HomeMy WebLinkAbout036-01 C-210 SL-1 Site Lighting PlanSITE LIG POLES TO WITHSTAND 100 MPH WINDS PLUS 1.3 GUST ALL POLES SHALL BE CAPABLE OF SUPPORTING TOTAL WEIGHT AND SUSTAINING TOTAL EPA WIND LOADS AS DESCRIBED, ALL POLES SHALL BE EQUIPPED WITH VIBRATION DAMPERS, GROUND LUG. POLE BASE COVERS. AND LEVELING NUTS VENDOR COOPER COOPER COOPER HUBBELL HUBBELL HUBBELL TING POLE SCHEDULE ALUMINUM POLES (GRAY FINISH) (100 MPH WINDS) H35 (R3) "F" FIXTURE TYPE I"B35" I "H35" "Q35" "B35" I "H35" i"Q35" SITE LIGHTI THREE (1000W) LUMINAIRES MOUNTED ON B35 SEAMLESS ALUMINUM POLE. SEE POLE BASE DETAIL -THIS SHEET. BY ELECTRICAL CONTRACTOR SITE LIG TRIPLE SINGLE (1000W) TWIN 180' TRIPLE SINGLE (1000W) TWIN 0 180' \G FIXTURE SC ONE (1000W) LUMINAIRE MOUNTED ON SEAMLESS ALUMINUM POLE. SEE POLE BASE DETAIL THIS SHEET. BY ELECTRICAL CONTRACTOR TWO (1000W) (R3) DIST. W/ HOUSE SIDE (ROTATE OPTICS) LUMINAIRES MOUNTED 0 Q5 SEAMLESS ALUMINUM POLE. SEE POLE THIS SHEET BY ELECTRICAL CONTRACTOR TI \G FIXTUR POLE# AT 35' 1(P&K) RTA0X35DVM3 (P &K) RTAOL35DVM1 (P &K) RTAOM35DVM2 -47 "HAPCO" I HAPCO" HAPCO" ALL SITE LIGHTING FIXTURES SHALL BE FURNISHED INSTALLED BY THE ELECTRICAL CONTRACTOR. WIRING TO THESE SECURITY LIGHTS SHALL BE UNDERGROUND. ALL FIXTURES MOUNTED ON ALUMINUM POLES IN FRONT PARKING AREA AND REAR STORAGE YARD SHALL BE "SHOE —BOX" OR FLOOD, METAL HALIDE, EACH FIXTURE SHALL HAVE GRAY FINISH AND REMOVABLE BALLAST TRAYS OR DOORS. FIXTURES SHALL BE ONE OF THE FOLLOWING MODELS... NO SUBSTITUTIONS ALLOWED. NOTE: ALL LIGHT FIXTURES SHALL BE U.L. APPROVED. 480V.10 RTA- 0356— H2 —M53 RTA 8356 -A2 —M53 RTA- 0356 —C2 —M53 DOTES EDULE POLE MOUNTED FIXTURES "B35" —1000 w METAL HALIDE 01201035 DIST COOPER NO. GLA91125AS AP HUBBELL NO. MSV 1000H BW5 3AR5 POLE MOUNTED FIXTURES "H35" (1 -1000 W METAL HALIDE 0901 (R3 DIST.Z COOPER NO. GLA911253V AP HUBBELL NO. MSV 1000H BP5 3AR4 POLE MOUNTED FIXTURES "Q35" (2 -1000 W METAL HALIDE 0 180') (R3 DIST.) COOPER NO. GLA91125 3V HS AP (WITH HOUSE SIDE SHIELD) (ROTATE OPTICS) HUBBELL NO. MSV 1000H BP5 3AR5 W/ MSV GS 3 HAND HOLE (LOCATE FUSEHOLDER AND FUSE DIRECTLY INS /DE HAND HOLE) CONDUIT STUBS TO BE INSTALLED TO HEIGHT OF ANCHOR BOLTS POLE BASE W LE VEUNG NUTS 1 GROUT (MIN.) 18 BARE GROUND WIRE CLAMP SUITABLE FOR DIRECT BURIAL /8 BARE GROUND WIRE 3/4"0 X 10=-0' COPPER CLAD GROUNDING ROD 1°LElLY ROUND BASE 6 NO. 5 BARS ANCHOR BOLTS qx6 19/10 WWF CAGE NOTE: SHAFT CAP, ARMS, BASE FLANGE, ANCHOR BOLTS, LEVELING NUTS, CONNECTION, HARDWARE, BOLT BOTC%RLE FURN /SHED BY POLE MFGR. 18 BARE GROUND WIRE POLE GROUND LUG W/ FEMALE 1 /2''X 13 NC THREAD NOTE: POLE BASE IS TO BE ONE CONTINUOUS POUR. 2' PORTION OF EXPOSED CONC. BASE ABOVE PAVEMENT SHALL BE HAND RUBBED SMOOTH. PRE FABBED CONC. POLE BASES WILL NOT BE ACCEPTED. (ALL BASES MUST BE POURED ON SITE) SECT1OIV POLE BASE DETAILS CONCRETE BASE ELECT CONDUIT GROUND LIG/ -/T POLE PEP NEC. NOTE /1 SITE ELECTRICAL CONTR. TO COORDINATE LOCATION OF EASEMENTS, UNDERGROUND UTILITIES DRAINAGE BEFORE