HomeMy WebLinkAbout19 Code-Master Second Floor Plan - A0.3EXISTING THREE STORY CLASSROOM CONSTRUCTION EXISTING 4 HOUR WALL CONSTRUCTION BETWEEN 3 STORY AND 1 AND 2 STORY CONSTRUCTION 3i STAIR ONE VARIANCE 'B' THREE STORY ACADEMIC ADDITION OCCUPANCY El CONSTRUCTION TYPE: I I ONE HOUR VARIANCE IS FOR CONSTRUCTION TYPE II ONE HOUR IN LIEU OF TYPE II FR 41' w_I NEW ADDITION EXISTING STAIR TWO r awesamo- NEW ROOF EXISTING ROOF l 4. EXISTING TWO STORY CLASSROOM CONSTRUCTION STAIR THREE ONE HOUR EXIT STAIR EXITS INTO FIRST FLOOR UNPROTECTED CORRIDOR EXISTING ROOF 248' -6" IN COURTYARD EXISTING ROOF EXISTING LNG as NEW 4DD NEW ROOF COURTYARD a a a a a a a a a IW NEW ROOF EXISTING ROOF EXISTING ROOF a EXISTING ROOF EXISTING ROOF EXISTING .Ns NEW ADDITION NEW ADDITION EXISTING BUILDING CODE SUMMARY OCCUPANCY CONSTRUCTION TYPE EXISTING BUILDING AREA LOWER LEVEL FLOOR FIRST FLOOR SECOND FLOOR THIRD FLOOR MECHANICAL PENTHOUSES SUB LEVEL MECHANICAL PLANT SUB TOTAL NEW ADDITIONS ACADEMIC ADDITION LOWER LEVEL AUX. GYM S T OR_ MECHANICAL FANROOM PERFORMING ARTS ADDITION PERFORMING ARTS ADDITION LOWER LEVEL STORAGE MECHANICAL FANROOM SUB TOTAL TOTAL GROSS S.F. TOTAL PERIMETER 5,344 FEET 1. THE ENTIRE BUILDING IS FULLY SPR'NKLERED 2. ALL INFORMATION IS BASED UPON THE 1998 INDIANA BUILDING CODE 3. ALL INTERIOR FINISHES SHALL BE BE IN ACCORDANCE WI TH CHAPTER 8 OF THE UNIFORM BUILDING CODE 4. AREA OF ANY 1 OR 2 STORY BUILDING OF GROUPS E OCCUPANCY SHALL NOT BE LIMITED IF THE BUILDING IS EQUIPPED WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM AND SURROUNDED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60' IN WIDTH (SECTION 505.2 AND 505.3 AMENDMENT OF 1998 INDIANA BUILDING CODE) LEGEND IN 1 HOUR FIRE RESISTIVE OCCUPANCY SEPARATION WITH 60 MINUTE FIRE RESISTIVE OPENINGS I i I I I I i 2 HOUR `IRE RESIST.VE OCCUPANCY SE-='ARATION WITH 90 MINUTE FIRE RESISTIVE OPENINGS (SEPARATION OF ELEVATOR SHAFT, AND MACHINE ROOM) E1 A3 II (MUSIC ADDITION AND NEW CAFETERIA) !I 1 HOUR (ACADEMIC ADDITION) 4 HOUR FIRE RESISTIVE OCCUPANCY SEPARATION WI 3 HOUR FIRE RESISTIVE OPENINGS ONE HOUR PROTECTED EXIT ENCLOSURE FIREPROOFING GENERAL NOTES 103,219 S.F. 451,086 S.F. 169,970 S.F. 39,260 S.F. 7, 542 S.F. 5,570 S.F. 776,647 S.F. 152,656 S.F. 820 S.F. 5,600 S.F. 10,740 S.F. 2,788 S.F. 1,340 S.F. 173,944 S.F. 950,591 S.F. 1. PROVIDE ONE HOUR FIRE PROOFING ON ALL PRIMARY AND SECONDARY STEEL MEMBERS IN CROSS HATCHED AREA, WHICH INCLUDE FLOOR AND ROOF BEAMS, AND ROOF DECKS. 2. NO SPRAYED ON FIRE PROOFING IS REQUIRED ON THE ELEVATED SLABS AND CONCEALED COLUMNS. THE COLUMNS ARE PROTECTED WITH ONE HOUR CONSTRUCTION AND MEET UL DESIGN NUMBERS U415 OR U469 THE ELEVATED SLABS MEET UL DESIGN NUMBERS 0902, D914, D916, D918, AND D919 FOR RESTRAINED ONE HOUR RATING. PROVIDE ONE HOUR FIRE PROOFING AT ANY EXPOSED PORTION OF COLUMN AND AT CONNECTION OF BEAMS TO COLUMNS. REFERENCE PLAN DETAILS AND WALL TYPES FOR ADDITIONAL INFORMATION. 3. REFERENCE THE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR FIRESTOPPING DUCT, PIPE AND CONDUIT PENETRATIONS OF RATED WALLS AND FLOORS. CODE /MASTER SECOND FLOOR PLAN J w 2 I- U Z co W U 2 �zo Q J W (n W cr cc U- 0 J W U U 0 O O O N w O Z co. O CHS FRESHMAN CENTER 201 105.00 SECOND FLOOR KEYPLAN