SYMBOL
LAY
MANUFACTURER
CATALOG NO.
CEE17-
120V EMERGENCY LITE W /LEAD
BATTERY AND 2 MTD HERD.
EMEiZGLITE
WSRXI2R -2EP9
I
I'X4' FLOURESGENT LIGHT, 3 LAMPS.
DAYBRITE
XXXXX -xxx
(8)
CAI
p
01 moo
c) ..41.•
No.
k 880149
v. il STATE OF
kt/s/ D
**Zi HI
ing flo
tastiAL., Ai/L.4w
L"
I
Dup!puls!ioaDup!puil
Michael E. Balay, AIA
6801 Lake Plaza Drive,
Suite C-305
Indianapolis, Indiana 46220
Tel: (317) 845-9402
Fax: (317) 845-9428
mike@balayarchitects.com
1 D 1. 080 U U J 0 1. D M I 1 I
B Y
ARCHITECTS
PROJECT NO.: 0235
r CHECKED BY: MEB
DESCRIPTION
DATE: 07/10/02 SCALE: 1=1
PLOTTED BY: Mike
ISSUE DATE: 7/12/02
DRAWN BY: ID
p.1.1N1
3.1.V0
vival
eMa
WI
IC 0
17.7.721
'lid
2002 BALAY ARCHITECTS, INC.
LIGHTING, POWER,
MECHANICAL, AND
PLUMBING PLANS
A141
LIGHTING FIXTURE SCHEDULE
SYMBOL
DESCRIPTION
MANUFACTURER
CATALOG NO.
CEE17-
120V EMERGENCY LITE W /LEAD
BATTERY AND 2 MTD HERD.
EMEiZGLITE
WSRXI2R -2EP9
I
I'X4' FLOURESGENT LIGHT, 3 LAMPS.
DAYBRITE
XXXXX -xxx
(8)
WALL MTD. EXIT LIGHT
p
4" WASTE FOR
FUTURE WATER
CLOSET CAP
AS REQUIRED
VENT THRU
ROOF
TIE INTO
EXISTING
UTILITIES AS
REQUIRED
CAP SUPPLY AS
REQUIRED
2" WASTE FOR
FUTURE
LAVATORY
CAP AS
REQUIRED
1" m TER
k
—1
FLOOR DRAIN
FUTURE i
UNI -SEX 1'
TOILET I
02 I 1
1 II,
I Ili
L_
N
ARCH! VAL 8 CONSERVATION CENTER
r #101 j
PLUMBING FLOOR PLAN
SCALE: 1/4" 1' -0"
k f'
GENERAL PLUMBING NOTES
1. ALL WORK SHALL CONFORM TO STATE AND LOCAL PLUMBING AND BACKFLOW PREVENTION
CODES, AND THE REQUIREMENTS OF THE LOCAL WATER UTILITY.
2. VACUUM BREAKERS MUST BE INSTALLED ON ALL EXISTING AND PROPOSED HOSE THREAD
FITTINGS, INCLUDING BUT NOT LIMITED TO HOSE BIBBS, WALL /YARD HYDRANTS, MOP /SERVICE
SINKS.
4. ALL MATERIALS INSTALLED WITHIN PLENUM SHALL HAVE FLAME SPREAD RATING OF NOT MORE
THAN 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50 IN ACCORDANCE WITH STATE
CODES.
5. THIS CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR FOR CORE DRILLING
AS REQUIRED FOR INSTALLATION OF PIPING PENETRATING BUILDING CONSTRUCTION.
6. TYPE "K" COPPER TUBING SHALL BE USED FOR ALL DOMESTIC SUPPLY PLUMBING BELOW SLAB.
NO FITTINGS IE. COUPLINGS, TEES, OR ELBOWS SHALL BE USED BELOW OR WITHIN SLAB.
7. REFERENCE ARCHITECTURAL DRAWINGS FOR FINISHED FLOOR ELEVATIONS. COORDINATE PLUMBING
UNDERGROUND INVERTS WITH FLOOR DRAIN LOCATIONS AND EXISTING BUILDING SEWER.
PLUMBING INVERTS SHOWN ARE FOR ESTIMATION PURPOSES ONLY, AND SHOULD ALL
BE FIELD VERIFIED.
8. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, TYPICAL.
