Loading...
HomeMy WebLinkAboutC600 Storm Sewer Plan & ProfileCURB INLET TABLE STRUCTURES STRUCTURES ANGLE AND tt LESS THAN 48" GREATER THAN QUALITY OF PIPES CURB CASTING PIPE FROM T/C TO 48" FROM T/C WILL REQUIRE STEPS CASTING *3501 TL SIZE INVERT TO INVERT SPECIAL DESIGN REQUIRED *R-3501 N TR 12" to 18" 2'X2' DESIGN APPROVAL, No Yes Yes DESIGN 18" or 21 MH APPROVAL Yes Yes Yes DESIGN c3 No No Yes 21 or 27' 2' x3'* APPROVAL 24" or DESIGN DESIGN o LA RGER AP ROVAL APPROVAL No No Yes T Yes- 24" or MH/BOX I DESIGN Yes Yes 'o a APPROVAL LARGER PI NO LARGER THAN Is- CAN BE USED IN THE 2' SIDE OF THIS BOX SPECIAL NOTE: INCOMING AND OUT GOING PIPES EFFECT STEPS IN THIS STRUCTURE STRUCTURES DEEPER THAN 1W FROM T/C TO INVERT WILL BE A M.P OR A BOX WITH STEPS UNLESS APPROVED. SPECIAL DESIGN IS APPROVED. SPECIAL NOTE: STRUCTURES WILL BE DESIGNED FOR MAXIMUM FLOW IN PIPES SPECIAL NOTE: COUNT Y MA REQUIRE STEPS To BE INSTALLED AFTER STRUCTURE IS SET, TO IMPROVE ACCESS. -1 Q NOTE: CONSTRUCTION TOLERANCE FOR YARD INLETS WILL BE +0.0' TO -0.20' DESIGN R AL NOTE: "EXCEPT FOR FORCE MAINS, CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES AND STORM SEWERS IS 18 OR LESS." ALL MANHOLES TO BE CONSTRUCTED WITH ONE 4" RISER SCALE: 1"= 50' RING (NO MORE NO LESS) TO ESTABLISH PLAN CASTING GRADE. THERE SHALL BE NO MANHOLES OR WATER VALVES WITHIN THE STREET PAVEMENT, CURBS, SIDEWALKS, OR ASPHALT PATHS F- DINIOTES FULL DEPTH GRANULAR BAIKIILL PER CITY STANDARDS NOTED ON SHEET C804 0 C-) a d V) 2 El P 2 ED RECORD DRAWING 0 LAJ GO WC�l 4 No DATE: 00012 DENNIS D. OLMSTEAD 1 0 SCALE: I"=5 HOR. 2 Re Land Surve STATEOF .1 1 =5' VERT. No. 900012 "n". P` OF THE JURISDICTION OF THE UTILITY, THE MINIMUM 17— COVER FROM THE TOP OF THE INSTALLED PAVEMENT V) TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER No CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE ­ET N. F PAVEMENT ELEVATION TO THE TOP OF THE PPE BE LESS THAN 2.5 FEET. C600 LLJ 0 Of a- (10 LJ Z V) 0 ALL EXISTING OFF-SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED I w LL_ I STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW n LIJ Z (D 0 ry NOTE: ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP TO WATERWAY". 3: LLJ cn NO WASTE-DRAINS LjJ cf) 0 NOTE: :2 FOR INSTALLATION OF STORM MAINS, WATER MAINS, WATER SERVICE LATERALS, SANIHARY ry SANITARY MAINS, SERVICE LATERALS UNDER CITY STREETS, REGARDLESS 0 OF THE JURISDICTION OF THE UTILITY, THE MINIMUM 17— COVER FROM THE TOP OF THE INSTALLED PAVEMENT V) TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER No CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE ­ET N. F PAVEMENT ELEVATION TO THE TOP OF THE PPE BE LESS THAN 2.5 FEET. C600