HomeMy WebLinkAboutAmenity Area - A-1 FoundationN 0 O GENERAL FOUNDATION NOTES: 1. FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES OR DEVIATIONS PRIOR TO START OF CONSTRUCTION. 2. REMOVE ALL TOPSOIL TO MINIMUM DEPTH OF SIX INCHES IN AREAS TO BE OCCUPIED BY PAVING, CONCRETE, BUILDING OR OTHER STRUCTURES. STORE TOPSOIL THAT 15 REQUIRED FOR FUTURE USE ON T1-115 SITE. IF APPLICABLE. REMOVE ALL EXCESS TOPSOIL AND DEBRIS FROM SITE. 3. EXCAVATE SITE AS REQUIRED TO FINISH GRADE WITH A SUITABLE ALLOWANCE FOR TOPSOIL AND OR PAVING. FILL AREAS WHERE LADE RAISE IS REQUIRED WITH EXCAVATED OR IMPORTED I,ARTH. EARTH USED OFR FILL SHALL BE FREE FROM ORGANIC MATTER AND LARGE ROCKS. PLACE FILL MATERIAL IN LAYERS NOT TO EXCEED SIX INCHES IN LOOSE DEPTH. REMOVE ALL EXCESS EXCAVATED MATERIAL FROM THE SITE. 4. DEPTH OF FOOTING SHALL BE A5 INDICATED OR TO UNDISTURBED EARTH, WHICHEVER IS GREATER BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 2` -8' BELOW FINISH GRADE. 5. ANCCI.4OR BOLTS TO BE SPACED X48' O.C. MAX. AND WITHIN 12° OF OUTSIDE CORNERS (SEE DETAILS) 6. SEE ARCHITECTURAL DRAWINGS FOR MISCELLANEOUS SECTIONS, DETAILS SIZES AND LOCATION OF SLABS, FOUNDATIONS, PIERS, FOOTINGS, REINFORCING STEEL ANCI -IOR BOLTS, FILLS AND GRADES. 1, ALL CONCRETE 15 DESIGNED AND SHALL BE PLACED IN ACCORDANCE WI714 CURRENT A.C.I. CODES. (STANDARD SPECIFICATION FOR READY MIX CONCRETE) S. ALL CONCRETE FOOTINGS AND INTERIOR SLABS SHALL BE 3,000 PSI ®28 DAYS. 9. ALL REINFORCING BARS SHALL i-IAVE A MINIMUM CONCRETE COVER OF FOOTINGS =3' SLABS 3/4' PIERS =3' WALLS 1 1/2' 0 EP. AND 3' TOP AND BOTTOM 10, REINFORCING BARS AI-IVE TO BE SPLICED IN ACCORDANCE WITH CURRENT A.C.I. CODES: A. ANCHOR BOLTS SHALL NOT BE SET WITH CUMULATIVE MEASUREMENTS B. ALL EXPOSED CONCRETE CAST CORNERS TO HAVE 3/4° CHAMFERS UNLESS OTHERWISE NOTED. 11. ALL REINFORCING STEEL 5HALL BE GRADE 60 RAIL OR BILLET STEEL IN ACCORDANCE WITH ASTM A -615 SPECIFICATIONS. 12, BEARING CAPACITY OF SOILS: ASSUMED TO BE 2,500 P5F FOR COLUMN FOOTINGS AND 2,000 PSF FOR CONTINUOUS SPREAD FOOTINGS. IF POOR SOIL CONDITIONS ARE ENCOUNTERED. PROVIDE CORRECTED PROCEDURES AS FORMULATED BY SOILS ENGINEER AND AS OUTLINED IN THE SOILS REPORT 13. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS ON DRAWINGS AND REPORT ANY DISCREPANCY TO ARCHITECT BEFORE CONSTRUCTION HAS COMMENCED. 14. FOOTINTCs5 SHALL BEAR ON COMPACTED FILL OR ACCEPTABLE VIRGIN SOIL AT A MINIMUM DEPTH BELOW THE FROST LINE. 15. GENERAL CONTRACTOR AND FOUNDATION CONTRACTOR SHALL E5E RESPONSIBLE TO PROVIDE THE NECESSARY AND REQUIRED SLEEVES IN FONDATION WALL FOR ALL UTILITIES. SLEEVE LOCATIONS ARE TO SE VERIFIED BY AND IN ACORDANCE WITH THE ELECTRICAL, MECHANICAL, AND PLUMBING CONTRACTOR RECOMMENDATIONS. !6. GENERAL CONTRACTOR 15 RESPONSIBLE FOR PATCHING ARC'UND SLEEVES TO PROVIDE A LEAK -PROOF FOUNDATION. 11. ALL ABOVE GRADE CONCRETE SLABS SHALL CONTAIN 'NYLON FIBER ADDITIVE OR APPROVED EQUIVALENT IN THE AMOUNT OF 1.5LB5 PER CU YD. PLACE IN ACCORD WITH THE MANUFACTURES INSTRUCTIONS. 