Loading...
HomeMy WebLinkAbout23 C803 Storm Sewer Detailsr PROJECT NO.: 1299.004 CHECKED BY: SHEET TITLE: STORM SEWER DETAILS i t SHEET NO.: 1 33 1 DATE: PROJECT NO.: 1299.004 DRAWN BY: DCC CHECKED BY: SHEET TITLE: STORM SEWER DETAILS DRAWING FILES: N:\1299\004\DWGS\SEC 1B \C803.DWG SHEET NO.: 1 33 EXISTING RIPRAP w /FlLTER FABRIC APPROXIMATELY 12" DEEP, WIDTH VARIES. EXISTING LAKE BANK CROSS SECTION B-B 100 YEAR FLOOD ELEVATION =899.3 (WEST POND) 898.9 (EAST POND) EXISTING POND ELEV.= 899.0± PROPOSED POND ELEV. =898.0 100 YEAR FLOOD ELEVATION =899.3 (WEST POND =898.9 (EAST POND) PROPOSED LAKE BANK IN AREAS WHERE LAKE IS PROPOSED TO BE RELOCATED. Grooved end on outlet end tongue end on inlet end Groove (or tongue) tom be the some as on standard reinforced concrete pipe ASTM designation C76 I A CLASS 'A' CONCRETE LONGITUDINAL SECTION J ROLL CURB GUTTER BASE NEENAH TYPE CASTING NO. R- 3501— (TL —TR) T.C. or NO. R- 3501 —N r ASPHALT COMPUTED LENGTH OF CULVERT PAY LENGTH I END SECTION OF CULVERT LENGTH (D) SECTION A —A DIMENSIONS OF CONCRETE END SECTIONS FOR ROUND PIPE DIA T A C D E* K R1 R_ APPROX. (MIN) 1 WEIGHT 12" 2" 5" 4' -3" 6' -2" 2' —O" 1.3 1 r 1 /8" 9" 800 15" 2 1 /4" 7" 4' -0" 6' -3" 2' -6" 1.5 12 1 /2" 11 1,100 18" 2 1/2" 11" 4' -1" 6' 3' -0" 1.8 15 1/2" 12" 1,300 21" 2 3/4" 11" 3' -6" 6' -3" 3' -6" 2.1 16 1/8" 13 1,500 24" 3" 1' —O" 2' -8" 6' -3" 4' —O" 2.3 16 3/16" 1 1,800 27" 3 1/4" 1' -1" 2' -5" 6' -3" 4 6" 2.6 18 1/2" 14 1/2" 2,100 30" 3 1 /2" 1' -2" 1' -10" 6' -3" 5' -0" 2.9 1 C. 3/16" 15" 2,400 33" 3 3/4" 1' -3" 3' -6" 8' -3" 5' -6" 3.1 18 1/2" 17 1/2" 4,100 36" 4" 1' -5" 3' -1" 8' -3" 6' —O" 3.4 23 3/4" 20" 4,200 TOLERENCE 1" RIP RAP TO BE PLACED ON SIDE SLOPE WHEN CALLED FOR ON PLANS DIMENSIONS NCHES) A B C (MAX) (I.D.) (MIN) 12 36 18 15 36 21 18 48 25 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 DIMENSIONS NCHES) A B C (MAX) (I.D.) (MIN) 12 36 18 15 36 21 18 48 25 21 48 28 24 48 .31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 r ASPHALT BEEHIVE INLET NEENAH TYPE CASTING No. R -4342 STRAIGHT CURB GUTTER NEENAH TYPE CASTING NO. R -3010 STANDARD HYDRO SEEDING W /STRAW MULCH TACKIFIELD TRENCH AREA CLASS I CLASS II CLASS III CLASS IV BEDDING FLAT SHOVEL 85% 90% UNDISTURBED BOTTOM HAUNCH 85% 90% NO INITIAL BACKFILL NO COMPACTION 85% 90% NO NOTE: IF CLASS I MATERIAL IS USED FOR BEDDING, IT MUST ALSO BE USED FOR HAUNCHING. 1/2 TRENCH DEPTH MIN. STORM SEWER TRENCH PIPE EMBEDMENT DETAIL REQUIRED COMPACTION TABLE STANDARD PROCTOR DENSITY (ASTM D 2321) BACKFILL MATERIAL (SEE NOTE) (GRANULAR MATERIAL TO BE USED UNDER ALL 1 PAVED AREAS) 1 6" "B" BORROW DIMENSIONS (INCHES) A B C (MAX) (1.0.) (MINI) 12 48 MIN. 18 15 48 MIN. 2.1 18 48 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 NOTE BACKFILL MATERIAL CLASS I, II, III, IV OF THE U.S.C.S. SOIL CLASSIFICATION SYSTEM. ROLL CURB GUTTER NEENAH TYPE CASTING NO. R- 3501— (TL —TR) or NO. R- 3501 —N ASPHALT ROLL CURB GUTTER NEENAH TYPE CASTING NO. R- 3501 —TL —TR ASPHALT S -150 EROSION CONTROL BLANKET AS MANUFACTURED BY NORTH AMERICAN GREEN U) 0 0 N 0 0 V 0 0 N cn o c g U CD W c Oottiiiitonuo K SEX7 O� ti G�S ERF Q.�fi AI_ -0 9500028 STATE OF �4✓` IF$'O /NDIANP. t lrirur1111 DATE: 06/09/04 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. COPYRIGHTED BY THE SCHNEIDER CORP. (2004) ‘b Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS *LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering