HomeMy WebLinkAboutElectrical Plan E-1oE3 0 I 1 EXIT LIGH FIXTURE CEILING MOUNTED BAR INDICATES FACE 4 2 4 3 4 4 ro JUNCTION BOX MOTOR Q TELEPHONE OUTLET 0 SPEAKER ,1.4,IG 1,5 AMPERE RATED 3 -WIRE 120 VOLT DUPLEX RECEPTACLE U!1 WITH ISOLATED GROUND CONDUIT ABOVE FLOOR MARKS INDICATED NUMBER OF WIRES CONDUIT BELOW FLOOR —6— SPEAKER CONDUIT —T— TELEPHONE CONDUIT NOTE T.T.B. TELEPHONE TERMINAL BOARD (3/4' X 48`X96' PLYWOOD MOUNTED ON WALL READY TO RECEIVE TELEPHONE SERVICE MANUAL MOTOR STARTER WITI -f TI- IERMAL OVERL f 06 AND P PIOLO° LIGHT 630 30 AMPERE RATE 3 WIRE, 125/250 VOLT SINGLE RECEPTACLE WITH GROUND 650 50 AMPERE RATED 3 WIRE 125 250 VOLT SINGLE RECEPTACLE WITH GROUND wp DISCONNECT SWITCH 30 INDICATES AMPERAGE RATING WP INDICATES WEATHERPROOF NEMA 3R ENLOSURE. D A GFI 15 AMPERE RATED 3 -WIRE 120 VOLT DUPLEX RECEPTACLE WP WITH GROUND FAULT PROTECTION AND WEATHERPROOF CONVERPLATED HORIZONTALLY MOUNTED Q ELECTRICAL NOTES FLUORESCENT LIGHT FIXTURE D INDICATES FIXTURE TYPE FLUORESCENT LIGHT FIXTURE (EMERGENCY WALK THRU/ SECURITY) D INDICATES FIXTURE TYPE INCANDESCENT NIGH INTENSITY DISCHARGE LIGHT FIXTURE B INDICATES FIXTURE TYPE EXIT LIGHT FIXTURE CEILING MOUNTED -BAR INDCATES FACE 20 AMPERE RATED 120 /211 VOLT SINGLE POLE SWITCH 20 AMPERE RATED 120 211 VOLT TWQ POLE SWITCH 20 AMPERE RATED 120 211 VOLT TI -4REE WAY SWITCH 20 AMPERE RATED 120 211 VOLT FOUR WAY SWITCH 15 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND 15 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPT PROTECTION 20 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND PANEL. BOARD TELYISION OUTLET AREA SMOKE DETECTOR 15 AMPERE RATED 3-WIRE 120 VOLT DUPLEX RECPTACLE WITH GROUND, SPLIT WIRED CONSTANT AND CONTROLLED FLOOR BOX SEE SCHEDULE MANUAL FIRE ALARM PULL STATION DUCT SMOKE DETECTOR FIRE ALARM AUDIOVISUAL UNIT 15 AMPERE RATED 3 WIRE, 120 VOLT, DOUBLE DUPLEX RECEPTACLE WITH GROUND MULTI OUTLET PLUGMOLD 1 NOT ALL SYMBOLS ARE USED ON THIS PROJECT 2. ALL DEVICES AND COVERPLATES SHALL BE IVORY IN COLOR AND COVERPLATES SHALL BE FLEXIBLE NYLON UNLESS OTHERWISE INDICATED. ELEC. W.H. SECURE TO SOLID D ISCONN MANUAL MOTOR STARTER TYP OF 3) VERIFY LOCATION. NO REQD. 4 WIRING W/ POOL CONTR TIME CLOCK E -C TO CO- ORDINATE WIT14 WALL EXHAUST VENT (PENN P12R) 12' DIA. *125` SP 239 W, 120V, 1' DIA. W/ 12' X 12' ALUM. DUCT HP TO 12' X 12' PENN 'AIRETTE' TF-1RU ROOF ELECTRICAL METER 4 UNDERGROUND ELEC. SERVICE 111111111111111. ae 5. °t. S. 9. To TRANSFORM IN POOL- EQUIP. ELECTRICAL NOTES 7 7 SWITCHED FROM 1 POOL/MECH. ROOM PI- IOTOCELL ON RE OF BLDG. I IN W/ POOL CO TRACTOR) 7 LIGHT FIXTURES BY POOL CONTR, TO TIME CLOCK TO TIME CLOCK 3/4' DIA. PVC C. 4- 4 1- GND IVER.1 WP. (POP MACH GPI WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE. 4. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. TO J BOX 9 EA. UNDERWATER POOL LIGHT FIXTURE (4 REQD.) VERIFY, LOCATION, No. REQD. 4 2. FURNIGH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN. 3. PROPOSAL SHALL SE BASED ON SPECIFIED MATERIAL AND EQUIPMENT IN ORDER TO PROMOTE COMPETITION, BIDDERS ARE ENCOURAGED TO SUBMIT "ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND 1 OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGED AFFECTED BY ACCEPTANCE OFF ALTERNATES. VERIFY LOCAL CONDITIONS AT THE SITE. COMPLY WITH ALL APPLICABLE= CODES. SECURE AND PAY FOR ALL REQUIRED PERMITS. ELECTRICAL SYSTEM 51 -TALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE NEC. SYSTEM SHALL SE GROUNDED TO THE COLD WATER SERVICE ANt> TO THE BUILDING STEEL. FURNISH AND INSTALL A GROUND JUMBE:R WIRE ACROSS WATER METER ALL WIRES SHALL BE COPPER. MINUM SIZE *12 AUK*. ALL CONDUCTORS •10 AND SMALLER SHALL HAVE 'T1- 41.4N' TYPE INSULATION. CONDUCTORS LARGER THAN *10 SHALL HAVE 'THW' TYPE INSULATION. SCALE: 1/4' =1' -0 W .P. GPI WP. GPI. TO TIME CLOCK ELECTICAL PLAN TO OTHER FLOODS TO ADDITIONAL SITE LIGHTING (SEE SITE PLAN) 10. ALL EXPOSED WIRE, AND WIRING BELOW CONCRETE SLABS SHALL BE IN CONDUIT. FLEXIBLE ROMEX WIRING MAY BE USED FOR WIRING WITHIN WALLS. WIRING WITHIN THE POOL EQUIPMENT ROOM SHALL BE IN NON METALIC CONDUIT. 11. FURNISH AND INSTALL TYPE WRITTEN PANEL DIRECTORY, IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. 12. REFER TO ARCHITECTRUAL DRAWINGS FOR MOUNTING 14EIGHTS AND MOUNTING DETAILS FOR ALL FIXTURES AND EQUIPMENT, WHERE APPLICABLE. 13, 5WITCI -es 514ALL. BE MOUNTED 4' -0' ABOVE FLOOR. 14. RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED 18" ABOVE FLOOR UNLESS OTERUJISE NOTED. 15. ALL HEIGHT DIMENSIONS SHOWN ON PLANS OR INDICATED IN THESE NOTES SHALL BE THE CENTER OF THE DEVICE. 16. SUBMIT 4 COPIES OF SWOP DRAWINGS FOR EACH MAJOR PIECE OF EQUIPMENT TO THE ARCHITECT FOR REVIEW APPROVAL TO VERIFY COMPLIANCE WITH DESIGN. 