HomeMy WebLinkAbout13 C302 121st Street Maintenance of Traffic Plant
I
DURA BUILDERS, INC.
CARMEL, INDIANA
DRAWN BY:
kwk
CHECKED BY:
SHEET TITLE:
121ST STREET
MAINTENANCE OF TRAFFIC PLAN
DRAWING FILES:
N: \1299 \004 \DWGS \SEC 1B \C302.DWG
XREF: 004 -1 A— BS.DWG
XREF: 1299002S.DWG
XREF: 004 -1B— BS.DWG
XREF: 005 BS.DWG
SHEET NO.:
C302
is
L,
DATE:
PROJECT NO.:
1299.004
DRAWN BY:
kwk
CHECKED BY:
SHEET TITLE:
121ST STREET
MAINTENANCE OF TRAFFIC PLAN
DRAWING FILES:
N: \1299 \004 \DWGS \SEC 1B \C302.DWG
XREF: 004 -1 A— BS.DWG
XREF: 1299002S.DWG
XREF: 004 -1B— BS.DWG
XREF: 005 BS.DWG
SHEET NO.:
C302
Li.
20.00'
STOP SIGN
(R1 -1)
160'
12" WIDE SOLID YELLOW STRIPE
SPACED AT 20' c.c.
50' TAPER
20.00' 8 32.00'
8" WIDE SOLID YELLOW STRIPE
DIRECTIONAL ARROW (TYP)
4" SOLID WHITE STRIPE
500'
8" WIDE SOLID YELLOW STRIPE
12" WIDE SOLID YELLOW STRIPE
SPACED AT 20' o.c.
r
SCALE 1"=100'
N
T
N
SCALE 1"=100'
121st STREET
25
500'
1
STRIPING PLAN
SCALE 1"=50'
100.00'
8" WIDE SOLID YELLOW STRIPE
12" WIDE SOLID YELLOW STRIPE
SPACED AT 20' c.c.
STRIPING PLAN
SCALE 1"=50'
MAINTENANCE OF TRAFFICE AND CONSTRUCTION SIGN LAYOUT
121st STREET
1 T T
1-- ---J
L
MAINTENANCE OF TRAFFICE AND CONSTRUCTION SIGN LAYOUT
12" WIDE SOLID YELLOW STRIPE
SPACED AT 20' o.c.
NOTE:
ALL PAVEMENT MARKINGS TO BE THERMOPLASTIC.
121st STREET
NOTE:
ALL PAVEMENT MARKINGS TO BE THERMOPLASTIC.
T
400'
C
O
113 BARRICADES 0 25 1800'
F
4" SOLID WHITE STRIPE
0
0
0
98
i
ASSUMED NORTH
MAINTENANCE OF TRAFFIC LEGEND
ROAD CONSTRUCTION SIGN WITH: TYPE "A"
CONSTRUCTION WARNING LIGHT
(LOW INDUSTRIAL FLASHING)
BARREL
N
NEW PAVEMENT
ROAD CONSTRUCTION AHEAD (XW2O-1); 48 "x48"
END CONSTRUCTION (XC2O-1); 60"x24"
FLAGGER AHEAD (XW2O-7)
FLAGGER REQUIRED
N
DIRECTION OF TRAFFIC
N
N
N
8" WIDE SOLID YELLOW STRIPE
HOLEY MOLEY SAYS
e( DON'T
DIG
BLIND"
"IT'S THE LAW"
CALL 2 WORKING DAYS BEFORE YOU DIG
1- 800- 382 -5544
CALL TOLL FREE
PER INDIANA STATE LAW IS -69 -1991.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
w
8" WIDE SOLID YELLOW STRIPE
CONSTRUCTION GRADE
O
Li
DIRECTIONAL ARROW (TYP)
32.00' 8' 20.00' 20.00'
O
W
CO
w
(f)
O
Li
50' TAPER
WIDE SOLID YELLOW STRIPE
c
1. IT SHALL BE THE RESPONSIBILITY OF EACH SUBCONTRACTOR TO VERIFY ALL
EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT
SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY TO CONTACT THE
OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS OF EACH
UTILITY BEFORE WORK IS STARTED. THE SUBCONTRACTOR SHALL NOTIFY, IN
WRITING, THE OWNER AND THE ENGINEER OF ANY CHANGES, OMISSIONS, OR
ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR
RESUMED.