DRILLING POLE BASES. (TYP) POLE SHAFT POLE BASE WITH 1' GROUT GALVANIZED ANCHOR BOLTS HARDWARE 6 NO. 5 BARS WITHIN A 6x6 10/10 WWF "CAGE" MAINTAIN 3" MINIMUM CONCRETE COVERAGE ON ALL BARS NOTE: ONLY COOPER HUBBELL APPROVED FOR THIS SITE. ALLOWED) LITHONIA WILL ON ANY PORTION OF THIS FIXTURES SHALL BE (NO SUBSTITUTES NOT BE PERMITTED TO BID SITE LIGHTING PACKAGE. CONTRACTOR TO TAKE SPECIAL CARE TO ENSURE CONCRETE POLE BASES ARE POURED ABSOLUTELY VERTICAL LEVEL. FENCE OR OUTSIDE WALL OF TRUCK WELL POLE BASE SEE DETAIL GUARD POST POLE LOCATION DETAIL GUARD POST SEE DETAIL GUARD POST SEE DETAIL d a 4 4 OF PIP PAI a 1 7 8* DIA. CONC. FILLED PIPE GUARD POST DETAIL CONCRETE TOP SMOOTH NT OSHA YELLOW PAVING CONCRETE FOUNDATION 1 i i i 1 1 1 1 0 1 1 1 of 1 z 37 T vl 0 a 1 1 NO4E# 1 (i35 1 0 NL I UNDERGROUND CIRCUIT 4H— 49,51,53 9.1 A 0 480 V., 3 0 CONTROLLED BY EMS UNDERGROUND CIRCUIT 4H— 57,59 6.8 A 480 V., 1 0 NIGHT LIGHT CIRCUIT 035 .p,4b'"NOTE# 1 45 FOOT SETBACK N OTE #3 LOWE'S STORE 139,000 80. Fr. UNDERGROUND CIRCUIT 2H— 49,51,53 7.8 A 0 480 V., 3 0 CONTROLLED BY EMS UNDERGROUND CIRCUIT 2H— 50,52 6.8 A c 480 V., 1 0 NIGHT LIGHT CIRCUIT RETAINING WALL 75 FOOT (23 METER) R.O.W. AB NL NL B35 CA NOTE# 1 UNDERGROUND CIRCUIT 114-59,61 9.0 A 0 480 V., 10 CONTROLLED BY EMS UNDERGROUND CIRCUIT 1H-63,65 9.0 A 0 480 V., 1 0 NIGHT LIGHT CIRCUIT UNDERGROUND CIRCUIT 2H— 55,57,59 9.1 A 480 V., 3 0 CONTROLLED BY EMS UNDERGROUND CIRCUIT 214— 54,56 6.8 A 480 V., 1 0 NIGHT LIGHT CIRCUIT NOTE #2 146th STREET .100. 101111. (5) #8 IN 1"C 11 BC UNDERGROUND CIRCUIT 2H -63,65 11.3 A 0 480 V., 10 CONTROLLED BY EMS UND GROUND CI C IT 2H 58,60 6.: A 0 480 V., 1 0 H LIGHT CIRCUIT El 1E3 SITE LIGHTING PLAN SCALE 1 =60' 035 r GENERAL NOTES SITE ELECTRICAL CONTRACTOR TO COORDINATE LOCATION OF EASEMENTS, UNDERGROUND UTILITIES DRAINAGE BEFORE DRILLING POLE BASES. (TYPICAL) 2. NL INDICATES THIS LUMINAIRE SHALL BE ON A NIGHT LIGHT CIRCUIT (TYPICAL). 3. THESE DESIGNATIONS INDICATE WHAT PHASE LIGHTS ARE WIRED TO (TYPICAL). 4. FL INDICATES THIS LUMINAIRE SHALL BE A FLOOD LIGHT FIXTURE. MOUNTING BRACKET FOR THIS FL FIXTURE SHALL BE MOUNTED 25' ABOVE BOTTOM OF POLE BASE (TYPICAL) FOR ALL LIGHT POLES CLOSET TO STOREFRONT. 1. S- EXTEND A 480/277V., 3 0 SERVICE TO LOWE'S ROAD SIGN. INSTALL A 30A 3P NEMA 3R DISC. SWITCH (EACH LEG FUSED 20A.) SIGN REQUIRES (3) 20A 277V. CIRCUITS. 6. PROVIDE PROTECTIVE GUARD POST AT THESE LIGHT POLE BASES. LOCATE GUARD POST AS SHOWN ON DETAIL. SEE DETAIL THIS SHEET.(IF APPLICABLE) 0 (5) #8 IN 1 "C 0 NL i B35 BC o A NL s o-Is NOTE# 1 L N NOTE #6 i C 35 O E #1 NL NL 8383 X 831.53 838dtch X 829.77 match 1\ 035 035 1 035 a I cf rn LOWE'S ROAD SIGN CIRCUIT 2E- 20,22,24 NOTE #5 CM Sl01 08/08/00 (1/80) S t' co DATE LOWE'S COMPANIES, INC. AUGUST, 2000 COPYRIGHT ALL RIGHTS RESERVED z� o 0 SHEET REVISIONS PRE—BID SET ISSUE DATE Q POST BID SET ISSUE DATE 0 1 U DESCRIPTION SL -1 OF 1 L tn 0 w IL/ I tZ co o N d' I Z O I O M W z oi .h ca co W K3 I- M CO 00 M CL C -210