11. FURNISH AND INSTALL 100 AMP 120/240 VOLT SINGLE PHASE TEMPORARY POWER WITH 6 -120 VOLT 20 AMP GFI RECPTACLES AND 2 -240 VOLT 20 AMP RECEPTACLES FOR CONSTRUCTION POWER. ELECTRICAL CONTRACTOR SHALL PAY FOR ALL FEES TO PROVIDE SERVICE. OWNER WILL PAY MONTHLY POWER BILLS. RECESSED FLUORESCENT FIXTURES (BETWEEN JOISTS) TO PAD MOUNT TRANSFORMER? IN- GROUND SERVICE NO SCALE: ssFLAN NOTESss T 12 V AC TRANSFORMER FOR UNDERWATER LIGHTING (LOCATE AS DIRECTED BY POOL CONTRACTOR) (TYP OF 4) (VERIFY NUMBER REQD)W/ POOL CONTRACTOR) 2 t 1LINC: EXHAUST FAN (PENN Z10) AND CFM 6 125 SF, 239 W, 120V, 1 °DIA, W/ 12' X 12' ALUM. DUCT UP TO 12' X 12' PENN 'AIRETE' THRU ROOF. 3 WALL. EXHAUST FAN PENN P12R) 12' DIA, 95 CFM .125" SF in W.P. 120, 120V, 1' DIA. FIZFIXED BLADE LOUVER COLOR SELECTED BY ARC1- IITECT 2' C.3. *3 4 I -*6 GND. PANEL 100AMP 120/240V ID1A,3W 30 CIRCU TS PANEL 1OWE ISER Di 1 AGRAM If 0 ILI z cU z 7 03 4) Q O C Ict N 432 W to i p <t z v 0 0 c U N 0 D a) "o _c c IZ 6 Z N N 0 CI N W O CO (0 Z 0 ee r-- Q U U of _.0,..OSm o°' Y� v C ,o* c —.e jq rr+ f .y h 9 r•° i�ei A t i+ f \des r ..i,. r 1. may. d in B LOB 6 B l� B Gs §�,a W 1 ELECTRICAL FIXTURE SCHEDULE 1 NO MANUFACT./ CAT MOUNT LAMPS BALLAST REMARKS FINISH A KICHLER K9691 BK. ISLANDER WALL 100 W ,A_ 120V PLASTIC SPHERE W/ BLACK FRAME 5 -MT -N- P DAYBIGHT FL6-11 -1" 1N GROUND 1151J METALHALIDE 120V MICRO FLOOD LIGHT G METALUX F240A RECESS FLANGE 2/ F40/ TS /CW 120V ELECT. BALLAST I X 4 STATIC FLOORESCENT TROFFLER LIGHT FIXTURE D METALUX 1 IA 240 CHAIN PENDANT 2/ F32/ TS /C11.1 120V ELECT. BALLAST 4' INDUSTRIAL LIGHT FIXTURE E 2 HEAD EXTERIOR ELECTRICAL FLOOD LIGHT FIXTURES SOFFIT SURFACE 2/ 150W PAR WHITE FINISH FIXTURE oE3 0 I 1 EXIT LIGH FIXTURE CEILING MOUNTED BAR INDICATES FACE 4 2 4 3 4 4 ro JUNCTION BOX MOTOR Q TELEPHONE OUTLET 0 SPEAKER ,1.4,IG 1,5 AMPERE RATED 3 -WIRE 120 VOLT DUPLEX RECEPTACLE U!1 WITH ISOLATED GROUND CONDUIT ABOVE FLOOR MARKS INDICATED NUMBER OF WIRES CONDUIT BELOW FLOOR —6— SPEAKER CONDUIT —T— TELEPHONE CONDUIT NOTE T.T.B. TELEPHONE TERMINAL BOARD (3/4' X 48`X96' PLYWOOD MOUNTED ON WALL READY TO RECEIVE TELEPHONE SERVICE MANUAL MOTOR STARTER WITI -f TI- IERMAL OVERL f 06 AND P PIOLO° LIGHT 630 30 AMPERE RATE 3 WIRE, 125/250 VOLT SINGLE RECEPTACLE WITH GROUND 650 50 AMPERE RATED 3 WIRE 125 250 VOLT SINGLE RECEPTACLE WITH GROUND wp DISCONNECT SWITCH 30 INDICATES AMPERAGE RATING WP INDICATES WEATHERPROOF NEMA 3R ENLOSURE. D A GFI 15 AMPERE RATED 3 -WIRE 120 VOLT DUPLEX RECEPTACLE WP WITH GROUND FAULT PROTECTION AND WEATHERPROOF CONVERPLATED HORIZONTALLY MOUNTED Q ELECTRICAL NOTES FLUORESCENT LIGHT FIXTURE D