Loading...
HomeMy WebLinkAboutA1.1.pdf date: project: date: drawn: checked: scale: revision: description: coord.: 1008 August 19, 2010 As noted JM JM JM Carmel, In 5/8" GYPSUM BOARD 3-5/8" 20 GA STEEL STUDS @16" O/C 5/8" GYPSUM BOARD EXSTEND TO 12'-4" A.F.F. 5/8" GYPSUM BOARD 3-5/8" 20 GA STEEL STUDS @16" O/C 5/8" GYPSUM BOARD EXSTEND TO DECK ABOVE 5/8" GYPSUM BOARD 3-5/8" 20 GA STEEL STUDS @16" O/C EXSTEND TO 12'-4" A.F.F. 5/8" GYPSUM BOARD 3-5/8" 20 GA STEEL STUDS @16" O/C EXSTEND TO DECK ABOVE 12760 Horseferry Road Suite 200, Carmel, IN 46032 317-574-9408 Code Occupancy Construction Type INDIANA BUILDING CODE, 2008 EDITION Office B Type V-B sprinkled Nonseparated Uses AREA WIRING, RUNS, CIRCUITS and setting panel. ELECTRICAL SYSTEM. SERVICES SHALL INCLUDE THE SIZING OF 1. CONTRACTOR SHALL PROVIDE DESIGN-BUILD SERVICES FOR THE NEW WORK SHALL INCLUDE REVIEWING SYSTEM WITH ARCHITECT, AND THE OBTAINING OF ALL PERMITS REQUIRED FOR CONSTRUCTION. 2. Plan notes ALARM CONTROL PANEL DIMMER, 3-WAY, HEIGHT S SWITCH FIXTURE DESIGNATION ROOM NUMBER WINDOW/LOUVER DESIGNATION DETAIL NUMBER SHEET NUMBER can light CEILING HEIGHT ENLARGED PLAN/PLAN DETAIL DOOR REFERENCES WALL MOUNTED LIGHT FIXTURE THERMOSTAT SMOKE DETECTOR EXHAUST FAN RETURN AIR GRILLE CEILING DIFFUSER NEW WALL AND DOOR PLAN NOTE EQUIPMENT REFERENCE WALL SECTION REFERENCE DETAIL REFERENCE X-XXX X X-XXX X INTERIOR ELEVATION A-XXX X 000 X-XXX X WALL TYPE /sUB TYPE 240 VOLT OUTLET AT 16" AFF UNLESS NOTED OTHERWISE PHONE /DATA JACK AT 16" AFF UNLESS NOTED OTHERWISE. (3/4" C TO ABOVE CEILING) CABLE TELEVISION JACK AT 16" AFF UNLESS NOTED OTHERWISE. (3/4" C TO ABOVE CEILING) 2'x4' light ceiling MOUNTED FIXTURE existing wall CFM REQUIRED S SWITCH AT 44" AFF UNLESS NOTED otherwise 120 VOLT 3 PRONG DUPLEX OUTLET AT 16" AFF UNLESS NOTED OTHERWISE FIXTURE DESIGNATION CONDITIONS SHALL BE IMMEDIATELY IDENTIFIED TO THE ARCHITECT'S WITH THE OWNER PRIOR TO COMMENCING WORK CONTRACTOR SHALL CARRY STATUTORY INSURANCE COVERAGE AND SHOW PROOF OF COVERAGE TO THE ARCHITECT AND OWNER. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES CONTRACTOR SHALL WARRANTY THE WORK FOR A PERIOD OF ONE YEAR OR AS REQUIRED BY SPECIFICATIONS OF STATE LAW, WHICHEVER IS LONGER. OFFICE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. PLAN DIMENSIONS ARE TO CENTERLINE OF WINDOWS, DOORS AND COLUMNS NOTED OTHERWISE AND TO FINISH FACE OF EXISTING WALLS. PLAN DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS STATE AND LOCAL ORDINANCES. DO NOT SCALE DRAWINGS. ANY DESCREPANCIES ON THE CONSTRUCTION THE LATEST EDITION OF THE INDIANA AMENDMENTS AND ALL FEDERAL, WORK SHALL COMPLY WITH THE 2008 INDIANA BUILDING CODE AND RESPONSIBILITIES OF THE CONTRACTOR. SPECIFICATIONS AND SHALL GOVERN THE DUTIES , OBLIGATIONS, AND INSTITUTE OF ARCHITECTS SHALL HEREBY BECOME PART OF THESE THE "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION OF A DOCUMENTS OR BETWEEN THE CONSTRUCTION DOCUMENTS AND FIELD SMALL PROJECT" (A105, 2007 EDITION) AS PUBLISHED BY THE AMERICAN 132546978 1. THE CONTRACTOR SHALL PROVIDE DESIGN-BUILD SERVICES FOR THE FIRE SUPPRESSION SYSTEM. SERVICES SHALL INCLUDE THE RE-ROUTING OF EXISTING LINES TO ACCOMMODATE NEW BUILD OUT, USING CONCEALED SPRINKLER HEADS in dropped ceiling. 2. CONTRACTOR SHALL REVIEW PROPOSED PLAN WITH ARCHITECT PRIOR TO COMMENCING WORK. 3. WORK SHALL INCLUDE THE PREPARATION OF DRAWINGS, REVIEWING SYSTEM WITH ARCHITECT, AND THE OBTAINING OF ALL PERMITS REQUIRED FOR CONSTRUCTION. a. full thickness sound attenuation blankets wall sub types all interior walls shall be type 1 unless noted. TENANT IMPROVEMENT FOR PRUDENTIAL iNSURANCE SUITE 150 Regents Building 12775 horseferry road, Carmel , IN Ø 1. 1.1 22.1