R esidential P ool P ermit Application for: 749 Ironwood Drive Carmel, Indiana 46033 L ocated in the N orthern Acressubdivision P arcel N umber: 16-10-20-03-06-005.000 1. P hysical Description
of the P ool: a. T he pool perimeteris 40 feet by 20 feet with 2 foot radius corners. T he pool depth goes from 3 feet, 4 inches (40 inches) in the shallow end to a maximum depth of
8 feet (96 inches) in the deep end. T he shallow end measures 20 feet by 14 feet. T he incline from the shallow end to the deep end measures 20 feet by 14 feet. T he deep end of the
pool measures 8 feet by 12 feet. T he waterline is 6 inches below the finished surface of the deck or 3 feet, 1 inch (37 inches) in the shallow end and 7 feet, 9 inches (93 inches) in
the deep end. T he stairsare located in a cornerin the shallow end of the pool. Each step tread measures 1 foot, 2 inches (14 inches) and the step risers measure accordingly: i. T he
firstriserfrom inside the pool: 11 inches ii. T he second riserfrom inside the pool: 10.5 inches iii. T he third riserfrom inside the pool: 10.5 inches iv. T he forth and lastriserfrom
inside the pool: 8 inches T he steps extend 4 feet, 1 inch (49 inches) in each direction from the 2 foot radius corner. At this time, the following items will not be installed: i. L
adders ii. L edges iii. U nderwaterseat benches iv. Diving board v. S lide b. T he pool wallsand stepsare constructed of 14 gauge galvanized steel. T he wallsare supported by 14 gauge
“A” bracesset in aconcrete footer. T he concrete is the covered by #53 limestone. A bonded concrete deck will be poured over the #53 limestone fora finished surface. T he interior of
the pool will be lined by a 20ml vinylliner. T he liner will cover the entire pool bottom, wallsand steps. T he liner will be held in place by a cantilevercoping made ofsteel. T he cantileveris
held in place by 2 inch sheet metal screwsfastened to the galvanized steel walls. 2. Dimensions Design: S ee Attachments 1 and 2 for the dimensional design of the pooland steps 3. Designation
of P ool T ype: At this time, no diving equipment isscheduled to be installed 4. P ool Egress: S teps described as “wedding cake” stepsare located in the shallow end of the pool at one
of the two, 2 foot radius corners. T he steps will be covered by a non-slip surface built into
the vinylliner. T he decking adjacent to the steps will be textured concrete to reduce the chance ofslippage. T he following other methods of egress are not scheduled to be installed
at this time: a. Handrails b. U nderwaterseats and/orledges c. L adders 5. Electrical R equirements: S ee Attachment 3 forlocation of electrical outlets and associated photos w ithin
20 feet of the inside of the pool walls. At this time, a pool heateris not scheduled to be installed. 6. W aste W ater Disposal: T he backwash water will be disposed into asanitary sewer
through an approved air gap disposalsystem. S ee Attachment 4 for the location of the sanitary sewer, associated plumbing and associated photos. T he work will be completed by L .E.
Isley and S ons P lumbers. 7. S afety Features: T he entire backyard issurrounded by a wrought iron fence measuring 5 feet (60 inches) in height in combination with a wooden fence measuring
6 feet (72 inches). Access to the back yard islimited to aself closing, selflatching gate located located on the north side of the property m easuring 6 feet (72 inches) that is 4 feet
6 inches (54 inches wide). S ee Attachment 5 for the location of the self closing and selflatching gate and associated photos.
R esidential P ool P ermit Application for: 749 Ironwood Drive Carmel, Indiana 46033 L ocated in the N orthern Acressubdivision P arcel N umber: 16-10-20-03-06-005.000 FurtherInformation:
1. U nderwater L ight Fixture: An underwaterlight fixture will be installed in the deep end of the poolas portrayed in Attachment 6. It will be a 120 volt, 400 watt fixture. a. T he
light w ill have an insulated #8 copper bond wire from the light shell to the light junction box. b. T he bond wire will be insulated in the conduit from the light to the light fixture
junction box. 2. T he location of the light fixture junction box is portrayed in Attachment 7. 3. T he location of the pool circulation pump and filterare portrayed in Attachment 8.