INDICATES FIXTURE TYPE FLUORESCENT LIGHT FIXTURE (EMERGENCY WALK THRU/ SECURITY) D INDICATES FIXTURE TYPE INCANDESCENT NIGH INTENSITY DISCHARGE LIGHT FIXTURE B INDICATES FIXTURE TYPE EXIT LIGHT FIXTURE CEILING MOUNTED -BAR INDCATES FACE 20 AMPERE RATED 120 /211 VOLT SINGLE POLE SWITCH 20 AMPERE RATED 120 211 VOLT TWQ POLE SWITCH 20 AMPERE RATED 120 211 VOLT TI -4REE WAY SWITCH 20 AMPERE RATED 120 211 VOLT FOUR WAY SWITCH 15 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND 15 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPT PROTECTION 20 AMPERE RATED 3 WIRE 120 VOLT DUPLEX RECEPTACLE WITH GROUND PANEL. BOARD TELYISION OUTLET AREA SMOKE DETECTOR 15 AMPERE RATED 3-WIRE 120 VOLT DUPLEX RECPTACLE WITH GROUND, SPLIT WIRED CONSTANT AND CONTROLLED FLOOR BOX SEE SCHEDULE MANUAL FIRE ALARM PULL STATION DUCT SMOKE DETECTOR FIRE ALARM AUDIOVISUAL UNIT 15 AMPERE RATED 3 WIRE, 120 VOLT, DOUBLE DUPLEX RECEPTACLE WITH GROUND MULTI OUTLET PLUGMOLD 1 NOT ALL SYMBOLS ARE USED ON THIS PROJECT 2. ALL DEVICES AND COVERPLATES SHALL BE IVORY IN COLOR AND COVERPLATES SHALL BE FLEXIBLE NYLON UNLESS OTHERWISE INDICATED. ELEC. W.H. SECURE TO SOLID D ISCONN MANUAL MOTOR STARTER TYP OF 3) VERIFY LOCATION. NO REQD. 4 WIRING W/ POOL CONTR TIME CLOCK E -C TO CO- ORDINATE WIT14 WALL EXHAUST VENT (PENN P12R) 12' DIA. *125` SP 239 W, 120V, 1' DIA. W/ 12' X 12' ALUM. DUCT HP TO 12' X 12' PENN 'AIRETTE' TF-1RU ROOF ELECTRICAL METER 4 UNDERGROUND ELEC. SERVICE 111111111111111. ae 5. °t. S. 9. To TRANSFORM IN POOL- EQUIP. ELECTRICAL NOTES 7 7 SWITCHED FROM 1 POOL/MECH. ROOM PI- IOTOCELL ON RE OF BLDG. I IN W/ POOL CO TRACTOR) 7 LIGHT FIXTURES BY POOL CONTR, TO TIME CLOCK TO TIME CLOCK 3/4' DIA. PVC C. 4- 4 1- GND IVER.1 WP. (POP MACH GPI WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE. 4. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. TO J BOX 9 EA. UNDERWATER POOL LIGHT FIXTURE (4 REQD.) VERIFY, LOCATION, No. REQD. 4 2. FURNIGH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN. 3. PROPOSAL SHALL SE BASED ON SPECIFIED MATERIAL AND EQUIPMENT IN ORDER TO PROMOTE COMPETITION, BIDDERS ARE ENCOURAGED TO SUBMIT "ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND 1 OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGED AFFECTED BY ACCEPTANCE OFF ALTERNATES. VERIFY LOCAL CONDITIONS AT THE SITE. COMPLY WITH ALL APPLICABLE= CODES. SECURE AND PAY FOR ALL REQUIRED PERMITS. ELECTRICAL SYSTEM 51 -TALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE NEC. SYSTEM SHALL SE GROUNDED TO THE COLD WATER SERVICE ANt> TO THE BUILDING STEEL. FURNISH AND INSTALL A GROUND JUMBE:R WIRE ACROSS WATER METER ALL WIRES SHALL BE COPPER. MINUM SIZE *12 AUK*. ALL CONDUCTORS •10 AND SMALLER SHALL HAVE 'T1- 41.4N' TYPE INSULATION. CONDUCTORS LARGER THAN *10 SHALL HAVE 'THW' TYPE INSULATION. SCALE: 1/4' =1' -0 W .P. GPI WP. GPI. TO TIME CLOCK ELECTICAL PLAN TO OTHER FLOODS TO ADDITIONAL SITE LIGHTING (SEE SITE PLAN) 10. ALL EXPOSED WIRE, AND WIRING BELOW CONCRETE SLABS SHALL BE IN CONDUIT. FLEXIBLE ROMEX WIRING MAY BE USED FOR WIRING WITHIN WALLS. WIRING WITHIN THE POOL EQUIPMENT ROOM SHALL BE IN NON METALIC CONDUIT. 11. FURNISH AND INSTALL TYPE WRITTEN PANEL DIRECTORY, IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. 12. REFER TO ARCHITECTRUAL DRAWINGS FOR MOUNTING 14EIGHTS AND MOUNTING DETAILS FOR ALL FIXTURES AND EQUIPMENT, WHERE APPLICABLE. 13, 5WITCI -es 514ALL. BE MOUNTED 4' -0' ABOVE FLOOR. 14. RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED 18" ABOVE FLOOR UNLESS OTERUJISE NOTED. 15. ALL HEIGHT DIMENSIONS SHOWN ON PLANS OR INDICATED IN THESE NOTES SHALL BE THE CENTER OF THE DEVICE. 16. SUBMIT 4 COPIES OF SWOP DRAWINGS FOR EACH MAJOR PIECE OF EQUIPMENT TO THE ARCHITECT FOR REVIEW APPROVAL TO VERIFY COMPLIANCE WITH DESIGN. 11. FURNISH AND INSTALL 100 AMP 120/240 VOLT SINGLE PHASE TEMPORARY POWER WITH 6 -120 VOLT 20 AMP GFI RECPTACLES AND 2 -240 VOLT 20 AMP RECEPTACLES FOR CONSTRUCTION POWER. ELECTRICAL CONTRACTOR SHALL PAY FOR ALL FEES TO PROVIDE SERVICE. OWNER WILL PAY MONTHLY POWER BILLS. RECESSED FLUORESCENT FIXTURES (BETWEEN JOISTS) TO PAD MOUNT TRANSFORMER? IN- GROUND SERVICE NO SCALE: ssFLAN NOTESss T 12 V AC TRANSFORMER FOR UNDERWATER LIGHTING (LOCATE AS DIRECTED BY POOL CONTRACTOR) (TYP OF 4) (VERIFY NUMBER REQD)W/ POOL CONTRACTOR) 2 t 1LINC: EXHAUST FAN (PENN Z10) AND CFM 6 125 SF, 239 W, 120V, 1 °DIA, W/ 12' X 12' ALUM. DUCT UP TO 12' X 12' PENN 'AIRETE' THRU ROOF. 3 WALL. EXHAUST FAN PENN P12R) 12' DIA, 95 CFM .125" SF in W.P. 120, 120V, 1' DIA. FIZFIXED BLADE LOUVER COLOR SELECTED BY ARC1- IITECT 2' C.3. *3 4 I -*6 GND. PANEL 100AMP 120/240V ID1A,3W 30 CIRCU TS PANEL 1OWE ISER Di 1 AGRAM If 0 ILI z cU z 7 03 4) Q O C Ict N 432 W to i p <t z v 0 0 c U N 0 D a) "o _c c IZ 6 Z N N 0 CI N W O CO (0 Z 0 ee r-- Q U U of _.0,..OSm o°' Y� v C ,o* c —.e jq rr+ f .y h 9 r•° i�ei A t i+ f \des r ..i,. r 1. may. d in B LOB 6 B l� B Gs §�,a W