Loading...
HomeMy WebLinkAbout03090026 C7.2 Site Details1_ 1 BLOCKING FOR PLUGS AND BENDS PIPE SIZE OUTSIDE FACE AREA (SQ. FT.) SIZE OF SIZE OF SUITE E PHDNE: 317 46241 FAX: 317 PLUG 90? 45? 22 1 /2?I 1 1/4? RUN BRANCH 20" 16 25 14 7 4 20" OR 16" MERIDIAN [ANAPOLIS, 12 16" 12 16 9 5 3 12" 7 z off. Lill 12 12" 9 5 4 gyp R. y �e,, N- -r PE880303 ii: I. STATE OF -0 4* IAN ♦'Si 8/ONAL -0N; lSS "I iu st1 R-A-P 4,____ DATE: 09/19/2003 5 10" 4 7 4 2 MICHIGAN ROAD RS, INDIANA 12„ OR LESS 12" 7 8" 3 5 3 DE] 1 10" 6 8" 4 6" fi 2 3 2 1 1 6" 4" 2 2 4" DWN BY: KRC C H KD. BY: R R H SCALE: NONE DATE: 09/19/03 PROJECT NUMBER 03 -188 DESIGN PHASE CONSTRUCTION PLAN NUMBER C7.2 SHEET OF UTILITY BLOCKING FOR PLUGS AND BENDS BLOCKING FOR PLUGS AND BENDS PIPE SIZE OUTSIDE FACE AREA (SQ. FT.) SIZE OF SIZE OF OUTSIDE FACE AREA (SQ. FT.) PLUG 90? 45? 22 1 /2?I 1 1/4? RUN BRANCH 20" 16 25 14 7 4 20" OR 16" 16 12 16" 12 16 9 5 3 12" 7 18» 12 12" 9 5 3 2 5 5 10" 4 7 4 2 1 12„ OR LESS 12" 7 8" 3 5 3 2 1 10" 6 8" 4 6" fi 2 3 2 1 1 6" 4" 2 2 4" 2 3 2 1 1 UTILITY MINIMUM COVER REQUIRED STORM SEWER 2.0 FT. (PAVEMENT AREAS) 1.5 FT. (LAWN AREAS) SANITARY SEWER 4.0 FT. WATER LINE 4.0 FT. GAS LINE 3.0 FT. TELEPHONE LINE 2.5 FT. (ELECTRIC LINE 2.5 FT. RUNNER ULTRA HIGH MOLECULAR WITH HIGH RESISTANCE TO ABRASION DURA SLIDE IS A CHEMICAL ULTRA HIGH MOLECULAR z RECEIVE OR BORE PIT EASEMENT 15' MIN 4) NOTE; ALL JOINTS IN CASING PIPE MUST BE RESTRAINED BACKFILL MATERIAL SHALL CONSIST OF APPROVED TRENCH SOIL PLACED IN MAXIMUM 8" THICK, LOOSE LIFTS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AND WITHIN ±3% OF ITS OPTIMUM MOISTURE CONTENT. EMERGENCY SPILLWAY AT 100 YEAR 813.92 PAVEMENT SUBGRADE OR FINAL GROUND SURFACE IN NON- PAVEMENT AREAS (ALLOW FOR MINIMUM 6" OF TOPSOIL) CASING SPACERS WEIGHT POLYMER AND SLIDE WEAR MODIFIED, FILLED, WEIGHT POLYMER. STAINLESS STEEL RIBBED FLANGE LINER PVC .090 THICK WITH 85-90 DUROMETER TOP OF CASING PIPE WELDING; STEEL CASING SECTIONS SHALL BE CONNECTED BY WELDING. WELD SHALL CONFORM TO AWWA C206. PIPE BEDDING MATERIAL SHALL CONSIST OF SAND PLACED IN MAXIMUM 3" THICK LOOSE LIFTS AND COMPACTED TO A POINT OF NON MOVEMENT BENEATH THE COMPACTING EQUIPMENT. z w n. DISTANCE OF BORE 1.5' FREEBOARD MIN TYPICAL BORING CASTING PIPE NOT TO SCALE 2' -O" O.D. MIN. '311,1/ :1ce '4 -4 L, v 3 MIN. O.D. 3 MIN. r-- GAS SERVICE LINE NOT TO SCALE co z z GAS SERVICE LINE ABBREVIATIONS D INSIDE DIAMETER O.D. OUTSIDE DIAMETER MIN. MINIMUM COVER REQUIREMENTS SPECIFY 0.0 OF CARRIER PIPE AND I.D. OF CASING PIPE TOP HALF BOTTOM HALF AS MEASURED FROM TOP OF PIPE TO FINAL GROUND SURFACE 12' MIN. POND CROSS SECTION PIPE CASING SPACER 3 SPACERS REQUIRED PER LENGTH OF PIPE PROTECTION AT ENDS OF CASING CASING SHALL HAVE BOTH ENDS BLOCKED JP IN SUCH A WAY AS TOPREVENT THE ENTRANCE OF FOREIGN MATERIAL, BUT ALLOWING LEAKAGE TO PASS 2' -0" 0.D. MIN. 10' NOT TO SCALE RECEIVE OR BORE PIT w z WATER SERVICE LINE 100 YEAR