Loading...
HomeMy WebLinkAbout036-01 C-400 Storm Sewer Plan & Profilei MIES 111111111= 11111111NEIN 11111111: iig14 IIIIIIIIIIIIIIIIIII 11111 millyil MIME �III� I ll ,11F4114.41111111111111111111111111111111/ i11.� ■v�rt INN 23fi o RC 101 riallmili Mil II ME MS PRE —BID SET ISSUE DATE POST BID SET ISSUE DATE N 0 0 0 10 +0 STORM SEWER PLAN AND PROFILE (VOTES 1. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART "P" APLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. 2. IN ADDITION, EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. 3. ALL STRUCTURES SHALL HAVE CASTINGS, JOINTS, LIFT RINGS, STEPS AND PIPE CONNECTIONS WELL GROUTED, TROWELED SMOOTH AND BRUSH FINISHED. 4. ALL MANHOLES SHALL HAVE POURED FLOW LINES AND BENCH WALLS. THE FLOW LINES AND BENCHWALLS SHALL BE TROWELED SMOOTH AND BRUSH FINISHED. 5. FIELD ADJUSTMENTS OF TOP OF CASTING (T C.) OF STRUCTURES MAYBE REQUIRED TO MEET FIELD CONDITIONS. ADJUSTMENTS EXCEEDING FIVE TENTHS (0.5) OF A FOOT MUST BE APPROVED BY THE ENGINEER TO DETERMINE THE INTEGRITY OF THE STRUCTURE. AT NO COST TO THE OWNER. 6. STORM STRUCTURES WITH INLET CASTINGS SHALL BE SET TO MAINTAIN A POSITIVE DRAINAGE FLOW INTO THE STRUCTURE. 7. STORM PIPE INVERTS AT OUTLET STRUCTURES OE: END SECTIONS), AND PIPE LENGTHS MAY REQUIRE FIELD ADJUSTMENTS TO MEET ACTUAL FIELD CONDITIONS. 8. FULL DEPTH GRANULAR BACKFILL SHALL BE REQUIRED UNDER AND WITHIN FIVE (5) FEET OF ALL PAVED AREAS, INCLUDING CURBS, EDGE OF PAVEMENT, AND SIDEWALKS. SEE DETAILS SHEET C604. 11 9. SEE SECTION 02720 FOR STORM SEWERAGE SPECIFICATIONS 10. PIPES LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE END SECTIONS. 11. UTILITY CONTRACTOR SHALL PROVIDE 3"x 3 x 8" THICK CONCRETE APRON AT ALL CLEANOUTS OUTSIDE OF BUILDING 12. ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPES IN ACCORDANCE TO ASTM 76 CLASS 111. 13. ALL DRAINAGE STRUCTURES AND STORM SEWER PIPES SHALL MEET HEAVY DUTY TRAFFIC LOADING AND BE INSTALLED ACCORDINGL Y. oa f Stm. Str. #32 12 +00 0 13 +00 VV'E 14+00 0 160 lft, 4816 RCP Cio• V00.10% 0L. tn d SIDE OF I OWES 15 +00 16 +00 Stm Str. D tm. Str. #18 17+00 zsbe ^,w 18 +00 LOWE'S STORE 135,197 SO. FT. 19+00 20 +00 21 +00 Stm, Str.#14 110 /fL 24 "0 for Downspouts 0 0.144 Stm. Str.#30 Stm. Str, #15 Stm. Str, #10 z 0 MEM MEW NSW 50 0 25 50 100 nanieliiiiMTniMli 5 Scale: 1"=- 50' Scale: 1"= (Horz.) (Vert.) 22 +00