Loading...
HomeMy WebLinkAbout1007009 10 C400 Utility Plan4- X a; 0 0 0 N 0 0 0 a.) 0 0 a_ c 0 0 m (1) 0 0 co l co co 0- �d 0 O tai 0 0 o co N CO CD p o 0 N U 0 0 0 r zm -I- 3 J 0 0 0 O_ 0 1 8" ROOF DRAIN INV. 836.00 fI 2" DOMESTIC WATER 6" FIRE PROTECTION a a 8" ROOF DRAIN INV. 836.00 PROPOSED BUILDING F.F.E.= 840.00 TYPE 1 C.O. INV. 835.00 4" SANITARY LATERAL 1 EXISTING RESTAURANT -12 "WTR -UE N, R 3 E EXISTING DETENTION POND 1 1 I TC 838.02 a 1 1 I INV. 831.39(E) I INV. 831.29(N) 1 INV. 831.39(5) j 1 I 0 INV. 834.00(W) 1I I 11 1 II 1 1 1 1 1 1 I 0 II 1 I1 I I1 1 I I 1 1 1 II 1 1i 1 I I 1 1 I 1 o 1 1 rr 1 1 I 1 1 1 11 1 1 1 1 1 -1 I WTR 1 11 1 20' WATER Flu EASEMENT 1 1 1 1 I I1 I 11 UT UTUE UTUE o I I UE L UT UE T1 r 12 'WTR SA- EIC OLIC 20' SANITARY SEWER ESMT. 10 -FT WIDE ASPHALT PATH 1 TC 838.30 1 INV. 834.25(E) I I II I 1 11 SD Sp 0 1 TC 837.45 7 -1 INV N 829.43 L_ INV S 829.50 0 SAN WIR- VTR -SD SD SD SD TC 838.28 INV. 833.06(E) INV. 832.96(N) O C== SAN 1 12 'WIT a 0 0 0 0 0 1 TC 837.85 INV. 829.13(W) INV. 829.23(S) INV. 832.10 (E) 1 TCI 837.02 INV 833.52(W IN\1. 834.50 15" RCP SD 10 LFIOF 12" SDI 1.00% 91 LFOF8 "SD 0 1.010X (MIN.) 1 1 12 "WTR 15LF F 12" SD 011.00% FDC j SAN 37 LF OF 8" SD 0 O 1.00% (MIN.) J I SD WTR 28 LF OF 12" SD 0 1.38% -G G G G G- 87 LF OF 18" SD 0 0.75% Q AN EX 1 TC 838.28 __J INV W 833.29 C 836.08 NV. 833.50(W) INV. 833.35 (E) WTR WTR 37 NV. 832.75(W) INV. 832.92(E) INV. 833.75(S) C 837.89 NV. INV. 834.50 14(N (SE) SAN. LATERAL CONNECTION (SEE DETAIL) INV. *825.25 SAN O�C WTR 63LFOF6 "SD 0 1.00% (MIN.) 38 LF OF 8" SD 0 1.00% (MIN.) TC 839.06 (EX INV W 825.38 INV E 825.44 0 WTR I '.465 165 LF OF 18" SD 0 0.50X �0 0 0�0 d; 'a PVC SANITARY LATERAL 0 1.00X (MIN.) TC 838.32 E 1 INV W 834.34 L E X J WEST 96th STREET -WTR -G- 1 IT Iw 4 CANOPY DOWNSPOUT C w O 11111•11111 OMNI!. D SECTION 833.75(W) EX TC 838.66 INV W 826.19 LEGEND EXISTING OO 0 EX. WV w UE -ETC -UET SAN GENERAL NOTES 0 IN=ly 20 40 I SCALE: 1 =20' CURB INLET STORM INLET STORM MANHOLE SANITARY MANHOLE CLEANOUT STORM STRUCTURE NUMBER SANITARY STRUCTURE NUMBER SANITARY SEWER STORM SEWER FIRE HYDRANT ASSEMBLY WATER VALVE POST INDICATOR VALVE WATER UNDERGROUND ELECTRIC TELEPHONE MANHOLE UT UNDERGROUND TELEPHONE c GAS TRANSFORMER re LIGHT POLE TELEPHONE PEDESTAL ELECTRIC, TELEPHONE CABLE OHE OVERHEAD ELECTRIC UNDERGROUND ELEC TELE TELEPHONE POLE 2. SANITARY SEWER PIPE AND FITTINGS MAY BE EITHER WITH A MINIMUM CELL CLASSIFICATION OF 12454 -B, IN ACCORDANCE WITH ASTM C -76, OR DUCTILE IRON AND AWWA C -151, OR HIGH DENSITY POLYETHYLENE 3344 33C. 60 PROPOSED 100 40 PN 8"WTR --UE -UT UET NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 1. ROOF DRAINS, FOUNDATION DRAINS, AND OTHER CLEAN WATER CONNECTIONS TO THE SANITARY SEWER SYSTEM ARE PROHIBITED. PVC THAT CONFORMS TO ASTM D -3034, SDR 35 OR REINFORCED CONCRETE PIPE CLASS III, IV, OR V PIPE CONFORMING TO ANSI SPECIFICATIONS A21.51 PIPE CONFORMING TO ASTM -3350 CELL CLASS P.E. 3. WATER MAINS CROSSING ANY AND ALL SEWERS SHALL HAVE A MINIMUM VERTICAL SEPARATION OF 18" BETWEEN THE OUTSIDE OF THE WATER MAIN PIPE AND THE SEWER PIPE. ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF THE CROSSING SUCH THAT BOTH JOINTS WILL BE EQUIDISTANT AND AS FAR AWAY FROM THE SEWER AS POSSIBLE. IF WATER LINE(S) CROSS BELOW SANITARY SEWER LINE(S), SEWER LINE MUST BE CONSTRUCTED OF EITHER DUCTILE IRON PIPING OR OF 200 psi PVC (SDR -21 OR EQUIVALENT) FOR THAT PARTICULAR SPAN. 4. EXISTING UNDERGROUND UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS ACCORDING TO THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF THE EXISTING UTILITIES AND REPAIRING ANY DAMAGE DONE TO THE UTILITIES DURING PROBING OR CONSTRUCTION. TO OBTAIN ACCURATE FIELD LOCATIONS OF EXISTING UNDERGROUND UTILITIES, THE CONTRACTOR SHALL NOTIFY THE FOLLOWING FORTY-EIGHT (48) HOURS IN ADVANCE: INDIANA UNDERGROUND CABLE LOCATION 1- 800 382 -5544. 5. ALL STORM DRAINAGE CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL STORM SEWER SPECIFICATIONS AND REQUIREMENTS. 6. FIELD TILE ENCOUNTERED SHALL BE REPLACED AND /OR CONNECTED TO THE STORM SEWER SYSTEM. 7. SIDE SLOPES 3:1 OR GREATER WILL BE SODDED OR STABILIZED WITH AN EROSION CONTROL BLANKET. 8. ALL EARTHEN AREAS DISTURBED DURING CONSTRUCTION SHALL HAVE TEMPORARY SEEDING AND MULCHING. 9. SILT FENCE AROUND STRUCTURES IN PAVEMENT AREA ARE TO BE INSTALLED PRIOR TO PAVING CONSTRUCTION. 10. GRANULAR BACKFILL REQUIRED FOR ALL PIPE UNDER PAVEMENT AND WITHIN 5 FEET OF PAVEMENT. 11. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AT HIS EXPENSE ALL AUTOMOBILE AND PEDESTRIAN TRAFFIC CONTROL DEVICES REQUIRED BY FEDERAL, STATE, COUNTY, CITY OR LOCAL AGENCY. THE AMOUNT, LOCATION AND SIZE SHALL BE PER DIRECTION OF AGENCY. 12. FIRE HYDRANTS: SHALL BE MUELLER (SAFETY YELLOW, M.A.B. #0433291, SHERWIN WILLIAMS #F75YP2) (CARMEL CLAY SPEC. HYDRANTS SHALL BE OPEN RIGHT AND HAVE A SAFETY BLUE STRIPE AROUND BONNET FROM THE FACTORY). THE HYDRANT PUMPER NOZZLE SHALL BE ONE -PIECE DESIGN, COMPATIBLE WITH 5" STORZ HOSE COUPLING. THE NOZZLE SHALL BE AN INTEGRAL PART OF THE FIRE HYDRANT AND MUST BE FURNISHED BY THE MANUFACTURER OR AUTHORIZED DISTRIBUTOR DESIGNATED BY THE MANUFACTURER. MUELLER MODEL 290220 FOR CASTING AND 290221 FOR CAP. STORZ ADAPTERS WILL NOT BE ACCEPTED. 13. BLUE REFLECTIVE WARNING TAPE MUST BE INSTALLED 18" ABOVE ALL WATER MAINS. TRACER WIRE MUST BE INSTALLED WITH ALL WATER MAIN LAID IN CARMEL. 14. THE DEVELOPER SHALL VERIFY THE ELEVATIONS OF THE EXISTING UTILITIES AND DESIGN PLANS ACCORDINGLY. EXISTING INFRASTRUCTURE SHALL NOT BE MOVED TO ACCOMMODATE NEW DEVELOPMENTS. 15. POSI -CAPS OR THE EQUIVALENT ARE REQUIRED ON ALL WATER VALVE INSTALLATIONS. 16. CONTRACTOR WILL NEED TO CALL FOR AN ON SITE MEET WITH THE INSPECTOR PRIOR TO WATER MAIN INSTALLATION. 17. CONTRACTOR SHALL PAY ALL REQUIRED BACTERIOLOGICAL LAB SERVICES 18. AS -BUILT SURVEY (PAPER DIGITAL) SHALL BE SUPPLIED FOR WATER MAIN EXTENSION BY CONTRACTOR. DON'T DIG BLIND "HOLEY MOLEY" 1-800-382-5544 CALL TOLL FREE 0 iS) #c f) 0 P Q��o\�C Q z SHEET NO. C400 O z I- c W 0 o. O N O E- Q 0 Lo co z C 0 0 0 0