CONCRETE PAD.
AIR CONDITIONING
CONDENSING UNIT.
1
D- I
)(XXX)
I
D- I
(XXX)
UTURE
UNI -SEX
TOILET
41402
I
X" 0
ARCHIVAL, COI.4S VATION CENTER
ThOI f
X" m
X" 0
X" m
X" 0
X" 0
1. COORDINATE ALL WORK WITH OTHER TRADES AS REQUIRED.
X" m
MECHANI CAL
DUCTWORK TO BE
ROUTED THROUGH
ATTIC TRUSSES, TYP.
J
D- I
D- I
(XXX)
MECHANICAL FLOOR PLAN
SCALE: 1 /4" 1' -0"
F
GENERAL MECHANICAL NOTES
2. EQUIPMENT, PIPING, AND DUCTWORK LAYOUTS ARE SCHEMATIC IN NATURE. CONTRACTOR
MUST ADJUST TO FIELD CONDITIONS AND COORDINATE WITH OTHER TRADES DURING
CONSTRUCTION BY ADDING OFFSETS AND ELBOWS WHERE REQUIRED.
3. PRIOR TO INSTALLATION, THE ENGINEER SHALL APPROVE ALL PROPOSED MODIFICATIONS
TO DUCTWORK LAYOUT AND DESIGN.
4. UNLESS INDICATED OTHERWISE, ALL ROUND DUCT SHALL BE WRAPPED WITH INSULATION
AND ALL RECTANGULAR DUCT SHALL BE LINED, PER SPECIFICATIONS.
7. COORDINATE EXACT LOCATION OF CEILING DIFFUSERS AND GRILLES WITH LIGHTS.
8. FLEXIBLE DUCT SHALL NOT BE USED FOR STRAIGHT LINE DUCT SEGMENTS EXCEEDING
6 FEET. WHEN CONNECTING DIFFUSERS OR GRILLES TO RIGID DUCTWORK, USE RIGID
METAL ELBOWS FOR CHANGES IN DIRECTION.
10. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, TYPICAL.
11. ALL SIZES SHOWN FOR DUCTWORK ARE IN INCHES, UNLESS NOTED OTHERWISE.
12. SHEETMETAL CONTRACTOR SHALL FABRICATE ALL DUCT TAKE -OFF FITTINGS AS SHOWN
CONTRACT DETAIL SHEET.
13. DUCT SIZES LISTED ARE "INSIDE FREE AREA" AND SHALL NOT BE REDUCED. INCREASE
DUCT SIZES AS REQUIRED TO ACCOUNT FOR DUCT LINER.
5. GENERAL MECHANICAL NOTES APPLY TO ALL MECHANICAL DRAWING SHEETS SPECIFICATIONS.
6. ALL MATERIALS INSTALLED WITHIN PLENUM SHALL HAVE A FLAME SPREAD RATING OF NOT
MORE THAN 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50 IN ACCORDANCE
WITH STATE CODES.
9. THIS CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, AND LABOR REQUIRED FOR
CORE DRILLING AS REQUIRED FOR INSTALLATION OF MATERIAL PENETRATING BUILDING
CONSTRUCTION.
ELECTRIC C RESI STANGE
FURNACE.
NEW ELECTRIC METER
(I REQUIRED)
NEW ELECTRIC PANEL
GENERAL NOTES
I ir s
1 19
FUTURE
SWI
FURNACE DISCONNECT
1 19
L
I F'
I F
ARCHIVAL_ CONSERVATION CENTER
-,O_! j
c):11
LIGHTING AND POWER PLAN
SCALE: 1 /4" 1' -0"
I) CONSULT W/ OWNER FOR EXACT LOCATIONS OF ELECTRIC OUTLETS TELEPHONE JACKS PRIOR TO CONSTRUCTION.
2) COORDINATE W/ MECHANICAL CONTRACTOR FOR ALL MECHANICAL EQUIPMENT LOCATIONS AND ELECTRICAL REQUIREMENTS.
3) COORDINATE W/ OWNER FOR LOCATIONS AND FIXTURES FOR ALL EXTERIOR BUILDING LIGHTING.
4) ALL REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO ARCHITECT FOR APPROVAL.
5) CONSULT W/ OWNER FOR ALL SWITCH LOCATIONS.