4. T he location of the pool circulation pump disconnect switch is portrayed in Attachment 9. 5. T he locations ofall 120 volt electricalreceptaclesare portrayed in Attachment 3. All
receptaclesare located more than 10 feet from the pools edge and they are on a GFCI protected circuit. circuit. 6. N o additionallighting fixtures, high orlow voltage, are located within
10 feet of the pool. 7. A pool coveris not being installed and therefore a pool coverswitch in not applicable. 8. T he locations of electricalswitchesare portrayed in Attachment 9. T
hese switchesare for the pool circulation pump and poollight. 9. T he site drainage is portrayed in Attachment 10. 10. T he side view of the pool, showing depthsand change in depth and
length are portrayed in Attachments 1 and 2. 11. A diving board is not going to be installed 12. Handrails will not be installed 13. T hisis not applicable because an in-ground poolis
being installed
R esidential P ool P ermit Application for: 749 Ironwood Drive Carmel, Indiana 46033 L ocated in the N orthern Acressubdivision P arcel N umber: 16-10-20-03-06-005.000 Additionally:
1. S ite/P lot P lan: a. T he location of the pool, including setbackofpoolfrom side and rear yard and any easementsfrom the edge of the coping are portrayed in Attachment 11. At this
time, the dimensions of the deck have not been decided. b. T he location of the principle residence is portrayed in Attachment 12. c. T here is not a detached garage, driveway ofaccessory
buildingsin the area of the pool d. T he locations of the easementsare portrayed in Attachment 13. e. A septictank, leach field nor wellislocated in the area of the pool. f. T he location
of the utilitiesservice box, buried linesand connection to the house are portrayed in Attachment 14. g. T he site drainage is portrayed in Attachment 10. T hisis how the area will drain
after the poolis constructed. h. T he location of the poolfilter and circulation pump is portrayed in Attachment 8. A heater, automatic pool cover, automaticfill device or backflow preventerare
not being installed. i. T he dimensions of the deck have not been decided. j. T here are not any retaining walls or otherconstruction being installed. 2. R ight-O f-W ay P ermit: A right-of-way
permit is currently on file for 749 Ironwood Dr. under the permit holder of T odd L awson 3. T he Color P attern or Finish of the P oolInterior: T he colorand pattern of the poollinercan
be viewed in Attachment 15. 4. O rdinances & R egulations: a. A septic system is not present in the vicinity of the pool b. T he location of the pooland associated concrete coping in
relation to the easements can be reviewed on Attachment 11.
ATTACHMENT 3
Photos of outlet A: 1 of 2
Photos of outlet A: 2 of 2
Photos of outlet B: 1 of 2
Photos of outlet A: 1 of 2
ATTACHMENT 4
Photos of Wastewater disposal: 1 of 5 Outside view
Photos of Wastewater disposal: 2 of 5 Outside view -close-up
Photos of Wastewater disposal: 3 of 5 Inside view as it comes in from outside
Photos of Wastewater disposal: 4 of 5 Inside view as pipe angles towards the floor
Photos of Wastewater disposal: 5 of 5 Inside view as pipe runs along sanitary sewer.
ATTACHMENT 5
Photos of Safety Features disposal: 1 of 6 Safety Feature – Fence: North west side of the property. Primary entrance – self closing, self latching gate with the ability to lock.
Photos of Safety Features disposal: 2 of 6 Safety Feature – Fence: South west side of the property.
Photos of Safety Features disposal: 3 of 6 Safety Feature – Fence: South side of the property.
Photos of Safety Features disposal: 4 of 6 Safety Feature – Fence: North side of the property.
Photos of Safety Features disposal: 5 of 6 Safety Feature – Fence: North side of the property.
Photos of Safety Features disposal: 6 of 6 Safety Feature – Fence: East side of the property.
ATTACHMENT 6
ATTACHMENT 7
Light Fixture Switch Photo: 1 of 2
Light Fixture Switch Photo: 2 of 2
ATTACHMENT 8
ATTACHMENT 9
Circulation Pump Switch Photo: 1 of 2
Circulation Pump Switch Photo: 2 of 2
ATTACHMENT 10
ATTACHMENT 11
ATTACHMENT 12
ATTACHMENT 13
ATTACHMENT 14
ATTACHMENT 15