HomeMy WebLinkAboutS111 Foundation-Slab Plan, Framing Plan, & Detailso �-z z oo 0 UN= �w QQ 01-ys� o o N� Nw2= N O Ng% P Z,33Mwommow�oo ;;cDD -J 00 O0, --.03 (X w F- w O (42W`'00.. r cY Q M o =N Zip( 0,'Z„ ZOC'-. U z ?N a ou p J z _,,W =Q WQ K �O�QEzO =Or=-cOOx r u- w�dzd' n.0�0¢wsnUO t�awo ime if I I CAI 6 i 8R01 I D u D p u s l o a D u D p u l l Michael E. Balay, AIA 6801 Lake Plaza Drive, Suite C -305 Indianapolis, Indiana 46220 Tel: (317) 845 -9402 Fax: (317) 845 -9428 mike@balayarehitects.com I DT O S B U u I tAJ a a D M I I l B A L A Y ARCHITECTS PROJECT NO.: 0235 r CHECKED BY: MEB DESCRIPTION J DATE: 07/10/02 SCALE: 1 =1 ISSUE DATE: 7/12/02 DRAWN BY: ID '11N1 31Va >12IVW viva 'elm ICC viva '11d 2002 BALAY ARCHITECTS, INC. FOUNDATION /SLAB PLAN, FRAMING PLAN, AND DETAILS sill N I 1 4■■■■■Mii7:: 8:I2 5L. 8:12 ONIM FRAMING PLAN SCALE: 1/4" 1' -0" 8:12 5L. MI* 0111101MIIIMINOIMI. ONO 8:12 SL. RIDGE LINE LINE OF WALL BELOW 5/8" SHEATHING OVER WOOD TRUSSES AT 2' -O" O.G. TYP. CONTROL JOINT C.J. SEE NOTES FOR SLAB REIWORCEMENT TYP. CONSTRUCTION JOINT) FLOOR JOINTS SHALL BE SPACED A5 SHOWN ON PLAN AND WHERE POSSIBLE FLOOR JOINTS SHALL BE LOCATED ALONG COLUMN LINES. CONSTRUCTION JOINT LOCATIONS MUST BE APPROVED BY THE ENGINEER. SECTION SCALE: 1 1 /2" 1' -0" I/2 DIA. x 24 AT 24' D.G. DOI't. W 6' INTO EXI5TIN6). EXISTING CONCRETE SLAB. 0 I m SLAB THRU OPENING SEE FLOOR PLAN FOR EXACT LOCATIONS GENERAL CONSTRUCTION NOTES I. DO NOT SCALE THE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. ALL DIMENSIONS SHOULD BE FIELD VERIFIED BY THE CONTRACTOR. 2. ALL PLAN DIMENSIONS ARE FROM COLUMN CENTERLINE, FACE OF STUD, OR FACE OF CMU, UNLESS NOTED OTHERWISE. 2. ALL FOUNDATION/BLAB PLAN DIMENSIONS ARE FROM OUTSIDE FACE OF CONCRETE FOUNDATION, UNLESS NOTED OTHERWISE. 3. ARCHITECT MUST BE IMMEDIATELY NOTIFIED OF ANY DISCREPANCIES IN DIMENSIONS, CODE REQUIREMENTS (BOTH LOCAL AND STATE), AND /OR OTHER CONDITIONS INDICATED BY THESE DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK. IF EXISTING JOB SITE CONDITIONS ARE DIFFERENT THAN THOSE ILLUSTRATED IN THE CONTRACT DOCUMENTS, IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING. 18 —on TOP OF SLAB ELEV. 100 -0` TO MATCH EXISTING STRUCTURE TO THE WEST FOUNDATION /SLAB PLAN SCALE: 1 /4" 4. THE CONTRACTOR SHALL VERIFY ALL MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCES PRIOR TO PROCEEDING WITH THE WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 5. TRUSS MANUFACTURER TO DESIGN ENTIRE ROOF SYSTEM PER STATE AND LOCAL CODES. SEE ARCHITECTURAL AND MEP DRAWINGS FOR ADDITIONAL INFORMATION REGARDING STORAGE, MECHANICAL UNITS, ETC. TO BE DESIGNED INTO THE TRUSSES. 6. BOTTOM OF FOOTING ELEVATION SEE BUILDING SECTION. FOOTING SEE BUILDING SECTION FOUNDATION WALL SEE BUILDING SECTION 4" CONCRETE SLAB -ON -GRADE WITH 6x6- 1/42.9x142.9 W.W.R. ON 4" COMPACTED BASE CONSTRUCT' ON /CONTROL JOINTS SEE DETAIL