NEENAH CASTING R- 4215 -C TOR. 814.60 2 #4 BARS 36" LONG NON SHRINK GROUT MAX. OPENING 4" GREATER THAN 0.D. OF PIPE NON SHRINK GROUT HOLE VARIABLE 24" RCP PAVEMENT SUBGRADE OR FINAL GROUND SURFACE IN NON- PAVEMENT AREAS (ALLOW FOR MINIMUM 6" OF TOPSOIL) BACKFILL MATERIAL SHALL CONSIST OF APPROVED TRENCH SPOIL PLACED IN MAXIMUM 8" THICK, LOOSE LIFTS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AND WITHIN ±3% OF ITS OPTIMUM MOISTURE CONTENT. PIPE BEDDING MATERIAL SHALL CONSIST OF MSHTO NO. 57 STONE PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO AT LEAST 75% OF ITS RELATIVE DENSITY BELOW THE PIPE MID POINT. THE BEDDING MATERIAL PLACED ABOVE THE PIPE MID -POINT SHALL CONSIST OF MSHTO NO. 57 STONE (PLACED AND COMPACTED AS PREVIOUSLY DESCRIBED), OR SAND WHICH IS PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO A POINT OF NON MOVEMENT BENEATH THE COMPACTING EQUIPMENT. 4" DIA. TELEPHONE DUCT C, PROVIDE A MINIMUM OF 2 CONDUITS FOR BUILDING SERVICE 4' TO 8' 42" 30" PLAN VIEW 6" (TYP.) mmAgglintrik 1 6" MIN INV. 806.80 1 4-5- OQ CROSS SECTION POND OUTLET STRUCTURE #27 NOT TO SCALE IN 5" DIA. ELECTRICAL CONDUIT, MINIMUM SCHEDULE 80 PVC PIPE 5. THE CONTRACTOR SHALL CONSTRUCT THE UTILITY TRENCHES AND PROVIDE ADEQUATE SHORING (WHERE NECESSARY) IN CONFORMANCE WITH THE LATEST REQUIREMENTS FOR CONSTRUCTION STANDARD FOR EXCAVATIONS (29 CFR PART 1926.650 -.652 SUBPART P) PROMULGATED BY OSHA. 6. THE CONTRACTOR SHALL VERIFY THAT THE MINIMUM SPECIFIED PIPE COVER IS PROVIDED BETWEEN THE FINAL GROUND SURFACE AND TOP OF PIPE BEFORE LAYING PIPE. PROVIDE A MINIMUM OF 2 FT. OF COVER ABOVE PIPES DURING CONSTRUCTION. 7. THE TELEPHONE AND ELECTRIC CONDUIT WILL NOT SHARE THE SAME UTIUTY TRENCH WHERE THEY ARE SEPARATED AT THE MANHOLE /VAULT LOCATIONS. NORMAL POOL 807.00 TOPSOIL 4" COMPACTED #53 STONE 2' -0" 0.0. MIN. f` ter•+ t NOTES: 1. ALL MATERIALS EXCAVATED FROM THE UTILITY TRENCH SHALL BE STOCKPILED A MINIMUM SUFFICIENT DISTANCE FROM ALL TRENCHES TO PREVENT SLIDES OR CAVE -INS. 2. ALL BACKFILL MATERIALS SHALL BE APPROVED BY THE OWNER OR HIS REPRESENTATIVE BEFORE BEING PLACED. 3. THE AASHTO #57 STONE SHALL SATISFY THE REQUIREMENTS OF ADOT CONSTRUCTION AND MATERIALS SPECIFICATIONS. 4. THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT FOR THE BACKFILL MATERIALS SHALL BE DETERMINED BY ASTM D1557, AND THE RELATIVE DENSITY OF THE AASHTO #57 STONE SHALL BE DETERMINED BY ASTM 04253 AND ASTM 04254. 34 1/2"x34 1/2", 1" DEEP RECESS ORIFICE (10 -YEAR STORM) INV 812.75 16 DIA #4 REBAR AT 12" O.C., E.W. 4" MIN DETENTION AREA ORIFICE 807 (2-YEAR STORM) 3 N DIA ELECTRIC TELEPHONE SERVICE LINE NOT TO SCALE UNDISTURBED EARTH STRAP IRON ANCHORS 2" WIDE x 1/2" THICK 2,000 LB. MIN. CONCRETE BEDDING FOR TELEPHONE CONDUIT SHALL CONSIST OF SAND PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO A POINT OF NON- MOVEMENT BENEATH THE COMPACTING EQUIPMENT ENCASE ELECTRICAL CONDUIT IN CONCRETE THAT SATISFIES THE REQUIREMENTS OF THE CITY OF HUNTSVILLE. 