Loading...
HomeMy WebLinkAbout20 Code-Master Third Floor Plan - A0.4EXISTING THREE STORY CLASSROOM CONSTRUCTION REQUIRED ON STEEL MEMBERS IN STAIR ABOVE THE ADJACENT ROOF LEVELS NO FIRE PROOFING IS REQUIRE IN THE MECHANICAL PENTH FLOOR IS ONE HOUR R FROM LEVEL BELOW EXTEND 2 ROOF DEC NOT REo,. MECHA fj SEPARATION ELEVATOR SHAFT TO DECK. ABOVE ELEVATOR SHAFT DOES RE FIRE PROOFING USE CODE PLAN SCALE: 1' 50'-0" STAIR ONE VARIANCE 'B' NEW ADDITION EXISTING 248'— THREE STORY ACADEMIC ADDITION OCCUPANCY El CONSTRUCTION TYPE: II ONE HOUR VARIANCE IS FOR CONSTRUCTION TYPE II ONE HOUR IN LIEU OF TYPE II FR W EXISTING ROOF STAIR THREE ONE HOUR EXIT STAIR EXITS INTO FIRST FLOOR UNPROTECTED CORRIDOR a s EXISTING ROOF a EXISTING ROOF 11 EXISTING ROOF wa SING r NEW a a a COURTYARD a a NEW ROOF a COURTYARD W a a EXISTING ROOF EXISTING ROOF EXISTING ROOF i i i W MI a EXISTING ROOF WI a EXISTING NEW ADDITION NEW ADDITION EXISTING BUILDING CODE SUMMARY OCCUPANCY CONSTRUCTION TYPE EXISTING BUILDING AREA LOWER LEVEL FLOOR FIRST FLOOR SECOND FLOOR THIRD FLOOR MECHANICAL PENTHOUSES SUB LEVEL MECHANICAL PLANT SUB TOTAL NEW ADDITIONS ACADEMIC ADDITION LOWER LEVEL AUX. GYM STOR. MECHANICAL FANROOM PERFORMING ARTS ADDITION PERFORMING ARTS ADDITION LOWER LEVEL STORAGE MECHANICAL FANROOM SUB TOTAL LEGEND CODE /MASTER THIRD FLOOR PLAN El, A3 Ii N (MUSIC ADDITION AND NEW CAFETERIA) II I HOUR (ACADEMIC ADDITION) 103,219 S.F. 451,086 S.F. 169,970 S.F. 39,260 S.F. 7,542 S.F. 5.570 S.F. 776,647 S.F. 152,656 S.F. 820 S.F. 5,600 S.F. 10,740 S.F. 2,788 S.F. 1,340 S.F. 173,944 S.F. TOTAL GROSS S.F. 950,591 S.F. TOTAL PERIMETER 5,344 FEET 1. THE ENTIRE BUILDING IS FULLY SPRINKLERED 2. ALL INFORMATION IS BASED UPON THE 1998 INDIANA BUILDING CODE 3. ALL INTERIOR FINISHES SHALL BE BE IN ACCORDANCE WITH CHAPTER 8 OF THE UNIFORM BUILDING CODE 4. AREA OF ANY 1 OR 2 STORY BUILDING OF GROUPS E OCCUPANCY SHALL NOT BE LIMITED IF THE BUILDING IS EQUIPPED WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM AND SURROUNDED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60' IN WIDTH (SECTION 505.2 AND 505.3 AMENDMENT OF 1998 INDIANA BUILDING CODE) 1 HOUR FIRE RESISTIVE OCCUPANCY SEPARATION WITH 60 MINUTE FIRE RESISTIVE OPENINGS l 1 i 1 1 l 1 i 1 1 2 HOUR FIRE RESISTIVE OCCUPANCY SEPARATION WITH 90 MINUTE FIRE RESISTIVE OPENINGS (SEPARATION OF ELEVATOR SHAFT AND MACHINE ROOM) SCALE: 4 HOUR FIRE RESISTIVE OCCUPANCY SEPARATION WITH 3 HOUR FIRE RESISTIVE OPENINGS ONE HOUR PROTECTED EXIT ENCLOSURE FIREPROOFING GENERAL NOTES 1. PROVIDE ONE HOUR FIRE PROOFING ON ALL PRIMARY AND SECONDARY STEEL MEMBERS IN CROSS HATCHED AREA, WHICH INCLUDE FLOOR AND ROOF BEAMS, AND ROOF DECKS. 2. NO SPRAYED ON FIRE PROOFING IS REQUIRED ON THE ELEVATED SLABS AND CONCEALED COLUMNS. THE COLUMNS ARE PROTECTED WITH ONE HOUR CONSTRUCTION AND MEET UL DESIGN NUMBERS U415 OR U469 THE ELEVATED SLABS MEET UL DESIGN NUMBERS D902, D914, D916, D918, AND D919 FOR RESTRAINED ONE HOUR RATING. PROVIDE ONE HOUR FIRE PROOFING AT ANY EXPOSED PORTION OF COLUMN AND AT CONNECTION OF BEAMS TO COLUMNS. REFERENCE PLAN DETAILS AND WALL TYPES FOR ADDITIONAL INFORMATION. 3. REFERENCE THE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR FIRESTOPPING DUCT, PIPE AND CONDUIT PENETRATIONS OF RATED WALLS AND FLOORS. 50'—C" THIRD FLOOR KEYPLAN U >*1 uo--4 E.N1 v•-.4 O t cti).50 44 w as w Lri a cN O jj Z 2 o CHS FRESHMAN CENTER 201 1 05.00