Loading...
HomeMy WebLinkAbout036-01 C-402 Storm Sewer Plan & ProfileStm, Str. #11 LFt. 30 "0 R ss -V 0 x,10 Stm. Str. #31 RETENTION Inv. El. 813.56 POND 1 822.0 823.0 Stm, Str, #32 Stm, Str.,#10 822.0 44 1ft. 15 "0 R Class -11I 0 1.8 821.0- 1 Stm. Str. #1 823.0 t. 15 "0 RC 821.0 821.0- 820.0 821.0 2 x 190 1 ft. 30 "0 RCP MID -LINE OF LOWES Stm. Str. #24 821.0 Stm. Str. #23 Stm. Str. #2 Stm. Str. Inv. El. 81 821.0 08 Stm. Str. #21 Inv. El. Out 810.93 NORTH 312 Ift. 48 "0 RCP 0 0.30% 1. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART 'P "APL /ES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. 2. IN ADDITION, EXCAVATIONS EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. 3. ALL STRUCTURES SHALL HAVE CASTINGS, JOINTS, LIFT RINGS, STEPS AND PIPE CONNECTIONS WELL GROUTED, TROWELED SMOOTH AND BRUSH FINISHED. 4. ALL MANHOLES SHALL HAVE POURED FLOW LINES AND BENCH WALLS. THE FLOW LINES AND BENCHWALLS SHALL BE TROWELED SMOOTH AND BRUSH FINISHED. 5. FIELD ADJUSTMENTS OF TOP OF CASTING (T. C.) OF STRUCTURES MAY BE REQUIRED TO MEET FIELD CONDITIONS ADJUSTMENTS EXCEEDING FIVE TENTHS (0.5) OF A FOOT MUST BE APPROVED BY THE ENGINEER TO DETERMINE THE INTEGRITY OF THE STRUCTURE. AT NO COST TO THE OWNER. 6. STORM STRUCTURES WITH INLET CASTINGS SHALL BE SET TO MAINTAIN A POSITIVE DRAINAGE FLOW INTO THE STRUCTURE. 7 STORM PIPE INVERTS AT OUTLET STRUCTURES (IE; END SECTIONS), AND PIPE LENGTHS MAY REQUIRE FIELD ADJUSTMENTS TO MEET ACTUAL FIELD CONDITIONS, 8. FULL DEPTH GRANULAR BACKFILL SHALL BE REQUIRED UNDER AND WITHIN FIVE (5) FEET OF ALL PAVED AREAS, INCLUDING CURBS, EDGE OF PAVEMENT, AND SIDEWALKS. SEE DETAILS SHEET C604. 9. SEE SECTION 02720 FOR STORM SEWERAGE SPECIFICATIONS 10. PIPES LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE END SECTIONS 11. UTILITY CONTRACTOR SHALL PROVIDE 3x 3`x 8" THICK CONCRETE APRON AT ALL CLEANOUTS OUTSIDE OF BUILDING. 12. ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPES IN ACCORDANCE TO ASTM -C -76 CLASS Ill. 13. ALL DRAINAGE STRUCTURES AND STORM SEWER PIPES SHALL MEET HEAVY DUTY TRAFFIC LOADING AND BE INSTALLED ACCORDINGL Y. Stm. Str. #38 Inv, El, 810.00 (TO POND) Scale: 1"= 50' (Horz.) 5 Scale: 1"= (Vert.) DESCRIPTION 44 L,Ft, 15 "0 RCP Class 111 0 1,80'0 Inv. El. 878.00 MI MIR TJPIIIIIIIIIIIINNIEAII Mai. 1111111111111MMIIIIIIIIIIMIIIMIIIII 1111111111111111=111.111MiasillinilliMIIIIIiiiiiIMEI 1111111111WWW111111111107=M111 ,11111111111111MilliMMIIIIMINENIM iiiiirralertmeminimimm 1 11 immi:.....w.gemarikikasitu iiiimmmirmil 1113..... JAIIIIIIIIMIMMilli I: 111111111 II 111111111adoadinex■ immlinuma i mum illimm 24 L. Ft. 15 RCP Class- V Pro G ode 10+00 11+00 12 +00 13+00 14+00 15 +00 16 +00 �I N1(1 J I 4. 7c2: i M 18206 Inhi1 1 r, C3 STATff 7 latliV,14rg.w3t, 1 4 4, AL At. t4 t ,..ar� SHEET REVISIONS O PRE -BID SET ISSUE DATE POST BID SET ISSUE DATE C -402 CSI PROJ. #00 113