANCHOR BOLTS AT BEAMS SEAM% ON MASONRY. SEE FRAMING PLAN FOR PLATE sizes. SPACE BOLTS AT BEAM GAGE. BEARINGS FOR I3EAMS, LINTELS, JOISTS, ETC. SHALL Be SOLID MASONRY UNITS OR HOLLOW MASONRY* UNITS WITH CORES FILLED SOLID WITH CONCRETE. Tam FOUNDATION DETAILS