18. NO CONCRETE SLUMP SHALL EXCEED 4' 19. COLD WEATHER CONCRETE SHALL 8E PLACED IN ACCORD WITH ACI 3068 20.CURE ALL HORIZONTAL SURFACES WITH LIQUID CURING COMPOUND. VERIFY COMPATIBILITY WITH SURFACE COATING TO BE UTILIZED IN REST ROOMS_ 21. ALL EXPANSION JOINTS NOTED AS 'SEALED' SHALL BE 1/2' JOINT EXPANSIVE MATERIAL. WITH A REMOVABLE TOP STRIP.. FILL VOID AFTER STRIP REMOVAL WITI -I A POURABLE URETHANE SELAANT TO MINIMIZE WATER INFILATRATION. MATCH SLAB COLOR ON NATURAL COLOR CONCRETE SLABS AND FINAL FINISH COLOR ON COATED INTERIOR SLABS. (0 N L() N N r- N) O N N CO a L v co 4J V CO N Ii O a 4Ca qt �N UY v _c U 0 ro Q 0 0 c U N 0 0 z N N 0 w z J 1 SHEET NO. Z 0 O 0 1/2' EXPANSION JOINT A PERIMETER OF INSIDE W =SLAB ON GRADE** 4' CONCRETE SLAB WITH Fl REINFORCING ON 6 MIL. VA AND 4' MIN. COMPACTED G FILL. PROVIDE I/2° SEALED JOINT AROUND ENTIRE SLA SAW CUT CONT J 8' NOMINAL CMU FOUND WALL TYP. 6 8' FOUNDA WALL DROPPED ONE BLOCK COURSE AT DOOR-WAY (THICKEN SLAB) ONG LL. ERMESH OR BARRIER NULAR EXPANSION PERIMETER 'WALL SECT ION CONCRETE SIDEWALK BY SITE CONCRETE CONTRACTOR TI-1 FIBERIE81 -1 VAPOR BARRIER :D GRANULAR SLED EXPANSION SLAB PERIMETER CROSS SECTION 4' BRICK LEDGE 3' -4 1 -0° DROP FOUNDATION WALL 8' FOR BEARING UNDER STOREFRONT ENTRANCE r cc1 8' NOM1N• BLOCK F' 8' 1=0UN f_ "SLAB ON GRADE** 4' CONCRETE SLAB WI REINFORCING ON to MI AND 4' MIN. COMPACT FILL. PROVIDE 1/2' SE JOINT AROUND ENTIRE (TYP.) SAW CUT CONTROL JOINTS -k-- SAW CUT CONTROL JOINTS IN 1'- 6'X1' -6 L --18' *4 SATT EARS .1•- 2 EACI-4 WAY I I s N .r......rAI...i. VAIVAI..:.. 1 1 FND. 1 DETAIL CROSS SECTION FND. DETAIL WALL SECTION to 2 X 4 STUDWALL 6 16° O.C. W/ 1/2' A -C PLYWOOD BOARD W/ MARLITE WALL FINISH BOARD (SEE ROOM FINISH SCHEDULE) 4' VINYL SASE 1/2' ANCHOR BOLT a 48` O.C. MAX. 4° CONC. SLAB ON 6 MIL. VAPOR BARRIER 4' COMPACTED GRANULAR FILL 8' -8` 3' -4' S' -4' SCALE: 1/2' =1'-e" 2` -0' 9' -Qf 5/8° 0.5.8. PLYWOOD ON 2 X 4 STUDWALL 16° OC:(EXTERIOR) THRU WALL FLASHING 4 WEEPI -IDLE 0 2' -0' O.C. 4° PROJECTED BRICK VENEER W/ 1' PROJECTING ROWLOCK COURSE 4° X 8' BLK. COURSE 12' X 8' HOLLOW CORE CONC. BLOCK 1/2° SEALED EXPANSION JNT, CONCRETE FOOTING W/ (2) +'4 CONT. REBARZ FOUNDATION DETAIL 44' -8' 0/0 MASONRY 5 8' NOMINAL CMU 3' -4' 5' -0' J` -4° ,BLOCK FOUNDATION DOWELED TO SLAB(S 6 EACH END OF CORRIDOR (TYPICAL) SCALE: 1/4' =1' -0' FOUNDATION f:LAN REAR POOL SLAB DECK BY POOL CONTR 9' -8' 1, 8' -8' 5` -0' 3' -4' 4° CONC. FLOOR SLAB ON 6 MIL. VAPOR BARRIER CONCRETE FOOTING W/ 2 *4 REBARS CONT. 1T -0' PLAN NORTI -W UNDATION PLAN 2 X 4 STUDWALL 0 16' O.C. W 1/2° A -C PLYWOOD 8D. 4 MARLITE WALL BOARD (AS PER RM. SPEC) 4' VINYL BASE (A5 PER RM. SPEC.) 1/2° EXPANSION FELT (SEALED) 5' -4' I 3' -4' 8' -8' 4' GRANULAR FILL BASE SCALE: 1/2 1/2' EXPANSION JOINT MATERIAL ALONG PERIMETER (BY POOL CONTR.) BRICK VENEER AS PER ALLOWANCE THROUGH WALL FLASHING WEEP HOLES 24' O.C. GRADE LINE (SLOPE AWAY, TYPICAL) 24'X1/2° DIA. ANCHOR BOLT 8' X 16' CMU BLOCK (TYPICAL) FOUNDATION DETAIL