2. ALL CONSTRUCTION ACTIVITY ON THIS SITE IS TO BE PERFORMED IN
COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY.
3. ALL CONSTRUCTION INSIDE PUBLIC RIGHT —OF —WAY SHALL BE PERFORMED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE INDIANA DEPARTMENT OF
TRANSPORTATION (INDOT) FOR CONSTRUCTION INCLUDING MATERIALS, METHODS
OF CONSTRUCTION, AND TRAFFIC CONTROL.
4. MAINTENANCE OF TRAFFIC DEVICES ARE TO CONFORM TO INDIANA DEPARTMENT
OF TRANSPORTATION STANDARD SPECIFICATIONS, (LATEST EDITION). FOR MORE
DETAIL SEE INDIANA DEPARTMENT OF TRANSPORTATION STANDARD DRAWINGS.
5. ALL TRAFFIC CONTROL METHODS AND PROCEDURES AND LAYOUT, AS DETERMINED
BY THE CONTRACTOR, SHALL BE IN COMPLIANCE WITH LOCAL REQUIREMENTS
AND THE INDIANA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS
AND HIGHWAYS, LATEST EDITION.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY COUNTY HIGHWAY DEPT.
BEFORE ANY ROAD CONSTRUCTION IS TO BEGIN.
7. THE CONTRACTOR SHALL FURNISH, INSTALL AND MAINTAIN IN PROPER WORKING
ORDER, ALL CONSTRUCTION SIGNS, LIGHTS, BARRELS AND OTHER TRAFFIC
CONTROL EQUIPMENT AS MAY BE REQUIRED TO FULLY MAINTAIN, AS NEARLY
AS POSSIBLE, NORMAL TRAFFIC WITHIN THE CONSTRUCTION AREA.
CONSTRUCTION SIGNS SHALL REMAIN IN PLACE UNTIL ALL ROAD CONSTRUCTION
IS COMPLETE.
8. THE CONSTRUCTION WILL CONSIST OF ADDING AN ACCELERATION/DECELERATION
LANE WITH BARREL ARRAYS AND SIGNS POSTED AT EACH END OF THE WORK
ZONE AS SHOWN ON THE PLAN. UPON COMPLETION OF WORK THE BARRELS WILL
BE REMOVED.
9. CONSTRUCTION HOURS IN THE COUNTY RIGHT —OF —WAY WILL BE ONLY FROM
9:00 A.M. TO 4:00 P.M., OR AS AUTHORIZED BY THE COUNTY HIGHWAY DEPT.
10. DURING NON CONSTRUCTION HOURS, 121st STREET WILL BE OPENED FOR PUBLIC
USE. THIS WILL REQUIRE THAT THE BARRELS BE MOVED TO THE EDGE OF THE
EAST BOUND LANE.
11. FLAGGER AHEAD SIGNS TO BE COVERED OR TAKEN DOWN WHEN FLAGGERS NOT
PRESENT.
12. ANY DROP OFF ADJACENT TO THE TRAVEL LANE WHICH EXCEEDS 4" MUST HAVE
TYPE II DRUMS WITH TYPE 'A' FLASHERS SPACED EVERY 100'.
C'7 ;1
j j \N
Barricade Placement
A During Construction
B At the End of Construction Day
EXISTING PAVEMENT
0
L-
a)
0
0
U
0
C
-d L�
0
�o
z
O N
6 o
w
N
A
GAS �RF 4,
No.
950002
STATE OF
/NDIAN
S r
O NAL
NII I INlull\
K
DATE: 06/09/04
THIS DRAWING AND THE IDEAS, DESIGNS AND
CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF THE SCHNEIDER
CORPORATION, AND ARE NOT TO BE USED OR
REPRODUCED, IN WHOLE OR IN PART, WITHOUT
THE WRITTEN CONSENT OF THE SCHNEIDER
CORPORATION.
COPYRIGHTED BY THE SCHNEIDER CORP. (2004)
Schneider
THE SCHNEIDER CORPORATION
12821 E. New Market Street
Suite 100
Carmel, IN 46032
Telephone: 317.569.8112
Fax: 317.826.6410
www.schneidercorp.Corn
Architecture
Civil Engineering
Environmental Engineering
Geotechnical Services
GIS *LIS
Home Builder Services
Interior Design
Land Surveying
Landscape Architecture
Transportation Engineering
CONTINUATION