Loading...
HomeMy WebLinkAbout13 Site Utility Demolition Plan West- SU1.2Invert 835.1 12"CMP Invert 834.9 Invert 830. Invert 833. Invert 834. 8 40 1/1 4 40.1. 1 1111111111 1y e i„ i r nve 8 9. 100 1 2" RCP nvert 83 I IN .21 GM 5.86 1 1" 4. 1 6 1 1 I AM 11 OR 11117 i) P"'" F P' ‘AZ eh "Willy, imp M O P sa Fon 1 —.Drill .--a oir MI htll. A 111 del mum 4.11".. If Ininowiliosa% I,K 4 6. cLommbillI;;11111 lou_ PIMIIIELT=2" 7-- F mil dinkiimmuk „....,,,.,„at=-,..,,„...... or IIIIITIRAWAr WW1 OW alij 0 2 s e 0 \r4w1 I ime „ilrom woo trAeZ.44 1 11111 18"RCP 30” RCP 1 2" RC p sTm 18" RCP 1 2" RCP 1 0" VC P STM MIN GTE SAI\1 G T 18 RC 1 0" VCA 1 8" P 1 Thn: 12" RCP STR. 208 MII111111111111111111111111 C III I IIIIIII I 111111‘. 1 12" RCP 111111P1111111 St PVC r r 12" PVC 2" CPVC SITE UTILITY PLAN WEST SCALE: 1 30' /0" PVC CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO 6* AT INV. EL XXX.XX (FROM ACID NEUTR. BASIN) 70' OF 6" PVC SANITARY AT X.X% SLOPE. CONNECT NEW Er TO MANHOLE AT INV. EL XXX.XX. CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO X* AT INV. EL XXX.XX (FROM COURTYARD DRAINS) 30' OF X* PVC STORM AT X.X% SLOPE. CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO 12* AT INV. EL 836.87 80' OF 12* PVC SANITARY AT X.X% SLOPE. 40 CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO 6* AT INV. EL 834.50 50 OF 6* PVC SANITARY AT X.X% SLOPE. CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO 10* STORM AT INV. EL 84927 OF 12" PVC STORM AT X.X% SLOPE. 1,000- GALLON GREASE INTERCEPTOR SEE DETAIL 10/SU1.5. 8' OF 8* PVC SANITARY AT X.X% SLOPE. CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO X'' AT INV. EL 845213. 8' OF 8- PVC STORM AT X.X% SLOPE. CLEANOUT- SEE DETAIL 7/SU1.5. CONNECT TO 12* AT INV. EL 850.18. 27' OF 12" PVC STORM AT X.X% SLOPE. PLAN NOTES GENERAL SITE UTILITY PLAN NOTES SEE SHEET PSU2.1 FOR SITE WATER AND GAS LINES. SITE SEWER CONTRACTOR SHALL COORDINATE WORK WITH THE SITE PLUMBING/ARE PROTECTION CONTRACTORS. THE PLANS SHOW THE LOCATION OF UTIUTIES LOCATED WITHIN THE LIMITS OF THE CONTRACT ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THE INFORMATION IS NOT GUARANTEED. IT IS THE CONTRACTOR'S RESPONSIBIUTY TO NOTIFY AND COORDINATE CONSTRUCTION WITH ALL RESPECTIVE UTIUTIES. EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. PVC PIPE TO BE USED ONLY AT LOCATIONS SHOWN AND SHALL NOT BE SUBSTITUTED FOR RCP. SEE PLUMBING DRAWINGS FOR CONTINUATION OF UTIUTIES INTO BUILDING. SEE E2.1 FOR SITE ELECTRICAL PLAN. 8. CONSTRUCTION OF ALL SEWER UNES AND STRUCTURES SHALL BE IN ACCORDANCE W111-1 LOCAL AND STATE CODES, RULES AND REGULATIONS. 9 WHERE WATER LINES AND SEWERS CROSS AND THE WATER LINE CANNOT BE PLACED ABOVE OR BELOW THE SEWER WITH A MINIMUM OF 18- VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS WITHIN 10' OF THE WATER LINE. THE WATER LINES SHALL BE INSTALLED ABOVE THE SEWER WHERE EVER POSSIBLE. 10. WHERE WATER LINES AND SEWERS RUN PARALLEL AND A MINIMUM SEPARATION DISTANCE OF 10' CANNOT BE MAINTAINED, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS. 11. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL STANDARDS. 12. CONTRACTOR SHALL REPLACE ALL PAVING AND CURBS TO MATCH EXISTING AT UTIUTY CUTS. STM SAN SM -10 EX-1 STR. 206 0 1><1 El LEGEND NEW STORM SEWER NEW SANITARY SEWER WATER MAIN EXISTING STORM SEWER EXISTING SANITARY SEWER SANITARY STRUCTURE NUMBER EXISTING SANITARY MANHOLE STORM STRUCTURE NUMBER VALVE MANHOLE INLET INVERT ELEVATION CLEANOUT FIRE HYDRANT CAUTION THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. 1-800-382-5544 WITHIN INDIANA 1 FOR CITY OF CARMEL UTILITIES CONSULTING ENGINEERS Ter Horst, Lamson Fisk, Inc. 8675 Purdue Road Indianapolis, IN 46268 Phone: 317-334-1500 Fax: 317-334-1552 ME PROJECT NO. 2001 CARMEL HIGH SCHOOL 201105.00