Loading...
HomeMy WebLinkAboutTAC Submittal - G4.3SEASONAL SOIL PROTECTION CHART ARCI JAN. FEB. AMR. APR. MAY JUNE JULY AUG. SEPT. OCT. NOV. DEC. SE A 1/1/ /i /1 *,i SEEDING B B s. EEO NG r• E /1/�/ /1/. i• SODDING F /1 //V MULCHING 3 A KENTUCKY BLUEGRASS 100 LBS /ACRE,• CREEPING RED FESCUE 100 LBS /ACRE; PLUS 2 TONS STRAW MULCH /ACRE OR ADD ANNUAL RYE GRASS 20 LBS /ACRE FERTILIZE AS RECOMMENDED BY SOIL TEST. IF TESTING IS NOT DONE, APPLY 400 -600 LBS. /ACRE OF 12 -12 -12 ANALYSIS, OR EQUIVALENT, FERTIUZER. B KENTUCKY BLUEGRASS 120 LBS /ACRE; CREEPING RED FESCUE 120 LBS/ACRE; PLUS 2 TONS STRAW MULCH /ACRE, OR ADD ANNUAL RYE GRASS 30 LBS /ACRE FERTILIZE AS RECOMMENDED BY SOIL TEST. IF TESTING IS NOT DONE, APPLY 400 -600 LBS /ACRE OF 12 -12 -12 ANALYSIS, OR EQUIVALENT, FERTILIZER. C SPRING OATS 3 BUSHELS /ACRE FERTILIZE AS RECOMMENDED BY SOIL TEST. IF TESTING IS NOT DONE, APPLY 400 -600 LBS /ACRE OF 12 -12 -12 ANALYSIS, OR EQUIVALENT, FERTILIZER. D WHEAT OR RYE 2 BUSHELS /ACRE FERTILIZE AS RECOMMENDED BY SOIL TEST: IF ItSIING IS NOT DONE, APPLY 400 -600 LBS. /ACRE OF 12-12-12 ANALYSIS, OR EQUIVALENT, FERTILIZER. E FERTIU E A RECOMMENDED BY IF IS NOT DONE, APPLY 400 -600 LBS./ACRE OF 12 -12 -12 ANALYSIS, OR EQUIVALENT, FERTILIZER. F SOD 0 STRAW MULCH 2 TONS /ACRE /I/ s IRRIGATION NEEDED DURING JUNE JULY, AUGUST AND /OR SEPTEMBER dRRIGATION NEEDED FOR 2 WEEKS AFTER SUPPLYING SOD NO SCALE SEE PLANS FOR DIMENSIONS WAN VAIdit 101.40240 .1.410.41 II�TII�ITI�T�II II I ITf�. I -ITI� Il COMPACTED SUBGRADE GEOTEXTILE CONSTRUCTION ENTRANCE DETAIL MAINTENANCE: 1. INSPECT WEEKLY AND AFTER EACH STORM EVENT. 2. IF FABRIC IS TORN OR DETERIORATED, REPLACE IMMEDIATELY. 3. REMOVE SEDIMENT WHEN SEDIMENT IS CAUSING FABRIC TO SAG. 4. AFTER DRAINAGE AREA IS STABILIZED, REMOVE FABRIC AND SEDIMENT. INLET SILT PROTECTION DETAIL NTS INSTALL 8 OZ. NON -WOVEN GEOTEXTILE UNDER CASTING GRAVEL BAGS ARE HALF FULL WITH ROCK LARGER THAN THE INLET GRATE AND PACKED CLOSE TOGETHER TO ELIMINATE GAPS. IF BAG DETERIORATES OR IS DAMAGED, REBAG OLD BAG WITH CONTENTS INTO A NEW BAG. GRAVEL BAG CURB INLET PROTECTION SCALE: NTS OR INLETS THAT ARE IN LOW POINTS) MINIMUM 6" f2 STONE FILL WMI COMPACTED SOIL FLOW EMBED FILTER CLOTH MIN. 6' INTO GROUND rxr HARDWOOD OR 1.33 LB/FT STEEL POST FILTER ABRIC SECURE TO POSTS WITH 2' LATH IN SWALES Of? AREAS OF 4 RE WMI SILT FENCE DETAIL SCALE NTS TLF r MAX. SPACING BETWEEN POSTS IS 5' -0'. N A UNDISTURBED GROUND A V iktaiNIZE 1. INSPECT WEEKLY AND AFTER EACH STORM EVENT. 2. IF FABRIC IS TORN OR DETERIORATED, REPLACE SECTION IMMEDIATELY. 3. REMOVE SEDIMENT WHEN HEIGHT REACHES 1/3 OF OF THE HEIGHT OF THE FENCE OR IS CAUSING FABRIC TO BULGE 4. TAKE CARE NOT TO UNDERMINE THE ENTRENCHED FABRIC. 5. AFTER DRAINAGE AREA IS STABILIZED, REMOVE FENCE AND SEDIMENT, BRING DISTURBED AREA 10 GRADE AND STABILIZE I Ter Horst, Lamson Fisk, Inc. 8875 Pardue Rood l dlanapolo. RI 46286 Phone 317 334 -1500 Foxe 317- 334 -1552 Aj 1 11F PROJECT NO. 2001 379-04 CONSULTING ENGINEERS 0 0 0 w z W J J 0 U W I- 0 2 p cY m W Y 90 0 CC Z O 0 W I- Q CO COLLEGE WOOD ELEMENTARY SCHOOL 201101.02