The City has received your comment letter dated September 23, 2010 based upon the City review of
August 16, 20I0.
The comments from the City review have been satisfactorily addressed with the following exceptions:
CONSTRUCTION DRAWING REVIEW COMMENTS
2. Sheet C300.
b. There does not appear to be a change in the alignment of the ADA ramps between
buildings 44 and #7.
e. Thank you for your response. No ADA spaces are marked. Are ADA spaces proposed in
the on- street parking west of buildings #8 and 99?
h. Please comment on the adequacy of the proposed drive aisle width to accommodate
maneuvers into and out of the parking spaces.
i. The drive aisle is not a consistent width. Since this area is in the right -of -way, it is
desired to minimize the amount of pavement and make the island larger so the drive aisle
is a consistent width.
j. Thank you for your response. What is the status of this analysis?
k. Please ensure the detail legend on Sheet C300 references the College Avenue right -of-
way section. It is not clear that this specific section is required.
m. Please provide a roadway cross section for the College Avenue improvements in addition
to the pavement cross sections. The cross section needs to include the median work, the
northbound travel lane, the island, and the parking spaces.
n. Is there a commitment in place for this future right -of -way dedication?
3. Sheet 301.
b. Have the FFE's been established based on an analysis of the on -site flood route?
e. Thank you for your response. We are concerned about the adequacy of the 18" pipe out
of the existing structure on the east side of the southbound travel lane (structure run 202-
201- existing inlet).
4. Are Details 10 -20 and 10 -21 proposed within the right -of -way?
Based on additional review, the Department provides additional comments:
Structure 306 needs to be farther away from the pavement edge. It appears that it would be
best located at the corner of the new island.
Please revise the median opening such that the nose is farther south, preventing left turning
movements from the commercial drive to the west.
Dr_r>:1xr;�IF r oi l �cr r. Iiltl t�
O tt CIVIC SQ1 ARF. CIA161FL. IN 46032 Oi+ict; 317.571.24-11 FAX 317.771.2439
MAI1. enginernn,xc:u'mel iii nr
JANIES BRMNARD, MAYOR
Mr. Edward E. Fleming.
November 10, 2010
RE: 1 I O Centre Apartment Holnes- Project Review #2
Page 2 of 2
If you have questions, please contact me at 571 -2441.
Sincerely,
ry R Du an Jr., P.E.
Assistant City ngineer
Department of Engineering
cc: Angelina Conn, Department of Community Services
John Duffy, Carmel Utilities
Paul Pace, Carmel Utilities
Paul Amone, Carmel Utilities
Greg Hoyes, Hamilton County Surveyor's Office
Greg Ilko, Crossroad Engineers, PC
Department Review/File Copy
isswappsluser datalz:lshared\DHILLIPRO.tREV 1 Ol l 1 6THCENTREAPAt27'MEN'rHOMESREV #2