5" DIA. ELECTRICAL CONDUIT, MINIMUM SCHEDULE 80 PVC PIPE NOT LESS THAN 0.6 x LAYING LENGTH "c OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 22 1/2' AND 11 1/4* BENDS PLAN UNDISTURBED EARTH 5" DIA. WASHER, 1" THICK 3/4" x 18" ANCHOR BOLTS (4 REQ'D) DOWNWARD BEND STANDARD HYDRANT SETTING: INSTALL HYDRANT 3' FROM RIGHT -OF -WAY LINE OR AS APPROVED BY WATER COMPANY. SET TOP FLUSH WITH FINISHED GRADE TO BE MARKED "WATER 3 -PIECE ADJUSTABLE VALVE BOX SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH VALVE FLANGED TO FITTINGS GATE VALVE PER AWWA C500 TO OPEN COUNTER CLOCKWISE NOTE: SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH VALVE FLANGED TO FITTINGS GATE VALVE PER AWWA C500 TO OPEN COUNTER CLOCKWISE 2,000 1.8. MIN. CONCRETE 2,000 LB. MIN. CONCRETE UNDISTURBED V \,A /v\ EARTH GATE VALVE AND BOX NOT TO SCALE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? AND 45? BENDS PLAN UNDISTURBED s EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE. SECTION "C -C" WATER MAIN CONCRETE BLOCKING NOT TO SCALE /V\ \\\/4; iv' i 1' -6" MIN. TO 2' -0" MAX. E DI ANCHORING COUPLING CONCRETE THRUST BLOCK ON UNDISTURBED EARTH CONCRETE THRUST BLOCK ON UNDISTURBED EARTH NOT LESS THAN 0.75 x LAYING LENGTH SET TOP FLUSH WITH FINISHED GRADE. TO BE MARKED "WATER" 3 -PIECE ADJUSTABLE VALVE BOX SLEEVE WATER MAIN 2,000 LB. MIN. CONCRETE 1r SECTION "D -D" FINISHED GRADE 0 MIN. 2,000 LB. MIN. CONCRETE UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR PLUGS. BREAK AWAY HYDRANT THREADS TO MATCH LOCAL FIRE DEPARTMENT EQUIPMENT PUMPER CONNECTION TO FACE TOWARD PAVEMENT 6" NOMINAL BARREL MIN. 1 CU YD. LOOSE STONE OR GRAVEL FOR DRAINAGE. (6" ABOVE PORTS) DO NOT USE CRUSHED LIMESTONE. 0.D. 1' -0" Min. (Typ.) CONCRETE THRUST BLOCK NOT TO COVER JOINTS OR DRIP HOLE REQUIRED ON 10" AND LARGER MAINS. OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR TEES AND WYES PLAN CONCRETE COLLAR GRADE K j\ NOTES; 1. WATER MAIN SHALL NOT BE LOCATED IN THE SAME TRENCH AS SANITARY SEWERS. 2. SEPARATION OF 3 FEET WITH ANY UTILITY REQUIRED. MINIMUM ANGLE OF INTERSECTION 45? a 4 10' PIPE OR BEND AS REQUIRED OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE NOTE: BENDS FITTINGS AS REQUIRED. SEE PLAN SHEETS FOR DETAILS. CONNECTION TO EXISTING WATER MAIN NOT TO SCALE 10' MIN. 3' WATER MAIN LAYING PARALLEL TO SEWER \9/ ``i V \Ay 'Y L WATER MAIN. \\'<W SANITARY OR STORM SEWER SEWER z NEW MAIN TAPPING SLEEVE VALVE BOX r1 10' WATER MAIN SEWER /WATER LINE SEPARATION NOT TO SCALE TRENCHED IN PLACE CLASS 150 MECH. JOINT D FLEXIBLE COUPLING DUCTILE IRON PIPE OR ADAPTOR CONC. COLLAR WATER MAIN CROSSING SEWER ANOTHER UTILITY FACILITY (TELEPHONE, GAS, ELECTRIC, ABLEVISION, ETC.) TYPICAL DEPTH OF WATER MAIN 1/2" TO 8" PIPE SHOULD HAVE 4 6" OF COVER, 10" AND LARGER PIPE SHOULD HAVE 4' OF COVER. D A EXISTING WATER MAIN FLEXIBLE COUPLING OR ADAPTOR AS CENTERLINE